Confocal 3D Optical Intraoral Scanners and Comparison of Image Capturing Accuracy

被引:27
|
作者
Amornvit, Pokpong [1 ]
Rokaya, Dinesh [1 ]
Peampring, Chaimongkon [1 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2021年 / 66卷 / 01期
关键词
Confocal; intraoral scanners; accuracy; 3-dimensional analysis; teeth analysis; digital;
D O I
10.32604/cmc.2020.011943
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Several capture techniques are used in intraoral optical scanners in the dental market, such as Triangulation (Cerec Omnicam, Dentsply Sirona), Activewave front sampling (3M ESPE) and confocal technology (iTero, Align). The accuracy of intraoral scanners is the most significant focal point for developers to research. This in-vitro study studied the accuracy of confocal scanners launched from 2015-2020 (Trios 3, Trios 4, iTero Element; 3Shape Trios A/S, Copenhagen, Denmark, and iTero Element2, and iTero Element5D; Align Technologies, San Jose, CA, USA). A 3D printing model modified from the American National Standard No. 132 was scanned five times each scanner. Both Trios3 and Trios4 were scanned using regular scan mode (N) and high-resolution mode (HR). All scanning methods followed the recommendations from the manufacturers. Then the digital models were exported and saved as STL files. Various measurements were determined in the digital model from each scan using Rhinoceros 3D Software (Rhino, Robert McNeel & Associates for Windows, Washington DC, USA). Measurements from the 3D printed model were used as control. All data were recorded in Microsoft Excel and then transferred to SPSS. Descriptive statistics were recorded. Multiple comparisons of various measurements were made among the different scanners and with the control using One-way ANOVA and post hoc using Sheffe (p < 0.01). The surface area in the X and Y axis ranged from 2-60 mm, while the depth (Z-axis) ranged from 2-8 mm. The Trios and iTero families showed similar accuracy. However, for the diagonal, the Trios series showed better results compared with the iTero series. Within the same brand, different versions showed no significant change regarding accuracy.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 50 条
  • [1] An in vitro 3D evaluation of the accuracy of 4 intraoral optical scanners on a 6-implant model
    Sami, Toni
    Goldstein, Gary
    Vafiadis, Dean
    Absher, Taylor
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06): : 748 - 754
  • [2] Evaluation of the accuracy of 2 digital intraoral scanners: A 3D analysis study
    Alzahrani, Saeed J.
    EL-Hammali, Hind
    Morgano, Steven M.
    Elkassaby, Heba
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (06): : 787 - 792
  • [3] Comparison of Optical and Laser 3D Scanners
    Toth, Teodor
    Rajt'ukova, Viktoria
    Zivcak, Jozef
    14TH IEEE INTERNATIONAL SYMPOSIUM ON COMPUTATIONAL INTELLIGENCE AND INFORMATICS (CINTI), 2013, : 79 - 82
  • [4] Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressions
    Akkal, Ozcan
    Korkmaz, Ismail Hakki
    Bayindir, Funda
    JOURNAL OF ADVANCED PROSTHODONTICS, 2023, 15 (04): : 179 - 188
  • [5] Comparative analysis of intraoral scanners accuracy using 3D software: an in vivo study
    Federica Pellitteri
    Paolo Albertini
    Angelica Vogrig
    Giorgio Alfredo Spedicato
    Giuseppe Siciliani
    Luca Lombardo
    Progress in Orthodontics, 23
  • [6] Comparative analysis of intraoral scanners accuracy using 3D software: an in vivo study
    Pellitteri, Federica
    Albertini, Paolo
    Vogrig, Angelica
    Spedicato, Giorgio Alfredo
    Siciliani, Giuseppe
    Lombardo, Luca
    PROGRESS IN ORTHODONTICS, 2022, 23 (01)
  • [7] A comparison of the accuracy of intraoral scanners using an intraoral environment simulator
    Park, Hye-Nan
    Lim, Young-Jun
    Yi, Won-Jin
    Han, Jung-Suk
    Lee, Seung-Pyo
    JOURNAL OF ADVANCED PROSTHODONTICS, 2018, 10 (01): : 58 - 64
  • [8] Comparison of Accuracy of Current Ten Intraoral Scanners
    Amornvit, Pokpong
    Rokaya, Dinesh
    Sanohkan, Sasiwimol
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [9] Assessment of Compatibility between Various Intraoral Scanners and 3D Printers through an Accuracy Analysis of 3D Printed Models
    Im, Chang-Hee
    Park, Ji-Man
    Kim, Jang-Hyun
    Kang, You-Jung
    Kim, Jee-Hwan
    MATERIALS, 2020, 13 (19) : 1 - 16
  • [10] Studying the Optical 3D Accuracy of Intraoral Scans: An In Vitro Study
    Amornvit, Pokpong
    Sanohkan, Sasiwimol
    Peampring, Chaimongkon
    JOURNAL OF HEALTHCARE ENGINEERING, 2020, 2020 (2020)