Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator

被引:94
|
作者
Ding, YJ
Ma, GY
Chai, QH
Yi, JA [1 ]
机构
[1] Tsing Hua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Tsing Hua Univ, Dept Thermal Engn, Beijing 100084, Peoples R China
[3] Beijing Polytech Univ, Sch Energy & Environm, Beijing 100022, Peoples R China
关键词
heat pump; air source; experiment; defrosting; reverse cycle; expansion valve;
D O I
10.1016/j.ijrefrig.2004.01.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Reverse-cycle defrosting technique is one of the simplest and most widely used defrosting methods for air source heat pumps (ASHP). However, there are still some problems if thermal expansive valve (TXV) is used as throttle regulator in the unit: the defrosting process might last so long that users would feel uncomfortable due to the fluctuation of the indoor temperature: the system cannot resume heating mode smoothly after the defrosting process, the system often breaks down due to the triggering of low-pressure switch. In this paper the authors proposed that these two problems can be greatly relieved if there is a by-pass solenoid valve in the system which can by-pass the TXV used in the defrosting mode, and best performance can be addressed if the by-pass valve is energized during the whole defrosting process. (C) 2004 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:671 / 678
页数:8
相关论文
共 50 条
  • [41] Review on improvement for air source heat pump units during frosting and defrosting
    Song Mengjie
    Deng Shiming
    Dang Chaobin
    Mao Ning
    Wang Zhihua
    APPLIED ENERGY, 2018, 211 : 1150 - 1170
  • [42] Investigation of defrosting water retention on the surface of evaporator impacting the performance of air source heat pump during periodic frosting-defrosting cycles
    Li, L. T.
    Wang, W.
    Sun, Y. Y.
    Feng, Y. C.
    Lu, W. P.
    Zhu, J. H.
    Ge, Y. J.
    APPLIED ENERGY, 2014, 135 : 98 - 107
  • [43] Experimental and theoretical investigation on defrosting characteristics of a multi-split air source heat pump with vapor injection
    Wei, Wenzhe
    Ni, Long
    Wang, Wei
    Yao, Yang
    ENERGY AND BUILDINGS, 2020, 217 (217)
  • [44] A novel defrosting method using heat energy dissipated by the compressor of an air source heat pump
    Long, Zhang
    Dong Jiankai
    Jiang Yiqiang
    Yang, Yao
    APPLIED ENERGY, 2014, 133 : 101 - 111
  • [45] Comparison of dynamic characteristics between the hot-gas bypass defrosting method and reverse-cycle defrosting method on an air-to-water heat pump
    Huang, Dong
    Yuan, Xiuling
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2006, 40 (05): : 539 - 543
  • [46] Experimental investigation of an Air Source Heat Pump
    Talpiga, Mugurel Florin
    Iordache, Florin
    Mandric, Eugen
    SUSTAINABLE SOLUTIONS FOR ENERGY AND ENVIRONMENT (EENVIRO 2018), 2019, 85
  • [47] Experiment study on performance of air source heat pump
    Shi, Weixiu
    Pan, Lisheng
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 645 - +
  • [48] Operating characteristics of an air-source heat pump under frosting/defrosting conditions
    He, Z
    Peng, X
    Xing, Z
    Shu, P
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2003, 217 (A6) : 623 - 629
  • [49] Analysis of Air-Source Heat Pump System Based on Energy Storage for Defrosting
    Liu, Xuelai
    Zhang, Hongrui
    Wang, Lei
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [50] Improving the frosting and defrosting performance of air source heat pump units: review and outlook
    Song M.
    Dong J.
    Wu C.
    Jiang Y.
    Qu M.
    Wu, Chili (chiliwu@ust.hk), 1600, Taylor and Francis Asia Pacific (24): : 88 - 98