Experiment investigation of reverse cycle defrosting methods on air source heat pump with TXV as the throttle regulator

被引:94
|
作者
Ding, YJ
Ma, GY
Chai, QH
Yi, JA [1 ]
机构
[1] Tsing Hua Univ, Dept Bldg Sci, Beijing 100084, Peoples R China
[2] Tsing Hua Univ, Dept Thermal Engn, Beijing 100084, Peoples R China
[3] Beijing Polytech Univ, Sch Energy & Environm, Beijing 100022, Peoples R China
关键词
heat pump; air source; experiment; defrosting; reverse cycle; expansion valve;
D O I
10.1016/j.ijrefrig.2004.01.008
中图分类号
O414.1 [热力学];
学科分类号
摘要
Reverse-cycle defrosting technique is one of the simplest and most widely used defrosting methods for air source heat pumps (ASHP). However, there are still some problems if thermal expansive valve (TXV) is used as throttle regulator in the unit: the defrosting process might last so long that users would feel uncomfortable due to the fluctuation of the indoor temperature: the system cannot resume heating mode smoothly after the defrosting process, the system often breaks down due to the triggering of low-pressure switch. In this paper the authors proposed that these two problems can be greatly relieved if there is a by-pass solenoid valve in the system which can by-pass the TXV used in the defrosting mode, and best performance can be addressed if the by-pass valve is energized during the whole defrosting process. (C) 2004 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:671 / 678
页数:8
相关论文
共 50 条
  • [31] Experimental study of solution defrosting characteristics of air source heat pump
    Jiang, Ping
    Zhang, Yu
    Fan, Hongxiu
    Jin, Qi
    Yu, Yanshun
    APPLIED THERMAL ENGINEERING, 2024, 236
  • [32] Experimental investigation of heating performance of air source heat pump with stable heating capacity during defrosting
    Liang, Chenjiyu
    Li, Xianting
    Meng, Xiangjun
    Shi, Wenxing
    Gu, Junqiang
    Wang, Baolong
    Lv, Yanbo
    APPLIED THERMAL ENGINEERING, 2023, 235
  • [33] Effect of PCM based heat exchanger for defrosting on performance of air source heat pump
    School of Municipal and Environment, Harbin Institute of Technology, Harbin 150090, China
    Tianjin Daxue Xuebao (Ziran Kexue yu Gongcheng Jishu Ban), 2009, 10 (908-912):
  • [34] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part II: Modeling analysis
    Qu, Minglu
    Pan, Dongmei
    Xia, Liang
    Deng, Shiming
    Jiang, Yiqiang
    APPLIED ENERGY, 2012, 91 (01) : 274 - 280
  • [35] Experimental analysis of heat coupling during TES based reverse cycle defrosting method for cascade air source heat pumps
    Qu Minglu
    Zhang Rao
    Chen Jianbo
    Cheng Yuanda
    Zhao Xudong
    Zhang Tongyao
    Li Zhao
    RENEWABLE ENERGY, 2020, 147 : 35 - 42
  • [36] Experimental Study on Characteristics of False defrosting for Split Air Source Heat Pump
    Tang, Ruichao
    Han, Zhitao
    Zhang, Erkang
    Liu, Shuguang
    Zhang, Haiquan
    Su, Yuchang
    Wang, Songqing
    ADVANCES IN MANUFACTURING TECHNOLOGY, PTS 1-4, 2012, 220-223 : 585 - 591
  • [37] Transient simulation of air-source heat pump during the reverse cycle defrost
    Liu, ZQ
    Tang, GF
    Zhao, FY
    CRYOGENICS AND REFRIGERATION - PROCEEDINGS OF ICCR'2003, 2003, : 695 - 698
  • [38] An experimental study on the effects of downwards flowing of melted frost over a vertical multi-circuit outdoor coil in an air source heat pump on defrosting performance during reverse cycle defrosting
    Song, Mengjie
    Deng, Shiming
    Pan, Dongmei
    Mao, Ning
    APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 258 - 265
  • [39] The optimal defrosting condition of an air source heat pump based on entropy analysis
    Dong, Wei
    Li, Yongcun
    Zou, Shenghua
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 13176 - 13195
  • [40] Energy transfer procession in an air source heat pump unit during defrosting
    Song Mengjie
    Xu Xiangguo
    Mao Ning
    Deng Shiming
    Xu Yingjie
    APPLIED ENERGY, 2017, 204 : 679 - 689