27-gauge trocar-assisted sutureless intraocular lens fixation

被引:15
|
作者
Jujo, Tatsuya [1 ]
Kogo, Jiro [1 ]
Sasaki, Hiroki [1 ]
Sekine, Reio [1 ]
Sato, Keiji [1 ]
Ebisutani, Sakura [1 ]
Toyoda, Yasuhiro [1 ]
Kitaoka, Yasushi [1 ]
Takagi, Hitoshi [1 ]
机构
[1] St Marianna Univ, Dept Ophthalmol, Sch Med, Miyamae Ku, 2-16-1 Sugao, Kawasaki, Kanagawa, Japan
关键词
Sutureless intraocular lens fixation; 27-gauge trocar; Flange technique; 27G vitrectomy; CASIA2;
D O I
10.1186/s12886-020-01758-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundsHowever there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar.MethodsNineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o'clock, 2mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications.ResultsThe 19 eyes were followed up for 1month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.060.63 and 0.40 +/- 0.26, respectively (p<0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27<plus/minus>0.51 and 0.06 +/- 0.15, respectively (p=0.09). The mean corneal endothelial cell density was 2406 +/- 625 to 2004 +/- 759 cells/mm(2) at 1month (p=0.13). The mean IOL tilt was 3.52 +/- 3.00 degrees, and the mean IOL decentration was 0.39 +/- 0.39mm. There was no correlation among IOL tilt, decentration and BCVA (p>0.05). The mean prediction error of the target refraction was -0.03 +/- 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred.Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-Assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 : 39 - 43
  • [32] A comparative study of transscleral sutured intraocular lens fixation and sutureless flanged intraocular lens fixation
    Ying Cui
    Qiyan Li
    Xiangyu Shi
    Dan Zhou
    BMC Ophthalmology, 23
  • [33] Sutureless Intrascleral Intraocular Lens Fixation Using a Microtube-assisted Technique
    Yuda, Kentaro
    Shimizu, Toshiki
    Hayashi, Takahiko
    Yuda, Kenji
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [34] A comparative study of transscleral sutured intraocular lens fixation and sutureless flanged intraocular lens fixation
    Cui, Ying
    Li, Qiyan
    Shi, Xiangyu
    Zhou, Dan
    BMC OPHTHALMOLOGY, 2023, 23 (01)
  • [35] Novel Technique for 27-Gauge Forceps-Assisted Transscleral Refixation of the Dislocated CZ70BD Intraocular Lens
    Yip, Lai Ting
    Fong, Angie
    Tsang, Chi Wai
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (10): : 1807 - 1810
  • [36] Outcomes of transconjunctival sutureless 27-gauge vitrectomy with silicone oil infusion
    Okan Toygar
    Cindy W. Mi
    Daniel M. Miller
    Christopher D. Riemann
    Graefe's Archive for Clinical and Experimental Ophthalmology, 2016, 254 : 2111 - 2118
  • [37] 27-gauge sutureless vitrectomy under topical anesthesia: A pilot study
    Adamiec-Mroczek, Joanna
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2021, 30 (10): : 1099 - 1103
  • [38] Outcomes of transconjunctival sutureless 27-gauge vitrectomy with silicone oil infusion
    Toygar, Okan
    Mi, Cindy W.
    Miller, Daniel M.
    Riemann, Christopher D.
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2016, 254 (11) : 2111 - 2118
  • [39] A 27-Gauge Instrument System for Transconjunctival Sutureless Microincision Vitrectomy Surgery
    Oshima, Yusuke
    Wakabayashi, Taku
    Sato, Tatsuhiko
    Ohji, Masahito
    Tano, Yasuo
    OPHTHALMOLOGY, 2010, 117 (01) : 93 - U122
  • [40] Endoscope-Assisted Sutureless Intrascleral Haptic Fixation of a Posterior Chamber Intraocular Lens
    Tandias, Rachel
    Lemire, Colin A.
    Yu, Gina
    Seto, Brendan
    Arroyo, Jorge G.
    JOURNAL OF VITREORETINAL DISEASES, 2022, 6 (04) : 290 - 294