27-gauge trocar-assisted sutureless intraocular lens fixation

被引:15
|
作者
Jujo, Tatsuya [1 ]
Kogo, Jiro [1 ]
Sasaki, Hiroki [1 ]
Sekine, Reio [1 ]
Sato, Keiji [1 ]
Ebisutani, Sakura [1 ]
Toyoda, Yasuhiro [1 ]
Kitaoka, Yasushi [1 ]
Takagi, Hitoshi [1 ]
机构
[1] St Marianna Univ, Dept Ophthalmol, Sch Med, Miyamae Ku, 2-16-1 Sugao, Kawasaki, Kanagawa, Japan
关键词
Sutureless intraocular lens fixation; 27-gauge trocar; Flange technique; 27G vitrectomy; CASIA2;
D O I
10.1186/s12886-020-01758-6
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundsHowever there have been numerous investigations of intrascleral intraocular lens (IOL) fixation techniques, there is room for improvement in terms of simplifying complicated techniques and reducing the high levels of skill required. This study aimed to report a novel technique for sutureless intrascleral fixation of the IOL using retinal forceps with a 27-gauge trocar.MethodsNineteen eyes of 18 patients underwent intrascleral fixation of the IOL from July 2018 to September 2019 were enrolled in this study. A 27-gauge trocar formed 3-mm scleral tunnels positioned at 4 and 10 o'clock, 2mm from the corneal limbus. We used a 3-piece IOL haptic grasped by a 27-gauge retinal forceps and pulled from the 27-gauge trocar. The IOL was fixed by making a flange. Main outcome measures were visual acuity, corneal endothelial cell density, IOL tilt, decentration, predicted error of refraction and complications.ResultsThe 19 eyes were followed up for 1month. The mean pre- and postoperative logMAR uncorrected visual acuity (UCVA) was 1.060.63 and 0.40 +/- 0.26, respectively (p<0.01), while the mean pre- and postoperative logMAR best corrected visual acuity (BCVA) was 0.27<plus/minus>0.51 and 0.06 +/- 0.15, respectively (p=0.09). The mean corneal endothelial cell density was 2406 +/- 625 to 2004 +/- 759 cells/mm(2) at 1month (p=0.13). The mean IOL tilt was 3.52 +/- 3.00 degrees, and the mean IOL decentration was 0.39 +/- 0.39mm. There was no correlation among IOL tilt, decentration and BCVA (p>0.05). The mean prediction error of the target refraction was -0.03 +/- 0.93 D. The complications were vitreous hemorrhage (3 eyes), hyphema (1 eye), IOP elevation (1 eye), iris capture of the IOL (1 eye) and hypotony (2 eyes). No IOL dislocation occurred.Conclusions IOL intrascleral fixation with a flange achieved good IOL fixation and visual outcome in the scleral tunnels created with the 27-gauge trocar.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Extraocular Technique of Intrascleral Intraocular Lens Fixation Using a Pair of the Shaft-Bended 27-Gauge Needles
    Maruko, Ichiro
    Koizumi, Hideki
    Kogure-Katakura, Akiko
    Iida, Tomohiro
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (01): : 191 - 193
  • [22] Sutureless Trocar-Cannula-Based Transconjunctival Flanged Intrascleral Intraocular Lens Fixation
    Walsh, Mark K.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2017, 37 (11): : 2191 - 2194
  • [23] 27-GAUGE SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENSES WITH HAPTIC FLANGING Short-Term Clinical Outcomes and a Disinsertion Force Study
    Stem, Maxwell S.
    Wa, Christianne A.
    Todorich, Bozho
    Woodward, Maria A.
    Walsh, Mark K.
    Wolfe, Jeremy D.
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2019, 39 (11): : 2149 - 2154
  • [24] Novel trocar assisted intraocular lens and capsular bag complex fixation
    Parkash, Rohit Om
    Gurnani, Bharat
    Kaur, Kirandeep
    Parkash, Tushya Om
    Vajpayee, Rasik B.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2024, 34 (02) : 583 - 588
  • [25] Outcomes of transconjunctival sutureless 27-gauge vitrectomy for vitreoretinal diseases
    Li, Jie
    Liu, San-Mei
    Dong, Wen-Tao
    Li, Fang
    Zhou, Cai-Hong
    Xu, Xiao-Dan
    Zhong, Jie
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2018, 11 (03) : 408 - 415
  • [26] Trocar-assisted extraocular technique for intrascleral intraocular lens fixation using a 90°-curved forceps: a modified extraocular forceps-guided technique
    Kisanuki, Yuki
    Asano, Yasuhiko
    Tomoyori, Eiji
    Onda, Hidetoshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2024, 68 (05) : 538 - 547
  • [27] Combined Femtosecond Laser-Assisted Cataract Surgery and 27-Gauge Transconjunctival Sutureless Vitrectomy
    Yilmaz, Sami
    Avci, Remzi
    Yildiz, Aysegul Mavi
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [28] INTRAOCULAR LENS MALPOSITION AFTER SUTURELESS INTRASCLERAL FIXATION OF INTRAOCULAR LENS
    Byun, Zeeyoon
    Kong, Mingui
    Son, Gisung
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2022, 42 (01): : 64 - 72
  • [29] Outcomes of transconjunctival sutureless 27-gauge vitrectomy for vitreoretinal diseases
    Jie Li
    San-Mei Liu
    Wen-Tao Dong
    Fang Li
    Cai-Hong Zhou
    Xiao-Dan Xu
    Jie Zhong
    International Journal of Ophthalmology, 2018, (03) : 408 - 415
  • [30] Trocar blade-assisted scleral fixation for an incomplete dislocated intraocular lens
    Liu, Laura
    Wang, Nan-Kai
    Chen, Yen-Po
    Chen, Kuan-Jen
    Chou, Hung-Da
    Kang, Eugene Yu-Chuan
    Yeung, Ling
    Hwang, Yih-Shiou
    Chen, Tun-Lu
    Chen, Yi-Hsing
    Wu, Wei-Chi
    Lai, Chi-Chun
    Liu, Jorn-Hon
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2021, 47 (11): : E40 - E43