A novel enzymatic glucose biosensor and sensitive non-enzymatic hydrogen peroxide sensor based on graphene and cobalt oxide nanoparticles composite modified glassy carbon electrode

被引:112
|
作者
Karuppiah, Chelladurai [1 ]
Palanisamy, Selvakumar [1 ]
Chen, Shen-Ming [1 ]
Veeramani, Vediyappan [1 ]
Periakaruppan, Prakash [2 ]
机构
[1] Natl Taipei Univ Technol, Dept Chem Engn & Biotechnol, Taipei 106, Taiwan
[2] Thiagarajar Coll, Post Grad & Res Dept Chem, Madurai 625009, Tamil Nadu, India
来源
关键词
Graphene; Cobalt oxide nanoparticles; Glucose oxidase; Direct electrochemistry; Glucose biosensor; Non-enzymatic hydrogen peroxide sensor; DIRECT ELECTROCHEMISTRY; PERFORMANCE; REDUCTION; OXIDATION;
D O I
10.1016/j.snb.2014.02.034
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In the present study, we have demonstrated the fabrication of novel enzymatic glucose biosensor using glucose oxidase (GOD) as a model enzyme which has been immobilized onto the graphene (GF) and cobalt oxide nanoparticles (Co3O4-NPs) composite modified electrode. The GF/Co3O4-NPs composite was prepared by hydrothermal method and characterized by using scanning electron microscopy, X-ray diffraction and elemental analysis. The GOD immobilized GF/Co3O4-NPs modified electrode shows a well defined redox behaviour indicating the reversible proton and electron transfer reaction of GOD. A heterogeneous electron transfer rate constant (K-s) of immobilized GOD has been calculated to be 3.52 s(-1) which is much higher than that of GOD immobilized GF supports. The fast electron transfer of GOD is attributed to the excellent biocompatibility of Co3O4-NPs and high conductivity of the GF. The fabricated glucose biosensor exhibits a wider linear response for glucose from 0.5 mM to 16.5 mM with the sensitivity of 13.52 mu A mM(-1) cm(-2). In addition, a non-enzymatic H2O2 sensor has been further developed using GF/Co3O4-NPs composite modified electrode. The GF/Co3O4-NPs composite electrode shows an excellent electrocatalytic activity towards H2O2 with the response time of <10 s. The H2O2 response at GF/Co3O4-NPs composite modified electrode displays a linear response ranging from 0.2 to 211.5 mu M with a limit of detection of 0.06 mu M. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 50 条
  • [1] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Cong Zhang
    Haohai Jiang
    Rui Ma
    Yanyan Zhang
    Qiang Chen
    Ionics, 2017, 23 : 1309 - 1317
  • [2] Simple non-enzymatic electrochemical sensor for hydrogen peroxide based on nafion/platinum nanoparticles/reduced graphene oxide nanocomposite modified glassy carbon electrode
    Zhang, Cong
    Jiang, Haohai
    Ma, Rui
    Zhang, Yanyan
    Chen, Qiang
    IONICS, 2017, 23 (05) : 1309 - 1317
  • [3] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Huaan Zhong
    Ruo Yuan
    Yaqin Chai
    Yu Zhang
    Chengyan Wang
    Feng Jia
    Microchimica Acta, 2012, 176 : 389 - 395
  • [4] Non-enzymatic hydrogen peroxide amperometric sensor based on a glassy carbon electrode modified with an MWCNT/polyaniline composite film and platinum nanoparticles
    Zhong, Huaan
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Yu
    Wang, Chengyan
    Jia, Feng
    MICROCHIMICA ACTA, 2012, 176 (3-4) : 389 - 395
  • [5] A reagentless non-enzymatic hydrogen peroxide sensor presented using electrochemically reduced graphene oxide modified glassy carbon electrode
    Mutyala, Sankararao
    Mathiyarasu, Jayaraman
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 69 : 398 - 406
  • [6] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Jiang, Bin-Bin
    Wei, Xian-Wen
    Wu, Fang-Hui
    Wu, Kong-Lin
    Chen, Le
    Yuan, Guo-Zan
    Dong, Chao
    Ye, Yin
    MICROCHIMICA ACTA, 2014, 181 (11-12) : 1463 - 1470
  • [7] A non-enzymatic hydrogen peroxide sensor based on a glassy carbon electrode modified with cuprous oxide and nitrogen-doped graphene in a nafion matrix
    Bin-Bin Jiang
    Xian-Wen Wei
    Fang-Hui Wu
    Kong-Lin Wu
    Le Chen
    Guo-Zan Yuan
    Chao Dong
    Yin Ye
    Microchimica Acta, 2014, 181 : 1463 - 1470
  • [8] A non-enzymatic urea sensor based on the nickel sulfide/graphene oxide modified glassy carbon electrode
    Naik, T. S. Sunil Kumar
    Saravanan, S.
    Saravana, K. N. Sri
    Pratiush, Utkarsh
    Ramamurthy, Praveen C.
    MATERIALS CHEMISTRY AND PHYSICS, 2020, 245
  • [9] A Novel Non-Enzymatic Glucose Sensor Based on Cobalt Nanoparticles Implantation-Modified Indium Tin Oxide Electrode
    Wang, Tong
    Yu, Yanan
    Tian, Huifeng
    Hu, Jingbo
    ELECTROANALYSIS, 2014, 26 (12) : 2693 - 2700
  • [10] Non-enzymatic amperometric hydrogen peroxide sensor using a glassy carbon electrode modified with gold nanoparticles deposited on CVD-grown graphene
    Yawen Yuan
    Yiqun Zheng
    Jinglei Liu
    Hua Wang
    Shifeng Hou