Diagnostic performance of PET for detection of cardiac amyloidosis: A systematic review and meta-analysis

被引:9
|
作者
Kim, Sang Hyun [1 ]
Kim, Yun Seong [2 ,3 ]
Kim, Seong-Jang [3 ,4 ,5 ]
机构
[1] Dongnam Inst Radiol & Med Sci, Dept Internal Med, Busan, South Korea
[2] Pusan Natl Univ, Dept Internal Med, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, BioMed Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan 50612, South Korea
[4] Pusan Natl Univ, Coll Med, Dept Nucl Med, Yangsan, South Korea
[5] Pusan Natl Univ, Dept Nucl Med, Yangsan Hosp, Yangsan, South Korea
关键词
Amyloid positron emission tomography; F-18 sodium fluoride; Cardiac amyloidosis; MOLECULAR-MECHANISMS; TEST ACCURACY; VISUALIZATION; C-11-PIB; DEPOSITS; BINDING; RATIO; BIAS;
D O I
10.1016/j.jjcc.2020.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of the current investigation was to evaluate the diagnostic accuracy of amyloid and F-18 sodium fluoride (NaF) positron emission tomography/computed tomography (PET/CT) for the detection of cardiac amyloidosis (CA) using diagnostic accuracy test. Materials and methods: The PubMed, Cochrane, and EMBASE database, from the earliest available date of indexing through February 29, 2020, were searched for results investigating the diagnostic accuracy of amyloid and F-18 NaF PET for the diagnosis of CA. We calculated the pooled sensitivities and specificities of included studies, calculated positive and negative likelihood ratios (LR+ and LR-), and obtained summary receiver operating characteristic (SROC) curves. Results: Across 13 studies with 14 results (90 patients), the pooled sensitivity of amyloid PET was 0.97 and a pooled specificity was 0.98. The pooled sensitivity of F-18 NaF PET was 0.63 and a pooled specificity was 1.00. The pooled sensitivity of combined amyloid and F-18 NaF PET was 0.88 and a pooled specificity was 0.98. Conclusion: Amyloid PET has a high sensitivity and specificity for the detection of CA. However, F-18 NaF PET showed relatively low sensitivity with high specificity. At present, the literature regarding the use of amyloid and F-18 NaF PET for diagnosis of CA is still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of amyloid and F-18 NaF PET for detection of CA. (C) 2020 Published by Elsevier Ltd on behalf of Japanese College of Cardiology.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [41] The diagnostic performance of adrenal biopsy: a systematic review and meta-analysis
    Bancos, Irina
    Tamhane, Shrikant
    Shah, Muhammad
    Delivanis, Danae A.
    Alahdab, Fares
    Arlt, Wiebke
    Fassnacht, Martin
    Murad, M. Hassan
    EUROPEAN JOURNAL OF ENDOCRINOLOGY, 2016, 175 (02) : R65 - R80
  • [42] The diagnostic performance of MRI in osteoarthritis: a systematic review and meta-analysis
    Menashe, L.
    Hirko, K.
    Losina, E.
    Kloppenburg, M.
    Zhang, W.
    Li, L.
    Hunter, D. J.
    OSTEOARTHRITIS AND CARTILAGE, 2012, 20 (01) : 13 - 21
  • [43] Value of 18F-FDG PET/MR in the Detection of Pulmonary Malignancies: A Systematic Review and Meta-Analysis on the Diagnostic Performance
    Mirshahvalad, S.
    Hinzpeter, R.
    Kohan, A.
    Anconina, R.
    Kulanthaivelu, R.
    Ortega, C.
    Metser, U.
    Veit-Haibach, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S465 - S465
  • [44] The diagnostic performance of CT versus FDG PET-CT for the detection of recurrent pancreatic cancer: a systematic review and meta-analysis
    Daamen, Lois A.
    Groot, Vincent P.
    Goense, Lucas
    Wessels, Frank J.
    Rinkes, Inne H. Borel
    Intven, Martijn P. W.
    van Santvoort, Hjalmar C.
    Molenaar, I. Quintus
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 106 : 128 - 136
  • [45] Diagnostic performance of PET/CTor PET and CT for detection of peritoneal carcinomatosis: a meta-analysis
    Zhou, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2016, 43 : S361 - S362
  • [46] Characterization of Adrenal Masses by Using FDG PET: A Systematic Review and Meta-Analysis of Diagnostic Test Performance
    Boland, Giles W. L.
    Dwamena, Ben A.
    Sangwaiya, Minal Jagtiani
    Goehler, Alexander G.
    Blake, Michael A.
    Hahn, Peter F.
    Scott, James A.
    Kalra, Mannudeep K.
    RADIOLOGY, 2011, 259 (01) : 117 - 126
  • [47] Diagnostic performance of MRI, SPECT, and PET in detecting renal cell carcinoma: a systematic review and meta-analysis
    Yin, Qihua
    Xu, Huiting
    Zhong, Yanqi
    Ni, Jianming
    Hu, Shudong
    BMC CANCER, 2022, 22 (01)
  • [48] The diagnostic performance of 18fluorine-fluorodeoxyglucose PET for brain metastases: a systematic review and meta-analysis
    Chan, Tak Kwong
    Li, Wai Ip
    Lau, Jeremy Hugh Yen-hey
    Chu, King Sun
    Yong, Ting Kun Au
    Kung, Boom Ting
    NUCLEAR MEDICINE COMMUNICATIONS, 2023, 44 (08) : 741 - 749
  • [49] Diagnostic performance of MRI, SPECT, and PET in detecting renal cell carcinoma: a systematic review and meta-analysis
    Qihua Yin
    Huiting Xu
    Yanqi Zhong
    Jianming Ni
    Shudong Hu
    BMC Cancer, 22
  • [50] Detection of cardiac neuroendocrine tumour metastases by somatostatin receptor PET/CT: a systematic review and meta-analysis
    Campanale, Daniela
    Imperiale, Alessio
    Albano, Domenico
    Rizzo, Alessio
    Piccardo, Arnoldo
    Treglia, Giorgio
    FRONTIERS IN MEDICINE, 2024, 11