Diagnostic performance of PET for detection of cardiac amyloidosis: A systematic review and meta-analysis

被引:9
|
作者
Kim, Sang Hyun [1 ]
Kim, Yun Seong [2 ,3 ]
Kim, Seong-Jang [3 ,4 ,5 ]
机构
[1] Dongnam Inst Radiol & Med Sci, Dept Internal Med, Busan, South Korea
[2] Pusan Natl Univ, Dept Internal Med, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, BioMed Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan 50612, South Korea
[4] Pusan Natl Univ, Coll Med, Dept Nucl Med, Yangsan, South Korea
[5] Pusan Natl Univ, Dept Nucl Med, Yangsan Hosp, Yangsan, South Korea
关键词
Amyloid positron emission tomography; F-18 sodium fluoride; Cardiac amyloidosis; MOLECULAR-MECHANISMS; TEST ACCURACY; VISUALIZATION; C-11-PIB; DEPOSITS; BINDING; RATIO; BIAS;
D O I
10.1016/j.jjcc.2020.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of the current investigation was to evaluate the diagnostic accuracy of amyloid and F-18 sodium fluoride (NaF) positron emission tomography/computed tomography (PET/CT) for the detection of cardiac amyloidosis (CA) using diagnostic accuracy test. Materials and methods: The PubMed, Cochrane, and EMBASE database, from the earliest available date of indexing through February 29, 2020, were searched for results investigating the diagnostic accuracy of amyloid and F-18 NaF PET for the diagnosis of CA. We calculated the pooled sensitivities and specificities of included studies, calculated positive and negative likelihood ratios (LR+ and LR-), and obtained summary receiver operating characteristic (SROC) curves. Results: Across 13 studies with 14 results (90 patients), the pooled sensitivity of amyloid PET was 0.97 and a pooled specificity was 0.98. The pooled sensitivity of F-18 NaF PET was 0.63 and a pooled specificity was 1.00. The pooled sensitivity of combined amyloid and F-18 NaF PET was 0.88 and a pooled specificity was 0.98. Conclusion: Amyloid PET has a high sensitivity and specificity for the detection of CA. However, F-18 NaF PET showed relatively low sensitivity with high specificity. At present, the literature regarding the use of amyloid and F-18 NaF PET for diagnosis of CA is still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of amyloid and F-18 NaF PET for detection of CA. (C) 2020 Published by Elsevier Ltd on behalf of Japanese College of Cardiology.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [21] Update on Diagnostic Performance of PET/MRI in Gynecological Malignancies: A Systematic Review and Meta-Analysis
    Virarkar, Mayur
    Devine, Catherine
    Bassett, Roland, Jr.
    Javadi, Sanaz
    Faria, Silvana De Castro
    Bhosale, Priya
    JOURNAL OF THE BELGIAN SOCIETY OF RADIOLOGY, 2020, 104 (01): : 1 - 10
  • [22] Diagnostic Performance of MRI for the Detection of Pulmonary Nodules: A Systematic Review and Meta-Analysis
    Cavion, Cesar Campagnolo
    Altmayer, Stephan
    Forte, Gabriele Carra
    Andrade, Rubens Gabriel Feijo
    Hochhegger, Daniela Quinto dos Reis
    Francisco, Martina Zaguini
    Camargo Jr, Capitulino
    Patel, Pratik
    Hochhegger, Bruno
    RADIOLOGY-CARDIOTHORACIC IMAGING, 2024, 6 (02):
  • [23] Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis
    Zhao, Lei
    Tian, Zhuang
    Fang, Quan
    BMC CARDIOVASCULAR DISORDERS, 2016, 16
  • [24] Diagnostic Accuracy and Prognostic Value of Relative Apical Sparing in Cardiac Amyloidosis - Systematic Review and Meta-Analysis -
    Lee, Chung-Yen
    Nabeshima, Yosuke
    Kitano, Tetsuji
    Yang, Li-Tan
    Takeuchi, Masaaki
    CIRCULATION JOURNAL, 2025, 89 (01) : 16 - 23
  • [25] Diagnostic accuracy of cardiovascular magnetic resonance for patients with suspected cardiac amyloidosis: a systematic review and meta-analysis
    Lei Zhao
    Zhuang Tian
    Quan Fang
    BMC Cardiovascular Disorders, 16
  • [26] Performance of bone tracer for diagnosis and differentiation of transthyretin cardiac amyloidosis: a systematic review and meta-analysis
    Zhao, Hongliang
    Hu, Haijuan
    Cui, Wei
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2021, 27 (06): : 802 - 810
  • [27] The diagnostic performance of the ductus venosus for the detection of cardiac defects in the first trimester: a systematic review and diagnostic test accuracy meta-analysis
    Savoia, Fabiana
    Scala, Carolina
    Coppola, Marlene
    Riemma, Gaetano
    Vitale, Salvatore Giovanni
    Mikus, Mislav
    Schiattarella, Antonio
    La Verde, Marco
    Colacurci, Nicola
    De Franciscis, Pasquale
    Morlando, Maddalena
    ARCHIVES OF GYNECOLOGY AND OBSTETRICS, 2023, 308 (02) : 435 - 451
  • [28] The diagnostic performance of the ductus venosus for the detection of cardiac defects in the first trimester: a systematic review and diagnostic test accuracy meta-analysis
    Fabiana Savoia
    Carolina Scala
    Marlene Coppola
    Gaetano Riemma
    Salvatore Giovanni Vitale
    Mislav Mikuš
    Antonio Schiattarella
    Marco La Verde
    Nicola Colacurci
    Pasquale De Franciscis
    Maddalena Morlando
    Archives of Gynecology and Obstetrics, 2023, 308 : 435 - 451
  • [29] Diagnostic performance of F-18 FDG PET or PET/CT for detection of recurrent gastric cancer: a systematic review and meta-analysis
    Choi, Chang In
    Park, Jae Kyun
    Jeon, Tae Yong
    Kim, Dae-Hwan
    JOURNAL OF YEUNGNAM MEDICAL SCIENCE, 2023, 40 : S37 - S46
  • [30] The diagnostic performance of [18F]FDG PET/CT in the detection of melanoma recurrence: a systematic review and meta-analysis
    Zhu, Tingting
    Liao, Maoxin
    Huang, Maoxin
    Xiao, Fengli
    CLINICAL AND TRANSLATIONAL IMAGING, 2024, 12 (05) : 501 - 512