Diagnostic performance of PET for detection of cardiac amyloidosis: A systematic review and meta-analysis

被引:9
|
作者
Kim, Sang Hyun [1 ]
Kim, Yun Seong [2 ,3 ]
Kim, Seong-Jang [3 ,4 ,5 ]
机构
[1] Dongnam Inst Radiol & Med Sci, Dept Internal Med, Busan, South Korea
[2] Pusan Natl Univ, Dept Internal Med, Yangsan Hosp, Yangsan, South Korea
[3] Pusan Natl Univ, BioMed Res Inst Convergence Biomed Sci & Technol, Yangsan Hosp, Yangsan 50612, South Korea
[4] Pusan Natl Univ, Coll Med, Dept Nucl Med, Yangsan, South Korea
[5] Pusan Natl Univ, Dept Nucl Med, Yangsan Hosp, Yangsan, South Korea
关键词
Amyloid positron emission tomography; F-18 sodium fluoride; Cardiac amyloidosis; MOLECULAR-MECHANISMS; TEST ACCURACY; VISUALIZATION; C-11-PIB; DEPOSITS; BINDING; RATIO; BIAS;
D O I
10.1016/j.jjcc.2020.07.003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The purpose of the current investigation was to evaluate the diagnostic accuracy of amyloid and F-18 sodium fluoride (NaF) positron emission tomography/computed tomography (PET/CT) for the detection of cardiac amyloidosis (CA) using diagnostic accuracy test. Materials and methods: The PubMed, Cochrane, and EMBASE database, from the earliest available date of indexing through February 29, 2020, were searched for results investigating the diagnostic accuracy of amyloid and F-18 NaF PET for the diagnosis of CA. We calculated the pooled sensitivities and specificities of included studies, calculated positive and negative likelihood ratios (LR+ and LR-), and obtained summary receiver operating characteristic (SROC) curves. Results: Across 13 studies with 14 results (90 patients), the pooled sensitivity of amyloid PET was 0.97 and a pooled specificity was 0.98. The pooled sensitivity of F-18 NaF PET was 0.63 and a pooled specificity was 1.00. The pooled sensitivity of combined amyloid and F-18 NaF PET was 0.88 and a pooled specificity was 0.98. Conclusion: Amyloid PET has a high sensitivity and specificity for the detection of CA. However, F-18 NaF PET showed relatively low sensitivity with high specificity. At present, the literature regarding the use of amyloid and F-18 NaF PET for diagnosis of CA is still limited; thus, further large multicenter studies would be necessary to substantiate the diagnostic accuracy of amyloid and F-18 NaF PET for detection of CA. (C) 2020 Published by Elsevier Ltd on behalf of Japanese College of Cardiology.
引用
收藏
页码:618 / 625
页数:8
相关论文
共 50 条
  • [1] Diagnostic performance of CMR, SPECT, and PET imaging for the detection of cardiac amyloidosis: a meta-analysis
    Wu, Zhaoye
    Yu, Chunjing
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [2] Diagnostic performance of CMR, SPECT, and PET imaging for the detection of cardiac amyloidosis: a meta-analysis
    Zhaoye Wu
    Chunjing Yu
    BMC Cardiovascular Disorders, 21
  • [3] Diagnostic performance of imaging investigations in detecting and differentiating cardiac amyloidosis: a systematic review and meta-analysis
    Brownrigg, Jack
    Lorenzini, Massimiliano
    Lumley, Matthew
    Elliott, Perry
    ESC HEART FAILURE, 2019, 6 (05): : 1041 - 1051
  • [4] Diagnostic performance of F-18 FDG PET for detection of cardiac sarcoidosis; A systematic review and meta-analysis
    Seong-Jang Kim
    Kyoungjune Pak
    Keunyoung Kim
    Journal of Nuclear Cardiology, 2020, 27 : 2103 - 2115
  • [5] Diagnostic performance of F-18 FDG PET for detection of cardiac sarcoidosis; A systematic review and meta-analysis
    Kim, Seong-Jang
    Pak, Kyoungjune
    Kim, Keunyoung
    JOURNAL OF NUCLEAR CARDIOLOGY, 2020, 27 (06) : 2103 - 2115
  • [6] Diagnostic performance of advanced cardiac imaging for detection of cardiac sarcoidosis: a systematic review and meta-analysis
    Ballo, H.
    Saraste, A.
    Doghman, F.
    Knuuti, J.
    EUROPEAN HEART JOURNAL, 2020, 41 : 325 - 325
  • [7] AI FOR THE DETECTION OF CARDIAC AMYLOIDOSIS: INSIGHTS FROM A SYSTEMATIC REVIEW AND META-ANALYSIS
    Adams, Cobi
    Gorrie, Natasha
    Raftopulos, Nikki
    Olsen, Nick
    Bart, Nicole
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 400 - 400
  • [8] Diagnostic Test Accuracy of Cardiac Imaging for AL Amyloidosis: A Systematic Review and Meta-Analysis
    Kawtharany, Hassan
    Azzam, Muayad
    Nazzal, Jamil
    Kukreti, Vishal
    Seftel, Matthew D.
    Hamarsha, Qais
    Alkhader, Aseel
    Khraise, Tala
    Almasri, Mohammad Mahmoud
    Zeid, Hadi Khaled Abou
    Alwan, Iktimal
    Alzabibi, Mhd Amin
    Jaber, Noor
    Darwish, Laura
    Jamal, Faizi
    Dasgupta, Noel
    Sarswat, Nitasha
    de la Torre, Alfredo H.
    Aguirre, Maria Adela
    Boedicker, Deborah
    Bumma, Naresh
    Carroll, Antonia
    Comenzo, Raymond
    Cook, Joselle
    Dispenzieri, Angela
    Khouri, Jack
    Picken, Maria M.
    Raza, Shahzad
    Leung, Nelson
    Sanchorawala, Vaishali
    Shaikh, Hira
    Singh, Daulath
    Mustafa, Reem A.
    BLOOD, 2024, 144 : 1919 - 1920
  • [9] Diagnostic Performance of Echocardiography for the Detection of Acute Cardiac Allograft Rejection: A Systematic Review and Meta-Analysis
    Lu, Wei
    Zheng, Jun
    Pan, Xudong
    Sun, Lizhong
    PLOS ONE, 2015, 10 (03):
  • [10] Diagnostic performance of choline PET for detection of hyperfunctioning parathyroid glands in hyperparathyroidism: a systematic review and meta-analysis
    Treglia, Giorgio
    Piccardo, Arnoldo
    Imperiale, Alessio
    Strobel, Klaus
    Kaufmann, Philipp A.
    Prior, John O.
    Giovanella, Luca
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (03) : 751 - 765