MEASUREMENT OF PERSONAL DOSE EQUIVALENT OF X AND GAMMA RADIATION BY RING DOSIMETER: RESULTS OF INTERCOMPARISON MEASUREMENTS

被引:0
|
作者
Adamowicz, Malgorzata [1 ]
Papierz, Sylwia [1 ]
Kacprzyk, Janusz [1 ]
Kaminski, Zbigniew [1 ]
Zmyslony, Marek [1 ]
机构
[1] Nofer Inst Occupat Med, Dept Radiat Protect, PL-91348 Lodz, Poland
关键词
interlaboratory comparisons; X-ray and gamma radiation; personal dose equivalent; ring dosimeter; thermoluminescence detectors;
D O I
暂无
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: The aim of the study was to present the results of the interlaboratory comparisons for ring dosimeters and to confirm that the applied method is suitable for measuring the personal dose equivalent H-p(0.07). In addition, calibration procedures used in dosimetric measurements in persons occupationally exposed to ionizing photon radiation X and gamma were presented. Materials and Methods: Ring dosimeters made of flexible plastics with the diameter of approximately 20 mm, equipped with two thermoluminescence (TL) detectors type MTS-N, were the subject of interlaboratory comparisons. Irradiated detectors were red out using a new manual TLD's reader (FIMEL, France). All TLD exposures were done for validation of TLD readers and were performed using the reference X-ray and gamma beams with the ISO rod phantom. The methodology of performed exposures corresponded with the methods applied by the European Radiation Dosimetry Group (EURADOS), the European organizer ofinterlaboratory comparisons. RESULTS: The energy, dose and angular characteristics of the ring dosimeter allowed to elaborate the formula for estimating and verifying the personal dose equivalent H-p(0.07). The test was performed to check and confirm the correctness of the estimated characteristics. The test results were satisfactory, and thus the readiness to implement TLD reader in the used method and to participate in interlaboratory comparisons was confirmed. Conclusions: According to the requirements of the Polish Centre for Accreditation, the laboratory was participating in the interlaboratory comparison organized by EURADOS in terms of the personal dose equivalent H-p(0.07). The result of the comparison was satisfactory, therefore the correctness of the testing procedure was confirmed.
引用
收藏
页码:631 / 637
页数:7
相关论文
共 50 条
  • [21] MEASUREMENT OF BETA-ABSORBED DOSE USING TLD PERSONAL DOSIMETER
    MIYABE, K
    NOMURA, Y
    ISHIGURO, H
    HEALTH PHYSICS, 1984, 46 (06): : 1327 - 1327
  • [22] DIAMOND DOSIMETER FOR X-RAY AND GAMMA-RADIATION
    KOZLOV, SF
    KONOROVA, EA
    KUZNETSOV, YA
    SALIKOV, YA
    REDKO, VI
    GRINBERG, VR
    MEILMAN, ML
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) : 235 - 237
  • [23] SELF-POWERED DOSIMETER FOR GAMMA + X-RADIATION
    HOSEMANN, R
    WARRIKHOFF, FH
    NUCLEONICS, 1964, 22 (03): : 51 - +
  • [24] MCz diode response as a high-dose gamma radiation dosimeter
    Camargo, F.
    Goncalves, J. A. C.
    Khoury, H. J.
    Napolitano, C. M.
    Harkonen, J.
    Bueno, C. C.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 1160 - 1162
  • [25] Gamma-Ray Dose Measurement with Radio-Photoluminescence Glass Dosimeter in Mixed Radiation Field for BNCT
    Hiramatsu, K.
    Yoshihashi, S.
    Kusaka, S.
    Sato, F.
    Hoashi, E.
    Murata, I.
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [26] CALIBRATION AND MEASUREMENT OF THE X-RAY PERSONAL DOSE EQUIVALENT WITH A Hp(10) IONIZATION CHAMBER
    Xu, Yang
    Zhao, Rui
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2021, 36 (02): : 174 - 181
  • [27] A CYTOGENETIC MODEL AS DOSIMETER FOR ABSORBED DOSE FOLLOWING X-RAY OR GAMMA-RAY RADIATION ACCIDENTS
    MINNAAR, PC
    JANSEN, S
    MEDICAL PHYSICS, 1987, 14 (04) : 712 - 712
  • [28] Programmable zone dosimeter for operational monitoring and measurement of external gamma radiation
    Toledo, R
    Osorio, JF
    López, E
    Pablo, L
    MEDICAL PHYSICS, 2002, 630 : 247 - 250
  • [29] Dose of radiation enhancement, using silver nanoparticles in a human tissue equivalent gel dosimeter
    Hassan, Muhammad
    Rehman, Ateeque Ur
    Waheed, Muhammad Mohsin
    Anjum, Muhammad Naeem
    JOURNAL OF THE PAKISTAN MEDICAL ASSOCIATION, 2016, 66 (01) : 45 - 48
  • [30] APPLICATION OF THE PIN DIODE AS A DOSIMETER FOR DOSE MEASUREMENT OF SEVERAL RADIATION SOURCES
    Sopko, Vit
    Dammer, Jiri
    Chren, Dominik
    Sopko, Bruno
    Latal, Frantisek
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 140 - 144