Gamma-Ray Dose Measurement with Radio-Photoluminescence Glass Dosimeter in Mixed Radiation Field for BNCT

被引:3
|
作者
Hiramatsu, K. [1 ]
Yoshihashi, S. [2 ]
Kusaka, S. [1 ]
Sato, F. [1 ]
Hoashi, E. [1 ]
Murata, I. [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Yamada Oka 2-1, Suita, Osaka 5650871, Japan
[2] Fukui Univ Technol, Dept Appl Nucl Technol, Gakuen 3-6-1, Fukui, Fukui 9108505, Japan
关键词
D O I
10.1051/epjconf/201715304009
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Accelerator based neutron sources (ABNS) are being developed as the next generation neutron irradiation system for BNCT. From the ABNS, unnecessary gamma-rays will be generated by neutron capture reactions, as well as fast neutrons. To control the whole-body radiation dose to the patient, measurement of gamma-ray dose in the irradiation room is necessary. In this study, the objective is to establish a method to measure gamma-ray dose separately in a neutron/gamma mixed field by using RPL glass dosimeter. For this purpose, we proposed a lead filter method which uses a pair of RPL glasses with and without a lead filter outside. In order to realize this method, the basic characteristics of glass dosimeter was verified in the gamma-ray field, before adapting it in the mixture field. From the result of the experiment using the lead filter, the simulation result especially for the case with a lead filter overestimated the absorbed does obtained from measurement. We concluded that the reason of the discrepancy is caused by existence of gradient of the dose distribution in the glass, and the difference of sensitivity to low-energy photon between measurement and theory.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Preparation and property of radio-photoluminescence dosimeter glass
    Fan, Si-Jun
    Yu, Chun-Lei
    He, Dong-Bing
    Hu, Li-Li
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2013, 47 (03): : 502 - 507
  • [2] Accurate gamma-ray dose measurement up to 10 MeV by glass dosimeter with a sensitivity control filter for BNCT
    Kamisaki, F.
    Inoue, T.
    Tomiyoshi, K.
    Matsuki, M.
    Aoki, K.
    Kusaka, S.
    Tamaki, S.
    Sato, F.
    Murata, I.
    APPLIED RADIATION AND ISOTOPES, 2024, 209
  • [3] Gamma rays induced defect centers in phosphate glass for radio-photoluminescence dosimeter
    Fan, Sijun
    Yu, Chunlei
    He, Dongbing
    Li, Kefeng
    Hu, Lili
    RADIATION MEASUREMENTS, 2011, 46 (01) : 46 - 50
  • [4] POLARIZATION OF RADIO-PHOTOLUMINESCENCE OF FLUORO-DOSIMETER GLASS
    KISHII, T
    SAKURAI, J
    JOURNAL OF THE PHYSICAL SOCIETY OF JAPAN, 1965, 20 (07) : 1271 - &
  • [5] LITHIUM-7 DOSIMETER GLASS FOR SIMULTANEOUS MEASUREMENT OF THERMAL NEUTRON AND COEXISTING GAMMA-RAY DOSE
    YOKOTA, R
    NAKAJIMA, S
    BINGO, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1969, 6 (04): : 224 - +
  • [6] A ratiometric radio-photoluminescence dosimeter based on a radical excimer for X-ray detection
    Lu, Huangjie
    Ma, Jingqi
    Yang, Junpu
    Hou, Huiliang
    Lu, Jiacheng
    Wang, Jian-Qiang
    Wang, Yaxing
    Lin, Jian
    CHEMICAL COMMUNICATIONS, 2023, 59 (84) : 12617 - 12620
  • [7] Development of a gamma-ray detector for dose monitoring in BNCT
    Caracciolo, A.
    Di Vita, D.
    Ferri, T.
    Carminati, M.
    Protti, N.
    Altieri, S.
    Camera, F.
    Fiorini, C.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S638 - S639
  • [8] Response control of RPLGD for gamma-ray dose measurement using lead filters for BNCT
    Tochitani, K.
    Tomiyoshi, K.
    Inoue, T.
    Kamisaki, F.
    Matsuki, M.
    Hiramatsu, K.
    Aoki, K.
    Kusaka, S.
    Tamaki, S.
    Sato, F.
    Murata, I.
    APPLIED RADIATION AND ISOTOPES, 2023, 199
  • [9] Impact of testicular shielding in liposarcoma to scrotum by using radio-photoluminescence glass dosimeter (RPLGD): a case report
    Oonsiri, Puntiwa
    Saksornchai, Kitwadee
    Suriyapee, Sivalee
    RADIATION ONCOLOGY JOURNAL, 2018, 36 (03): : 248 - 253
  • [10] A CYTOGENETIC MODEL AS DOSIMETER FOR ABSORBED DOSE FOLLOWING X-RAY OR GAMMA-RAY RADIATION ACCIDENTS
    MINNAAR, PC
    JANSEN, S