Dehumidification performance of a variable speed heat pump and a single speed heat pump with and without dehumidification capabilities in a warm and humid climate

被引:9
|
作者
Kone, Koukouni P. [1 ]
Fumo, Nelson [1 ]
机构
[1] Univ Texas Tyler, Mech Engn Dept, Tyler, TX 75799 USA
关键词
Air humidity control; Residential air conditioning; Air dehumidification; Thermal comfort;
D O I
10.1016/j.egyr.2020.06.024
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Conventional air conditioning systems in houses respond to thermal loads by means of controlling dry-bulb temperature through the thermostat. As part of the process to control temperature, dehumidification is also provided. However, as houses are becoming more efficient, supplemental dehumidification is often necessary for homes located in hot and humid climates to control relative humidity intentionally. This study compared the dehumidification performance of a residential air conditioning system working in three operations modes to emulate three different systems: a system with a variable speed mode, a single-speed system with an enhanced dehumidification mode, and a single-speed system operating in a traditional or normal cooling mode. With operation mode changes achieved through software, this study constituted a novelty in the topic of humidity control by using a single machine, with the same exact physical set-up to directly compare the dehumidification performance of three types of systems. Two types of days were of interest in the study, hot and humid days (summer season) and mild and humid days (Fall shoulder season). After assessment of the dehumidification performance, the variable speed mode was able to maintain relative humidity between 50% to 52% on summer days. In the single-speed with enhanced dehumidification, a slightly less effective humidity control was achieved on summer days with the mode keeping the relative humidity between 53% to 55%. In the normal cooling mode, which resembles a conventional system, the humidity levels were controlled between 55% to 60%. In the shoulder season, the variable speed and enhanced dehumidification modes maintained the relative humidity between 55% to 58% and 53% to 56% respectively. In the shoulder season, the normal cooling mode kept the indoor relative humidity near or above 60%. In terms of dehumidification efficiency expressed as a function of the amount of water condensate per unit of energy, the variable speed was determined to be more efficient than the other modes. (C) 2020 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:1696 / 1701
页数:6
相关论文
共 50 条
  • [31] Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Xie, Ying
    Zhang, Tao
    Liu, Xiaohua
    ENERGY, 2016, 115 : 446 - 457
  • [32] Experimental investigation of heat recovery in a humidification-dehumidification desalination system via a heat pump
    Shafii, Mohammad Behshad
    Jafargholi, Hamed
    Faegh, Meysam
    DESALINATION, 2018, 437 : 81 - 88
  • [33] Water productivity enhancement in variable pressure humidification dehumidification (HDH) desalination systems using heat pump
    Ayati, Emad
    Rahimi-Ahar, Zohreh
    Hatamipour, Mohammad Sadegh
    Ghalavand, Younes
    APPLIED THERMAL ENGINEERING, 2019, 160
  • [34] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204
  • [35] Experimental study on a fresh air heat pump desiccant dehumidification system using rejected heat
    Chai, Shaowei
    Zhao, Yao
    Ge, Tianshu
    Dai, Yanjun
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [36] AN ECONOMIC COMPARISON OF A FIXED SPEED, A 2 SPEED, AND A VARIABLE SPEED VAPOR COMPRESSION HEAT-PUMP
    MARQUAND, CJ
    TASSOU, SA
    WANG, YT
    WILSON, DR
    APPLIED ENERGY, 1984, 16 (01) : 59 - 66
  • [37] Humidification-dehumidification and heat pump integration for water purifier and air conditioning
    Tangellapalli, Srinivas
    ENERGY CONVERSION AND MANAGEMENT, 2021, 244
  • [38] Effects of the frequency conversion characteristics of fan and pump on the performance of heat pump driven humidification-dehumidification wastewater treatment system
    Zhang, Huichen
    Liu, Jianhua
    Jiang, Linlin
    Zhang, Liang
    Wu, Qingqing
    Xu, Xiaojin
    HEAT AND MASS TRANSFER, 2022, 58 (12) : 2067 - 2083
  • [39] Effects of the frequency conversion characteristics of fan and pump on the performance of heat pump driven humidification-dehumidification wastewater treatment system
    Huichen Zhang
    Jianhua Liu
    Linlin Jiang
    Liang Zhang
    Qingqing Wu
    Xiaojin Xu
    Heat and Mass Transfer, 2022, 58 : 2067 - 2083
  • [40] Experimental study of a humidification-dehumidification desalination system with heat pump unit
    Zhang, Yin
    Zhu, Chunguang
    Zhang, Huan
    Zheng, Wandong
    You, Shijun
    Zhen, Yuhan
    DESALINATION, 2018, 442 : 108 - 117