Comparison of versions 1.0 and 1.5 of the UltraSensitive AMPLICOR HIV-1 MONITOR test for subjects with low viral load

被引:7
|
作者
Jackson, JB
Piwowar-Manning, E
Johnson-Lewis, L
Bassett, R
Demeter, LM
Brambilla, D
机构
[1] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD 21287 USA
[2] Harvard Univ, Sch Publ Hlth, SDAC, Boston, MA 02115 USA
[3] Univ Rochester, Med Ctr, Rochester, NY 14642 USA
[4] New England Res Inst, Watertown, MA 02472 USA
关键词
D O I
10.1128/JCM.42.6.2774-2776.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We compared the performance of two UltraSensitive AMPLICOR HIV-1 MONITOR kits (version 1.5 [v1.5] versus v1.0) by retesting 404 plasma samples with low viral loads (<3,000 copies/ml) with both kits. With 292 samples that initially had <50 copies/ml by the v1.0 kit, the v1.5 assay was more sensitive than the v1.0 assay for samples with human immunodeficiency virus type 1 RNA near the 50-copy/ml cutoff (P = 0.0146). Median numbers of copies per milliliter were similar for 112 samples with 50 to 3,000 copies/ml with no difference in sensitivity with a 200-copy/ml cutoff.
引用
收藏
页码:2774 / 2776
页数:3
相关论文
共 50 条
  • [41] Development of calibrated viral load standards for group M subtypes of human immunodeficiency virus type 1 and performance of an improved AMPLICOR HIV-1 MONITOR test with isolates of diverse subtypes
    Michael, NL
    Herman, SA
    Kwok, S
    Dreyer, K
    Wang, J
    Christopherson, C
    Spadoro, JP
    Young, KKY
    Polonis, V
    McCutchan, FE
    Carr, J
    Mascola, JR
    Jagodzinsi, LL
    Robb, ML
    JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (08) : 2557 - 2563
  • [42] Evaluation of the ultrasensitive Roche Amplicor HIV-1 monitor assay for quantitation of human immunodeficiency virus type I RNA
    Erali, M
    Hillyard, DR
    JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (03) : 792 - 795
  • [43] Comparative evaluation of the Abbott HIV-1 RealTime™ assay with the Standard Roche COBAS® Amplicor™ HIV-1 Monitor® Test, v1.5 for determining HIV-1 RNA levels in plasma specimens from Pune, India
    Khopkar, Priyanka
    Mallav, Vikas
    Chidrawar, Shweta
    Kulkarni, Smita
    JOURNAL OF VIROLOGICAL METHODS, 2013, 191 (01) : 82 - 87
  • [44] Comparative performance of three viral load assays on human immunodeficiency virus type 1 (HIV-1) isolates representing group M (subtypes A to G) and group O: LCx HIV RNA Quantitative, AMPLICOR HIV-1 MONITOR version 1.5, and Quantiplex HIV-1 RNA version 3.0
    Swanson, P
    Soriano, V
    Devare, SG
    Hackett, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2001, 39 (03) : 862 - 870
  • [45] Plasma load discrepancies between the Roche Cobas Amplicor human immunodeficiency virus type 1 (HIV-1) monitor version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 assays - Reply
    Damond, F.
    Roquebert, B.
    Descamps, D.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2008, 46 (02) : 834 - 834
  • [46] Entirely automated quantification of human immunodeficiency virus type 1 (HIV-1) RNA in plasma by using the ultrasensitive COBAS AMPLICOR HIV-1 monitor test and RNA purification on the MagNA pure LC instrument
    Hölzl, G
    Stöcher, M
    Leb, V
    Stekel, H
    Berg, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 2003, 41 (03) : 1248 - 1251
  • [47] Comparison of the Abbott m2000 HIV-1 Real-Time and Roche AMPLICOR Monitor v1.5 HIV-1 assays on plasma specimens from Rakai, Uganda
    Ssebugenyi, I.
    Kizza, A.
    Mpoza, B.
    Aluma, G.
    Boaz, I.
    Newell, K.
    Laeyendecker, O.
    Shott, J. P.
    Serwadda, D.
    Reynolds, S. J.
    INTERNATIONAL JOURNAL OF STD & AIDS, 2011, 22 (07) : 373 - 375
  • [48] Longitudinal comparison of HIV-1 plasma viral load and cellular proviral load
    Schweitzer, Finja
    Mikkola, Visa
    Timmen-Wego, Monika
    Jensen, Bjoern
    Faetkenheuer, Gerd
    Kaiser, Rolf
    JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2014, 17 : 117 - 118
  • [49] Comparative evaluation of the QUANTIPLEX HIV-1 RNA 2.0 and 3.0 (bDNA) assays and the AMPLICOR HIV-1 MONITOR v1.5 test for the quantitation of human immunodeficiency virus type 1 RNA in plasma
    Anastassopoulou, CG
    Toulomi, G
    Katsoulidou, A
    Hatzitheodorou, H
    Pappa, M
    Paraskevis, D
    Lazanas, M
    Gargalianos, P
    Hatzakis, A
    JOURNAL OF VIROLOGICAL METHODS, 2001, 91 (01) : 67 - 74
  • [50] NucliSensHIV-1 QT和Amplicor HIV-1 monitor 1.5方法测定HIV-1病毒载量的比较研究
    潘品良
    许文燕
    姚均
    陶晓霞
    裴丽健
    蒋岩
    中华实验和临床病毒学杂志, 2007, (02)