Comparison of versions 1.0 and 1.5 of the UltraSensitive AMPLICOR HIV-1 MONITOR test for subjects with low viral load

被引:7
|
作者
Jackson, JB
Piwowar-Manning, E
Johnson-Lewis, L
Bassett, R
Demeter, LM
Brambilla, D
机构
[1] Johns Hopkins Med Inst, Dept Pathol, Baltimore, MD 21287 USA
[2] Harvard Univ, Sch Publ Hlth, SDAC, Boston, MA 02115 USA
[3] Univ Rochester, Med Ctr, Rochester, NY 14642 USA
[4] New England Res Inst, Watertown, MA 02472 USA
关键词
D O I
10.1128/JCM.42.6.2774-2776.2004
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
We compared the performance of two UltraSensitive AMPLICOR HIV-1 MONITOR kits (version 1.5 [v1.5] versus v1.0) by retesting 404 plasma samples with low viral loads (<3,000 copies/ml) with both kits. With 292 samples that initially had <50 copies/ml by the v1.0 kit, the v1.5 assay was more sensitive than the v1.0 assay for samples with human immunodeficiency virus type 1 RNA near the 50-copy/ml cutoff (P = 0.0146). Median numbers of copies per milliliter were similar for 112 samples with 50 to 3,000 copies/ml with no difference in sensitivity with a 200-copy/ml cutoff.
引用
收藏
页码:2774 / 2776
页数:3
相关论文
共 50 条
  • [21] Performance of the Abbott RealTime HIV-1 assay versus the Roche Amplicor HIV-1 MonitorTM Test, v1.5, UltraSensitive assay for samples with low plasma HIV-1 RNA copy numbers
    Stephan, Christoph
    Hill, Andrew
    Hadacek, Maria Blanca
    van Delft, Yvonne
    Moecklinghoff, Christiane
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2014, 69 (06) : 1708 - 1710
  • [22] Failure to detect a non-B HIV-1 subtype by the HIV-1 Amplicor Monitor test, version 1.5: a case of unexpected vertical transmission
    Geelen, S
    Lange, J
    Borleffs, A
    Wolfs, T
    Weersink, A
    Schuurman, R
    AIDS, 2003, 17 (05) : 781 - 782
  • [23] Xpert HIV-1 Viral Load Assay and VERSANT HIV-1 RNA 1.5 Assay: A Performance Comparison
    Bruzzone, Bianca
    Caligiuri, Patrizia
    Nigro, Nicola
    Arcuri, Claudia
    Delucis, Sabrina
    Di Biagio, Antonio
    Icardi, Giancarlo
    JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2017, 74 (03) : E86 - E88
  • [24] Performance of the Automated COBAS AmpliPrep/COBAS TaqMan HIV-1 Test on a Genetically Diverse Panel of Specimens from China: Comparison to the COBAS Amplicor HIV-1 Monitor Test, v1.5
    Xu, Sihong
    Song, Aijing
    Li, Xiuhua
    Nie, Jianhui
    Zhang, Chuntao
    Wang, Youchun
    INTERVIROLOGY, 2010, 53 (04) : 221 - 228
  • [25] The ultrasensitive NASBA assay for quantifying HIV-1 viral load
    Mas, A
    Soriano, V
    Gomez-Cano, I
    Rodriguez-Rosado, R
    Perez-Olmeda, M
    Gonzalez-Lahoz, J
    ANTIVIRAL THERAPY, 1998, 3 (01) : 43 - 44
  • [26] Amplicor HIV monitor, NASBA HIV-1 RNA QT and quantiplex HIV RNA version 2.0 viral load assays: a Canadian evaluation
    Prud'homme, IT
    Kim, JE
    Pilon, RG
    Minkus, T
    Hawley-Foss, N
    Cameron, W
    Rud, EW
    JOURNAL OF CLINICAL VIROLOGY, 1998, 11 (03) : 189 - 202
  • [27] HIV-1 genotypic resistance test in specimens with a low viral load
    Yang, Z.
    Habibi, A.
    Seyedjafari, R.
    Dong, J.
    CLINICAL CHEMISTRY, 2008, 54 (06) : A161 - A161
  • [28] Evaluation of a next-generation Vacutainer® tube for HIV viral load measurements with the Roche COBAS Amplicor HIV-1 Monitor® Assay
    Rainen, L.
    Belem, P.
    Wan, H.
    Dastane, A.
    Brown, M.
    Fernandes, H.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2006, 8 (05): : 645 - 645
  • [29] Comparison of the Generic HIV Viral Load® assay with the Amplicor™ HIV-1 Monitor v1.5 and Nuclisens HIV-1 EasyQ® v1.2 techniques for plasma HIV-1 RNA quantitation of non-B subtypes: The Kesho Bora preparatory study
    Rouet, Francois
    Foulongne, Vincent
    Viljoen, Johannes
    Steegen, Kim
    Becquart, Pierre
    Valea, Diane
    Danaviah, Sivapragashini
    Segondy, Michel
    Verhofstede, Chris
    Van de Perre, Philippe
    JOURNAL OF VIROLOGICAL METHODS, 2010, 163 (02) : 253 - 257
  • [30] Assay of plasma samples representing different HIV-1 genetic subtypes: An evaluation of new versions of the Amplicor HIV-1 monitor assay
    Alaeus, A
    Lilja, E
    Herman, S
    Spadoro, J
    Wang, J
    Albert, J
    AIDS RESEARCH AND HUMAN RETROVIRUSES, 1999, 15 (10) : 889 - 894