Background: Various fabrication methods are used to improve the stability and osseointegration of screws within the host bone. The aim of this study was to investigate whether roughened surface titanium screws fabricated by electron beam melting can provide better stability and osseointegration as compared with smooth titanium screws in sheep cervical vertebrae. Methods: Roughened surface titanium screws, fabricated by electron beam melting, and conventional smooth surface titanium screws were implanted into sheep for 6 or 12 weeks (groups A and B, respectively). Bone ingrowth and implant stability were assessed with three-dimensional imaging and reconstruction, as well as histological and biomechanical tests. Results: No screws in either group showed signs of loosening. Fibrous tissue formation could be seen around the screws at 6 weeks, which was replaced with bone at 12 weeks. Bone volume/total volume, bone surface area/bone volume, and the trabecular number were significantly higher for a define region of interest surrounding the roughened screws than that surrounding the smooth screws at 12 weeks. Indeed, for roughened screws, trabecular number was significantly higher at 12 weeks than at 6 weeks. On mechanical testing, the maximum pullout strength was significantly higher at 12 weeks than at 6 weeks, as expected; however, no significant differences were found between smooth and roughened screws at either time point. The maximum torque to extract the roughened screws was higher than that required for the smooth screws. Conclusions: Electron beam melting is a simple and effective method for producing a roughened surface on titanium screws. After 12 weeks, roughened titanium screws demonstrated a high degree of osseointegration and increased torsional resistance to extraction over smooth titanium screws.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The electron beam melting and refining of titanium alloys
    Mitchell, A
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1999, 263 (02): : 217 - 223
  • [22] Development of the electron beam melting technology of titanium
    Paton, B.E.
    Trigub, N.P.
    Akhonin, S.V.
    Zamkov, V.N.
    Ivasishin, O.M.
    Problemy Spetsial'noj Electrometallugii, 2000, (02): : 34 - 40
  • [23] ELECTRON-BEAM MELTING OF SPONGE TITANIUM
    KANAYAMA, H
    KUSAMICHI, T
    MURAOKA, T
    ONOYE, T
    NISHIMURA, T
    TETSU TO HAGANE-JOURNAL OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1991, 77 (04): : 512 - 519
  • [24] ELECTRON-BEAM MELTING OF SPONGE TITANIUM
    KANAYAMA, H
    KUSAMICHI, T
    MURAOKA, T
    ONOUYE, T
    NISHIMURA, T
    ISIJ INTERNATIONAL, 1991, 31 (08) : 906 - 914
  • [25] SELECTIVE ELECTRON BEAM MELTING OF TITANIUM AND TITANIUM ALUMINIDE ALLOYS
    Tang, Huiping
    Lu, Shenglu
    Jia, Wenpeng
    Yang, Guangyu
    Qian, Ma
    INTERNATIONAL JOURNAL OF POWDER METALLURGY, 2014, 50 (01): : 57 - 64
  • [26] Microstructures of Niobium Components Fabricated by Electron Beam Melting
    Martinez E.
    Murr L.E.
    Hernandez J.
    Pan X.
    Amato K.
    Frigola P.
    Terrazas C.
    Gaytan S.
    Rodriguez E.
    Medina F.
    Wicker R.B.
    Martinez, E. (emartinez21@miners.utep.edu), 1600, Springer Science and Business Media, LLC (02): : 183 - 189
  • [27] Hydrothermal Modification of Products Fabricated by Electron Beam Melting
    Fukuda, Hidetsugu
    Ueda, Masato
    Ikeda, Masahiko
    Nakano, Takayoshi
    BIOCERAMICS 24, 2013, 529-530 : 580 - +
  • [28] Compressive and fatigue behavior of beta-type titanium porous structures fabricated by electron beam melting
    Liu, Y. J.
    Wang, H. L.
    Li, S. J.
    Wang, S. G.
    Wang, W. J.
    Hou, W. T.
    Hao, Y. L.
    Yang, R.
    Zhang, L. C.
    ACTA MATERIALIA, 2017, 126 : 58 - 66
  • [29] BIOMECHANICAL AND HISTOLOGICAL-EVALUATION OF HYDROXYAPATITE-COATED AO/ASIF SCREWS
    DAVID, A
    POMMER, A
    EITENMULLER, J
    MUHR, G
    UNFALLCHIRURG, 1993, 96 (01): : 12 - 17
  • [30] The structure of titanium nickelide surface layers formed by pulsed electron-beam melting
    Mironov, Yu. P.
    Meisner, L. L.
    Lotkov, A. I.
    TECHNICAL PHYSICS, 2008, 53 (07) : 934 - 942