Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer

被引:14
|
作者
Abe, Kota [1 ]
Kadoya, Noriyuki [1 ]
Sato, Shinya [1 ]
Hashimoto, Shimpei [2 ]
Nakajima, Yujiro [1 ,2 ]
Miyasaka, Yuya [1 ,3 ]
Ito, Kengo [1 ]
Umezawa, Rei [1 ]
Yamamoto, Takaya [1 ]
Takahashi, Noriyoshi [1 ]
Takeda, Ken [4 ]
Jingu, Keiichi [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Radiat Oncol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
[2] Komagome Hosp, Tokyo Metropolitan Canc & Infect Dis Ctr, Dept Radiat Oncol, Bunkyo Ku, 3-18-22 Honkomagome, Tokyo 1138677, Japan
[3] Yamagata Univ, Dept Radiat Oncol, Fac Med, 2-2-2 Iidani, Yamagata 9909585, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Therapeut Radiol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
基金
日本学术振兴会;
关键词
radiotherapy; brachytherapy; model-based dose calculation algorithm; Monte Carlo simulation; cervical cancer; RATE INTRACAVITARY BRACHYTHERAPY; COLLAPSED CONE CONVOLUTION; DOSIMETRY PARAMETERS; TG-43; FORMALISM; RECOMMENDATIONS; RADIOTHERAPY; IR-192; APPLICATOR; PROTOCOL; THERAPY;
D O I
10.1093/jrr/rrx081
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer. Seven patients with cervical cancer treated using HDR-BT were studied. Tandem and ovoid applicators were used in four patients, a vaginal cylinder in one, and interstitial needles in the remaining two patients. MBDCAs were applied to the Advanced Collapsed cone Engine (ACE; Elekta, Stockholm, Sweden). All plans, which were originally calculated using TG-43, were re-calculated using both ACE and Monte Carlo (MC) simulations. Air was used as the rectal material. The mean difference in the rectum D-2cm3 between ACE(rec-air) and MCrec-air was 8.60 +/- 4.64%, whereas that in the bladder D-2cm3 was - 2.80 +/- 1.21%. Conversely, in the small group analysis (n = 4) using water instead of air as the rectal material, the mean difference in the rectum D-2cm3 between TG-43 and ACE(rec-air) was 11.87 +/- 2.65%, whereas that between TG-43 and ACE(rec-water) was 0.81 +/- 2.04%, indicating that the use of water as the rectal material reduced the difference in D-2cm3 between TG-43 and ACE. Our results suggested that the differences in the dose-volume histogram (DVH) parameters of TG-43 and ACE were large for the rectum when considerable air (gas) volume was present in it, and that this difference was reduced when the air (gas) volume was reduced. Also, ACE exhibited better dose calculation accuracy than that of TG-43 in this situation. Thus, ACE may be able to calculate the dose more accurately than TG-43 for HDR-BT in treating cervical cancers, particularly for patients with considerable air (gas) volume in the rectum.
引用
收藏
页码:198 / 206
页数:9
相关论文
共 50 条
  • [31] High-dose-rate brachytherapy in uterine cervical carcinoma
    Patel, FD
    Rai, B
    Mallick, I
    Sharma, SC
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 62 (01): : 125 - 130
  • [32] High-Dose-Rate Brachytherapy in the Curative Treatment of Patients With Localized Prostate Cancer
    Pisansky, Thomas M.
    Gold, Douglas G.
    Furutani, Keith M.
    Macdonald, O. Kenneth
    McLaren, Robert H.
    Mynderse, Lance A.
    Wilson, Torrence M.
    Hebl, James R.
    Choo, Richard
    MAYO CLINIC PROCEEDINGS, 2008, 83 (12) : 1364 - 1372
  • [33] Current controversies in high-dose-rate versus low-dose-rate brachytherapy for cervical cancer
    Stewart, Alexandra J.
    Viswanathan, Akila N.
    CANCER, 2006, 107 (05) : 908 - 915
  • [34] A Retrospective Dose Analysis of High-Dose Rate (HDR) Tandem and Ovoid and Interstitial Needle Cervical Brachytherapy Cases with a Model-Based Dose Calculation Algorithm (MBDCA)
    Radcliffe, B.
    Meltsner, S.
    Chang, Z.
    Chino, J.
    Huang, M.
    Craciunescu, O.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [35] "In vivo" Dose Measurements in High-Dose-Rate Brachytherapy Treatments for Cervical Cancer: A Project Proposal
    Reynoso Mejia, C. A.
    Buenfil Burgosa, A. E.
    Ruiz Trejo, C.
    Mota Garcia, A.
    Trejo Duran, E.
    Rodriguez Ponce, M.
    Gamboa de Buen, I.
    ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 134 - +
  • [36] Specification of absorbed dose to water using model-based dose calculation algorithms for treatment planning in brachytherapy
    Tedgren, Asa Carlsson
    Carlsson, Gudrun Alm
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (08): : 2561 - 2579
  • [37] Cumulative Dose With Organ Deformation for Cervical Cancer Treated With Multifraction High-dose-rate Brachytherapy
    Morrow, N. V.
    Ahunbay, E. E.
    Rownd, J. J.
    Li, X.
    Erickson, B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S794 - S794
  • [38] The impact of modern preoperative high-dose-rate brachytherapy in early-stage cervical cancer
    Cagetti, Leonel Varela
    Gonzague-Casabianca, Laurence
    Zemmour, Christophe
    Lambaudie, Eric
    Houvenaeghel, Gilles
    Provansal, Magalie
    Sabatier, Renaud
    Sabiani, Laura
    Blache, Guillaume
    Jauffret, Camille
    Ferre, Marjorie
    Mailleux, Hugues
    Paciencia, Maria
    Tallet, Agnes
    GYNECOLOGIC ONCOLOGY, 2021, 161 (01) : 166 - 172
  • [39] THE IMPACT OF MODERN PREOPERATIVE HIGH-DOSE-RATE BRACHYTHERAPY IN EARLY-STAGE CERVICAL CANCER
    Cagetti, Leonel Varela
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2022, 32 : A4 - A4
  • [40] Predictive value of linear-quadratic model in the treatment of cervical cancer using high-dose-rate brachytherapy
    Sood, B
    Garg, M
    Avadhani, J
    Gorla, G
    Malhotra, H
    Guha, C
    Deore, S
    Vikram, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (05): : 1377 - 1387