Impact of a commercially available model-based dose calculation algorithm on treatment planning of high-dose-rate brachytherapy in patients with cervical cancer

被引:14
|
作者
Abe, Kota [1 ]
Kadoya, Noriyuki [1 ]
Sato, Shinya [1 ]
Hashimoto, Shimpei [2 ]
Nakajima, Yujiro [1 ,2 ]
Miyasaka, Yuya [1 ,3 ]
Ito, Kengo [1 ]
Umezawa, Rei [1 ]
Yamamoto, Takaya [1 ]
Takahashi, Noriyoshi [1 ]
Takeda, Ken [4 ]
Jingu, Keiichi [1 ]
机构
[1] Tohoku Univ, Grad Sch Med, Dept Radiat Oncol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
[2] Komagome Hosp, Tokyo Metropolitan Canc & Infect Dis Ctr, Dept Radiat Oncol, Bunkyo Ku, 3-18-22 Honkomagome, Tokyo 1138677, Japan
[3] Yamagata Univ, Dept Radiat Oncol, Fac Med, 2-2-2 Iidani, Yamagata 9909585, Japan
[4] Tohoku Univ, Grad Sch Med, Dept Therapeut Radiol, Aoba Ku, 1-1 Seiryo Machi, Sendai, Miyagi 9808574, Japan
基金
日本学术振兴会;
关键词
radiotherapy; brachytherapy; model-based dose calculation algorithm; Monte Carlo simulation; cervical cancer; RATE INTRACAVITARY BRACHYTHERAPY; COLLAPSED CONE CONVOLUTION; DOSIMETRY PARAMETERS; TG-43; FORMALISM; RECOMMENDATIONS; RADIOTHERAPY; IR-192; APPLICATOR; PROTOCOL; THERAPY;
D O I
10.1093/jrr/rrx081
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
We evaluated the impact of model-based dose calculation algorithms (MBDCAs) on high-dose-rate brachytherapy (HDR-BT) treatment planning for patients with cervical cancer. Seven patients with cervical cancer treated using HDR-BT were studied. Tandem and ovoid applicators were used in four patients, a vaginal cylinder in one, and interstitial needles in the remaining two patients. MBDCAs were applied to the Advanced Collapsed cone Engine (ACE; Elekta, Stockholm, Sweden). All plans, which were originally calculated using TG-43, were re-calculated using both ACE and Monte Carlo (MC) simulations. Air was used as the rectal material. The mean difference in the rectum D-2cm3 between ACE(rec-air) and MCrec-air was 8.60 +/- 4.64%, whereas that in the bladder D-2cm3 was - 2.80 +/- 1.21%. Conversely, in the small group analysis (n = 4) using water instead of air as the rectal material, the mean difference in the rectum D-2cm3 between TG-43 and ACE(rec-air) was 11.87 +/- 2.65%, whereas that between TG-43 and ACE(rec-water) was 0.81 +/- 2.04%, indicating that the use of water as the rectal material reduced the difference in D-2cm3 between TG-43 and ACE. Our results suggested that the differences in the dose-volume histogram (DVH) parameters of TG-43 and ACE were large for the rectum when considerable air (gas) volume was present in it, and that this difference was reduced when the air (gas) volume was reduced. Also, ACE exhibited better dose calculation accuracy than that of TG-43 in this situation. Thus, ACE may be able to calculate the dose more accurately than TG-43 for HDR-BT in treating cervical cancers, particularly for patients with considerable air (gas) volume in the rectum.
引用
收藏
页码:198 / 206
页数:9
相关论文
共 50 条
  • [11] The Impact of High-Dose-Rate Brachytherapy: Measuring Clinical Outcomes in the Primary Treatment of Cervical Cancer
    Song, Jiheon
    Alyamani, Najlaa
    Bhattacharya, Gaurav
    Le, Tien
    Choan, E.
    Samant, Rajiv
    ADVANCES IN RADIATION ONCOLOGY, 2020, 5 (03) : 419 - 425
  • [12] Radiobiological Treatment Planning Evaluation of Inverse Planning Simulated Annealing for Cervical Cancer High-dose-rate Brachytherapy
    Palmqvist, Tomas
    Matias, Lucilio Dos S.
    Marthinsen, Anne B. L.
    Sundset, Marit
    Wanderas, Anne D.
    Danielsen, Signe
    Toma-Dasu, Iuliana
    ANTICANCER RESEARCH, 2015, 35 (02) : 935 - 939
  • [13] Sigmoid dose delivered by high-dose-rate brachytherapy versus low-dose-rate brachytherapy for cervical cancer
    Holloway, C. L.
    O'Farrell, D. A.
    Cormack, R. A.
    Viswanathan, A. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S165 - S165
  • [14] On the impact of improved dose calculation accuracy in clinical treatment planning for superficial high-dose-rate brachytherapy of extensive scalp lesions
    Rossi, Giulio
    Peppa, Vasiliki
    Gainey, Mark
    Kollefrath, Michael
    Sprave, Tanja
    Papagiannis, Panagiotis
    Baltas, Dimos
    PHYSICS & IMAGING IN RADIATION ONCOLOGY, 2024, 32
  • [15] Automated calculation of point A coordinates for CT-based high-dose-rate brachytherapy of cervical cancer
    Kang, Hyejoo
    Padilla, Laura
    Hasan, Yasmin
    Ai-Hallaq, Hania
    JOURNAL OF CONTEMPORARY BRACHYTHERAPY, 2017, 9 (04) : 354 - 358
  • [16] Validation of a Commercial Model-Based Collapsed Cone Dose Algorithm for High Dose-Rate Gynecological Brachytherapy Treatment Planning
    Price, M. J.
    Fontenot, J. D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [17] Dose model-based dose calculation have impact to dose distribution in brachytherapy?
    Frohlich, Georgina
    Jolesz, Zsofia
    Vizkeleti, Julia
    Bajcsay, Andras
    Major, Tibor
    Takacsi, Zoltan Nagy
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S336 - S338
  • [18] IMPACT OF OPTIMIZED TREATMENT PLANNING FOR TANDEM AND RING, AND TANDEM AND OVOIDS, USING HIGH-DOSE-RATE BRACHYTHERAPY FOR CERVICAL-CANCER
    NOYES, WR
    PETERS, NE
    THOMADSEN, BR
    FOWLER, JF
    BUCHLER, DA
    STITT, JA
    KINSELLA, TJ
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 31 (01): : 79 - 86
  • [19] Dose Delivered to the Lumbosacral Plexus From High-Dose-Rate Brachytherapy for Cervical Cancer
    Rash, Dominique
    Durbin-Johnson, Blythe
    Lim, Jihoon
    Dieterich, Sonja
    Huddleston, Adam
    Yi, Sun
    Mayadev, Jyoti
    INTERNATIONAL JOURNAL OF GYNECOLOGICAL CANCER, 2015, 25 (05) : 897 - 902
  • [20] Clinical Outcome-Driven Intelligent Automatic Treatment Planning of High-Dose-Rate Brachytherapy for Cervical Cancer
    Wang, E.
    Shen, C.
    Gonzalez, Y.
    Jia, X.