The Effectiveness of a Pneumatic Compression Belt in Reducing Respiratory Motion of Abdominal Tumors in Patients Undergoing Stereotactic Body Radiotherapy

被引:34
|
作者
Lovelock, D. Michael [1 ]
Zatcky, Joan [2 ]
Goodman, Karyn [2 ]
Yamada, Yoshiya [2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
Abdominal compression; Respiratory motion; RADIATION-THERAPY; LUNG-TUMOR; REDUCTION; ACCURACY; MOVEMENT;
D O I
10.7785/tcrt.2012.500379
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Abdominal compression using a pneumatic abdominal compression belt developed in-house has been used to reduce respiratory motion of patients undergoing hypofractionated or single fraction stereotactic radio-ablative therapy for abdominal cancers. The clinical objective of belt usage was to reduce the cranial-caudal (CC) respiratory motion of the tumor to 5 mm or less during both CT simulation and treatment. A retrospective analysis was done to determine the effectiveness of the device and associated clinical procedures to reduce the CC respiratory motion of the tumor. Materials and Methods: 42 patients treated for tumors in the liver (30), adrenal glands (6), pancreas (3) and lymph nodes (3) using high dose hypofractionated radiotherapy between 2004 and the present were eligible for analysis. All patients had 2-3 radiopaque fiducial markers implanted near the tumor prior to simulation, or had clips from prior surgery. Integral to the belt is an inflatable air bladder that is positioned over the abdomen. The pneumatic pressure was set to a level in consultation with the patient. The CC motion was measured fluoroscopically with and without pneumatic pressure. Pneumatic pressure was used at all treatments to reduce to CC motion to that achieved at simulation. Results: The mean CC motion with the belt in place, but no additional air pressure was 11.4 mm with a range of 5-20 mm. With the pressure applied, the mean CC motion was reduced to 4.4 mm with a range of 1-8 mm (P-value < 0.001). The clinical objective of reducing the CC motion of the tumor to a maximum excursion of 5 mm or less was achieved in 93% of cases. Conclusion: The use of a pneumatic compression belt and associated clinical procedures was found to result in a significant and frequently substantial reduction in the CC motion of the tumor.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 50 条
  • [31] Effectiveness of oesophageal gastric junction tumour motion with and without a pneumatic abdominal compression belt in the era of precise image-guided radiation therapy
    Li, N.
    Li, T-T
    Xiang, X-Y
    Liu, X-D
    Tang, Y.
    Li, Y-X
    Shi, J-M
    Liu, W-Y
    Ren, H.
    Fang, H.
    Chen, B.
    Lu, N-N
    Hao, J.
    Qi, S-N
    Wang, S-L
    Liu, Y-P
    Song, Y-W
    Jin, J.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2023, 21 (01): : 147 - 151
  • [32] Does the delivery technique impact the effect of respiratory motion in stereotactic ablative body radiotherapy?
    Dimitriadis, A.
    Hussein, M.
    Jafari, S.
    Kirkby, K. J.
    Nisbet, A.
    Clark, C. H.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S228 - S229
  • [33] Sarcopenia and Abdominal Fat Distribution Are Prognostic for Overall Survival in Patients with Unresectable Pancreatic Cancer Undergoing Stereotactic Body Radiotherapy
    Wu, Yufan
    Nwachukwu, Chika
    Toesca, Diego
    Liu, Yufei
    Koong, Amanda
    von Eyben, Rie
    Koong, Albert
    Chang, Daniel
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2021, 44 (10): : S58 - S58
  • [34] Effectiveness of Robotic Stereotactic Radiotherapy in Patients Undergoing Re- irradiation: A Review
    Yoosuf, Ahamed Badusha Mohamed
    Alshehri, Salem
    Aziz, Mohd Zahri Abdul
    Mansor, Syahir
    Appalanaido, Gokula Kumar
    Alqathami, Mamdouh
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (08)
  • [35] Motion management strategies and technical issues associated with stereotactic body radiotherapy of thoracic and upper abdominal tumors: A review from NRG oncology
    Brandner, Edward D.
    Chetty, Indrin J.
    Giaddui, Tawfik G.
    Xiao, Ying
    Huq, M. Saiful
    MEDICAL PHYSICS, 2017, 44 (06) : 2595 - 2612
  • [36] Preliminary Report of Stereotactic Body Radiation Therapy With Respiratory Motion Tracking for Liver Tumors
    Kang, K.
    Lim, Y.
    Jeong, H.
    Ha, I.
    Jeong, B.
    Jang, H.
    Choi, B.
    Chai, G.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S339 - S339
  • [37] Dosimetric effects of respiratory motion during stereotactic body radiation therapy of lung tumors
    Sarudis, Sebastian
    Karlsson, Anna
    Nyman, Jan
    Back, Anna
    ACTA ONCOLOGICA, 2022, 61 (08) : 1004 - 1011
  • [38] PRELIMINARY RESULTS OF STEREOTACTIC BODY RADIATION THERAPY WITH RESPIRATORY MOTION TRACKING FOR LIVER TUMORS
    Kang, Ki Mun
    Lim, Young Kyong
    Jung, Bae Kwon
    Ha, In Bong
    Chai, Gyu Young
    Min, Hyeon Ju
    Kim, Tae Ho
    Lee, Ock Jae
    Jung, Jin-Myung
    Jang, Hong Seok
    ANNALS OF ONCOLOGY, 2011, 22 : v65 - v65
  • [39] To Compress, or to Gate? Abdominal Compression versus Respiratory Gating in Pancreatic Stereotactic Body Radiation Therapy
    Campbell, W.
    Jones, B.
    Schefter, T.
    Goodman, K. A.
    Miften, M.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : S213 - S213
  • [40] Stereotactic body radiation therapy for pancreatic cancer: Assessing motion with and without abdominal compression.
    Stumpf, Priscilla K.
    Jones, Bernard
    Jain, Supriya K.
    Amini, Arya
    Thornton, Dale A.
    Dzingle, Wayne
    Schefter, Tracey E.
    JOURNAL OF CLINICAL ONCOLOGY, 2016, 34 (04)