The Effectiveness of a Pneumatic Compression Belt in Reducing Respiratory Motion of Abdominal Tumors in Patients Undergoing Stereotactic Body Radiotherapy

被引:34
|
作者
Lovelock, D. Michael [1 ]
Zatcky, Joan [2 ]
Goodman, Karyn [2 ]
Yamada, Yoshiya [2 ]
机构
[1] Mem Sloan Kettering Canc Ctr, Dept Med Phys, New York, NY 10065 USA
[2] Mem Sloan Kettering Canc Ctr, Dept Radiat Oncol, New York, NY 10065 USA
关键词
Abdominal compression; Respiratory motion; RADIATION-THERAPY; LUNG-TUMOR; REDUCTION; ACCURACY; MOVEMENT;
D O I
10.7785/tcrt.2012.500379
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Abdominal compression using a pneumatic abdominal compression belt developed in-house has been used to reduce respiratory motion of patients undergoing hypofractionated or single fraction stereotactic radio-ablative therapy for abdominal cancers. The clinical objective of belt usage was to reduce the cranial-caudal (CC) respiratory motion of the tumor to 5 mm or less during both CT simulation and treatment. A retrospective analysis was done to determine the effectiveness of the device and associated clinical procedures to reduce the CC respiratory motion of the tumor. Materials and Methods: 42 patients treated for tumors in the liver (30), adrenal glands (6), pancreas (3) and lymph nodes (3) using high dose hypofractionated radiotherapy between 2004 and the present were eligible for analysis. All patients had 2-3 radiopaque fiducial markers implanted near the tumor prior to simulation, or had clips from prior surgery. Integral to the belt is an inflatable air bladder that is positioned over the abdomen. The pneumatic pressure was set to a level in consultation with the patient. The CC motion was measured fluoroscopically with and without pneumatic pressure. Pneumatic pressure was used at all treatments to reduce to CC motion to that achieved at simulation. Results: The mean CC motion with the belt in place, but no additional air pressure was 11.4 mm with a range of 5-20 mm. With the pressure applied, the mean CC motion was reduced to 4.4 mm with a range of 1-8 mm (P-value < 0.001). The clinical objective of reducing the CC motion of the tumor to a maximum excursion of 5 mm or less was achieved in 93% of cases. Conclusion: The use of a pneumatic compression belt and associated clinical procedures was found to result in a significant and frequently substantial reduction in the CC motion of the tumor.
引用
收藏
页码:259 / 267
页数:9
相关论文
共 50 条
  • [21] Variations in magnitude and directionality of respiratory target motion throughout full treatment courses of stereotactic body radiotherapy for tumors in the liver
    Worm, Esben S.
    Hoyer, Morten
    Fledelius, Walther
    Hansen, Anders T.
    Poulsen, Per R.
    ACTA ONCOLOGICA, 2013, 52 (07) : 1437 - 1444
  • [22] Radiotherapy respiratory motion management in hepatobiliary and pancreatic malignancies: a systematic review of patient factors influencing effectiveness of motion reduction with abdominal compression
    Daly, Mairead
    McWilliam, Alan
    Radhakrishna, Ganesh
    Choudhury, Ananya
    Eccles, Cynthia L.
    ACTA ONCOLOGICA, 2022, 61 (07) : 833 - 841
  • [23] The safety and effectiveness of stereotactic body radiotherapy for central versus ultracentral lung tumors
    Chang, Joe H.
    Poon, Ian
    Erler, Darby
    Zhang, Liying
    Cheung, Patrick
    RADIOTHERAPY AND ONCOLOGY, 2018, 129 (02) : 277 - 283
  • [24] Interfraction variation in lung tumor position with abdominal compression during stereotactic body radiotherapy
    Mampuya, Wambaka Ange
    Nakamura, Mitsuhiro
    Matsuo, Yukinori
    Ueki, Nami
    Iizuka, Yusuke
    Fujimoto, Takahiro
    Yano, Shinsuke
    Monzen, Hajime
    Mizowaki, Takashi
    Hiraoka, Masahiro
    MEDICAL PHYSICS, 2013, 40 (09)
  • [25] Feasibility of abdominal fat quantification on MRI and impact on effectiveness of abdominal compression for radiotherapy motion management
    Daly, M.
    McDaid, L.
    Nelder, C.
    Chuter, R.
    Choudhury, A.
    Mcwilliam, A.
    Radhakrishna, G.
    Eccles, C. L.
    TECHNICAL INNOVATIONS & PATIENT SUPPORT IN RADIATION ONCOLOGY, 2024, 29
  • [26] Real-world effectiveness and safety of stereotactic body radiotherapy for liver metastases with different respiratory motion management techniques
    O. Hernando-Requejo
    X. Chen
    M. López
    E. Sánchez
    J. García
    P. García
    R. Alonso
    A. Montero
    R. Ciervide
    B. Álvarez
    D. Zucca
    M. García Aranda
    J. Valero
    P. Fernández Letón
    C. Rubio
    Strahlentherapie und Onkologie, 2023, 199 : 1000 - 1010
  • [27] Real-world effectiveness and safety of stereotactic body radiotherapy for liver metastases with different respiratory motion management techniques
    Hernando-Requejo, O.
    Chen, X.
    Lopez, M.
    Sanchez, E.
    Garcia, J.
    Garcia, P.
    Alonso, R.
    Montero, A.
    Ciervide, R.
    Alvarez, B.
    Zucca, D.
    Aranda, M. Garcia
    Valero, J.
    Leton, P. Fernandez
    Rubio, C.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2023, 199 (11) : 1000 - 1010
  • [28] Reduction of respiratory liver tumor motion by abdominal compression in stereotactic body frame, analyzed by tracking fiducial markers implanted in liver
    Wunderink, Wouter
    Romero, Alejandra Mendez
    De Kruijf, Willy
    De Boer, Hans
    Levendag, Peter
    Heijmen, Ben
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 71 (03): : 907 - 915
  • [29] Impact of Abdominal Compression On the Tumor Motion in the Treatment of NSCLC Using Stereotactic Body Radiosurgery
    Martin, K.
    Gomez, J.
    Singh, A.
    Malhotra, H.
    MEDICAL PHYSICS, 2012, 39 (06) : 3809 - 3809
  • [30] Kilovoltage Imaging of Implanted Fiducials to Monitor Intrafraction Motion With Abdominal Compression During Stereotactic Body Radiation Therapy for Gastrointestinal Tumors
    Yorke, Ellen
    Xiong, Ying
    Han, Qian
    Zhang, Pengpeng
    Mageras, Gikas
    Lovelock, Michael
    Pham, Hai
    Xiong, Jian-Ping
    Goodman, Karyn A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 95 (03): : 1042 - 1049