Effect of Distributed Photovoltaic Generation on Short-Circuit Currents and Fault Detection in Distribution Networks: A Practical Case Study

被引:14
|
作者
Alcala-Gonzalez, Daniel [1 ]
Garcia del Toro, Eva Maria [1 ]
Isabel Mas-Lopez, Maria [2 ]
Pindado, Santiago [3 ]
机构
[1] Univ Politecn Madrid Alfonso XII, Dept Ingn Civil Hidraul & Ordenac Terr ETSI Civil, Madrid 28014, Spain
[2] Univ Politecn Madrid Alfonso XII, Dept Ingn Civil Construcc Infraestruct & Transpor, Madrid 28014, Spain
[3] Univ Politecn Madrid, Inst Univ Microgravedad Ignacio Da Riva IDR UPM, ETSI Aeronaut & Espacio, Pza Cardenal Cisneros 3, Madrid 28040, Spain
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
关键词
coordination protection; distributed generation; photovoltaic resources; DigSILENT; RECLOSER-FUSE MISCOORDINATION; ELECTRIC VEHICLES; HIGH PENETRATION; INTEGRATION; RELIABILITY; PROTECTION; SYSTEMS; COORDINATION; OPTIMIZATION; MANAGEMENT;
D O I
10.3390/app11010405
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The increase in the installation of renewable energy sources in electrical systems has changed the power distribution networks, and a new scenario regarding protection devices has arisen. Distributed generation (DG) might produce artificial delays regarding the performance of protection devices when acting as a result of short-circuits. In this study, the preliminary research results carried out to analyze the effect of renewable energy sources (photovoltaic, wind generation, etc.) on the protection devices of a power grid are described. In order to study this problem in a well-defined scenario, a quite simple distribution network (similar to the ones present in rural areas) was selected. The distribution network was divided into three protection zones so that each of them had DG. In the Institute of Electrical and Electronic Engineers (IEEE) system 13 bus test feeder, the short-circuits with different levels of penetration were performed from 1 MVA to 3 MVA (that represent 25%, 50%, and 75% of the total load in the network). In the simulations carried out, it was observed that the installation of DG in this distribution network produced significant changes in the short-circuit currents, and the inadequate performance of the protection devices and the delay in their operating times (with differences of up to 180% in relation to the case without DG). The latter, that is, the impacts of photovoltaic DG on the reactions of protection devices in a radial distribution network, is the most relevant outcome of this work. These are the first results obtained from a research collaboration framework established by staff from ETSI Civil and the IDR/UPM Institute, to analyze the effect of renewable energy sources (as DG) on the protection devices of a radial distribution network.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [31] A rapid method for calculating short-circuit currents in distribution networks with high renewable energy penetration
    Fan, Rongqi
    Liu, Yuanlong
    Ding, Lei
    Huang, Qiang
    Cong, Wei
    Li, Yudun
    Song, Guobing
    Wei, Zhui
    Sun, Lingyan
    Wen, Jifeng
    Wang, Anning
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2025, 164
  • [32] Fault detection and analysis of distributed power system short-circuit using wavelet fractal network
    Song Yuhai
    Wang Guangjian
    Chen Xiangguo
    ICEMI 2007: PROCEEDINGS OF 2007 8TH INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS, VOL III, 2007, : 422 - +
  • [33] Space Plasma Distribution Effect of Short-Circuit Arc on Generation of Secondary Arc
    Cong, Haoxi
    Li, Qingmin
    Du, Shiyue
    Lu, Yangfei
    Li, Jinsong
    ENERGIES, 2018, 11 (04)
  • [34] Power loss minimization considering short-circuit capacity in distribution system with decentralized distributed generation
    Liu, Chang
    Tsuji, Takao
    Oyama, Tsutomu
    IEEJ TRANSACTIONS ON ELECTRICAL AND ELECTRONIC ENGINEERING, 2012, 7 (05) : 471 - 477
  • [35] Incorporating Modern Fault Ride-Through Standards into the Short-Circuit Calculation of Distribution Networks
    Pompodakis, Evangelos E.
    Katsigiannis, Yiannis
    Karapidakis, Emmanuel S.
    SENSORS, 2023, 23 (21)
  • [36] A Module Fault Component-based Classification Method for Short-circuit Faults in Distribution Networks
    Dong, Xinhua
    Zhang, Chao
    Hou, Liangxiao
    Chen, Zijian
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2019, 124 : 279 - 280
  • [37] A New Model for Short-Circuit Current Calculation of Distribution Networks Integrated with Numerous Distributed Generations
    Sun, Yiwei
    Liu, Bin
    Yue, Qing
    Wang, Yuchen
    Wang, Zhiwen
    Chen, Laijun
    2015 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2015,
  • [38] A study on effect of fault current limiter on bus voltage sag during short-circuit fault
    Polytechnic University, 4-1-1, Hashimotodai, Sagamihara 229-1196, Japan
    不详
    IEEJ Trans. Power Energy, 2008, 2 (486-492+15):
  • [39] A fast short-circuit fault detection method based on the ratio of three-phase currents square sum
    Li Y.
    Chen H.
    Shi J.
    Chen L.
    Hu Z.
    Wu X.
    1600, Power System Protection and Control Press (48): : 111 - 119
  • [40] Stator Winding InterTurn Short-Circuit Fault Detection in WRIM Using Rise and Fall Times of Stator Currents
    Bilal, Habachi
    Dyagileva, Svetlana
    Heraud, Nicolas
    Sambatra, Eric Jean Roy
    Ravelo, Blaise
    Progress In Electromagnetics Research C, 2024, 147 : 109 - 116