Effect of Distributed Photovoltaic Generation on Short-Circuit Currents and Fault Detection in Distribution Networks: A Practical Case Study

被引:14
|
作者
Alcala-Gonzalez, Daniel [1 ]
Garcia del Toro, Eva Maria [1 ]
Isabel Mas-Lopez, Maria [2 ]
Pindado, Santiago [3 ]
机构
[1] Univ Politecn Madrid Alfonso XII, Dept Ingn Civil Hidraul & Ordenac Terr ETSI Civil, Madrid 28014, Spain
[2] Univ Politecn Madrid Alfonso XII, Dept Ingn Civil Construcc Infraestruct & Transpor, Madrid 28014, Spain
[3] Univ Politecn Madrid, Inst Univ Microgravedad Ignacio Da Riva IDR UPM, ETSI Aeronaut & Espacio, Pza Cardenal Cisneros 3, Madrid 28040, Spain
来源
APPLIED SCIENCES-BASEL | 2021年 / 11卷 / 01期
关键词
coordination protection; distributed generation; photovoltaic resources; DigSILENT; RECLOSER-FUSE MISCOORDINATION; ELECTRIC VEHICLES; HIGH PENETRATION; INTEGRATION; RELIABILITY; PROTECTION; SYSTEMS; COORDINATION; OPTIMIZATION; MANAGEMENT;
D O I
10.3390/app11010405
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The increase in the installation of renewable energy sources in electrical systems has changed the power distribution networks, and a new scenario regarding protection devices has arisen. Distributed generation (DG) might produce artificial delays regarding the performance of protection devices when acting as a result of short-circuits. In this study, the preliminary research results carried out to analyze the effect of renewable energy sources (photovoltaic, wind generation, etc.) on the protection devices of a power grid are described. In order to study this problem in a well-defined scenario, a quite simple distribution network (similar to the ones present in rural areas) was selected. The distribution network was divided into three protection zones so that each of them had DG. In the Institute of Electrical and Electronic Engineers (IEEE) system 13 bus test feeder, the short-circuits with different levels of penetration were performed from 1 MVA to 3 MVA (that represent 25%, 50%, and 75% of the total load in the network). In the simulations carried out, it was observed that the installation of DG in this distribution network produced significant changes in the short-circuit currents, and the inadequate performance of the protection devices and the delay in their operating times (with differences of up to 180% in relation to the case without DG). The latter, that is, the impacts of photovoltaic DG on the reactions of protection devices in a radial distribution network, is the most relevant outcome of this work. These are the first results obtained from a research collaboration framework established by staff from ETSI Civil and the IDR/UPM Institute, to analyze the effect of renewable energy sources (as DG) on the protection devices of a radial distribution network.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [21] An Algorithm for Short-Circuit Current Interval in Distribution Networks with Inverter Type Distributed Generation Based on Affine Arithmetic
    Zhang Y.
    Du B.
    Pan B.
    Wang G.
    Xie G.
    Jiang T.
    Energy Engineering: Journal of the Association of Energy Engineering, 2024, 121 (07): : 1903 - 1920
  • [22] A Section Location Method of Single-Phase Short-Circuit Faults for Distribution Networks Containing Distributed Generators Based on Fusion Fault Confidence of Short-Circuit Current Vectors
    Xu, Shoudong
    Ouyang, Jinxin
    Chen, Jiyu
    Xiong, Xiaofu
    ELECTRONICS, 2024, 13 (09)
  • [23] Analysis Impact of Distributed Generation Injection to Profile of Voltage and Short-Circuit Fault in 20 kV Distribution Network System
    Mulyadi, Y.
    Sucita, T.
    Rahmawan, M. D.
    2ND ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2017), 2018, 288
  • [24] Comparison of static and dynamic calculations of short circuit currents in distributed generation networks
    Kontis, E. O.
    Dimos, K. S.
    Papadopoulos, T. A.
    Papadopoulos, P. N.
    Papagiannis, Grigoris K.
    2014 49TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2014,
  • [25] Probabilistic Short-Circuit Current in Active Distribution Networks Considering Low Voltage Ride-Through of Photovoltaic Generation
    Qian, Weiyan
    Zhou, Niancheng
    Wu, Jiafang
    Li, Yuze
    Wang, Qianggang
    Guo, Pan
    IEEE ACCESS, 2019, 7 : 140071 - 140083
  • [26] Impact of Distributed Rooftop Photovoltaic Systems on Short-Circuit Faults in the Supplying Low Voltage Networks
    Yengejeh, Hadi Hosseinian
    Shahnia, Farhad
    Islam, Syed M.
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (20) : 2257 - 2274
  • [27] The Contribution to Distribution Network Short-Circuit Current Level from the Connection of Distributed Generation
    Bojevic, Sreto
    Conlon, Michael F.
    2008 PROCEEDINGS OF THE 43RD INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE, VOLS 1-3, 2008, : 640 - +
  • [28] Short Circuit Current Contribution of Distributed Photovoltaic Integration on Radial Distribution Networks
    Mourad, Naidji
    Mohamed, Boudour
    2015 4TH INTERNATIONAL CONFERENCE ON ELECTRICAL ENGINEERING (ICEE), 2015, : 139 - U734
  • [29] A New Fault Location Scheme Based on Distributed Short-circuit, Current in Distribution System with DGs
    Ma, Jinjie
    Lu, Yuping
    Du, Jiao
    Lin, Xia
    2008 IEEE INTERNATIONAL CONFERENCE ON SUSTAINABLE ENERGY TECHNOLOGIES (ICSET), VOLS 1 AND 2, 2008, : 1189 - 1194
  • [30] Steady short-circuit calculation model for a photovoltaic station considering different generation units' fault characteristics
    Han W.
    Liu S.
    Xiao C.
    Liu Y.
    Song C.
    Wang Z.
    Liu, Sumei (smliu@bjfu.edu.cn), 1600, Power System Protection and Control Press (49): : 129 - 135