The validity and accuracy of wrist-worn activity monitors in lower-limb prosthesis users

被引:9
|
作者
Smith, John D. [1 ]
Guerra, Gary [2 ]
Burkholder, Brian G. [1 ]
机构
[1] Texas A&M Univ, Dept Counseling Hlth & Kinesiol, San Antonio, TX USA
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Sirindhorn Sch Prosthet & Orthot, Bangkok, Thailand
关键词
Activity tracker; fitness tracker; amputation; amputee; validity; PATIENT ACTIVITY MONITOR; PHYSICAL-ACTIVITY; ACTIVITY TRACKERS; OMRON PEDOMETERS; CEREBRAL-PALSY; OLDER-ADULTS; GAIT; RELIABILITY; WALKING; VALIDATION;
D O I
10.1080/09638288.2019.1587792
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 +/- 14.0 yrs, height = 176.1 +/- 11.6 cm, weight = 87.8 +/- 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland-Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
引用
收藏
页码:3182 / 3188
页数:7
相关论文
共 50 条
  • [31] Accuracy of wrist-worn wearable devices for determining exercise intensity
    Ho, Wei-Te
    Yang, Yi-Jen
    Li, Tung-Chou
    DIGITAL HEALTH, 2022, 8
  • [32] Validity of Wrist-Worn Activity Tracker Heart Rate Detection in Fontan Patients during Exercise
    Pierick, Alyson R.
    Burke, Kelly J.
    Prusi, Megan
    Largent, Bethany
    Yu, Sunkyung
    Lowery, Ray E.
    Duimstra, Ashley
    Hansen, Jesse E.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2025, 57 (02) : 280 - 284
  • [33] Validity of Wrist-Worn Activity Trackers for Estimating VO2max and Energy Expenditure
    Passler, Stefanie
    Bohrer, Julian
    Bloechinger, Lukas
    Senner, Veit
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (17)
  • [34] Walking activity in prosthesis-bearing lower-limb amputees
    Carmona, G. -A.
    Lacraz, A.
    Assal, M.
    REVUE DE CHIRURGIE ORTHOPEDIQUE ET REPARATRICE DE L APPAREIL MOTEUR, 2007, 93 (02): : 109 - 115
  • [35] Optical Coherence Tomography for the Investigation of Skin Adaptation in Lower-Limb Prosthesis Users
    Swanson, Eric C.
    Friedly, Janna L.
    Wang, Ruikang K.
    Sanders, Joan E.
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2021, 33 (04) : 255 - 265
  • [36] EXPERIENCE WITH A PNEUMATIC LOWER-LIMB PROSTHESIS
    LITTLE, JM
    WEEKS, A
    GOSLING, L
    MEDICAL JOURNAL OF AUSTRALIA, 1972, 1 (25) : 1300 - &
  • [37] The Relationship between Balance Confidence and Center of Pressure in Lower-Limb Prosthesis Users
    Guerra, Gary
    Smith, John D.
    Yoon, Eun-Jung
    BIOMECHANICS, 2023, 3 (04): : 561 - 570
  • [38] Construct Validity of the Both Hands Assessment Using Wrist-Worn Accelerometers
    Burgess, Andrea
    Oftedal, Stina
    Boyd, Roslyn N.
    Reedman, Sarah
    Trost, Stewart G.
    Ware, Robert S.
    Sakzewski, Leanne
    PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2024, 44 (01) : 42 - 55
  • [39] Validity of electrodermal activity-based measures of sympathetic nervous system activity from a wrist-worn device
    van der Mee, D. J.
    Gevonden, M. J.
    Westerink, J. H. D. M.
    de Geus, E. J. C.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2021, 168 : 52 - 64
  • [40] Comparison Of ActiGraph Hip Worn And Wrist Worn Activity Monitors For Assessment Of Physical Activity
    Mahar, Thomas F.
    Rowe, David A.
    Mahar, Matthew T.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 322 - 322