The validity and accuracy of wrist-worn activity monitors in lower-limb prosthesis users

被引:9
|
作者
Smith, John D. [1 ]
Guerra, Gary [2 ]
Burkholder, Brian G. [1 ]
机构
[1] Texas A&M Univ, Dept Counseling Hlth & Kinesiol, San Antonio, TX USA
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Sirindhorn Sch Prosthet & Orthot, Bangkok, Thailand
关键词
Activity tracker; fitness tracker; amputation; amputee; validity; PATIENT ACTIVITY MONITOR; PHYSICAL-ACTIVITY; ACTIVITY TRACKERS; OMRON PEDOMETERS; CEREBRAL-PALSY; OLDER-ADULTS; GAIT; RELIABILITY; WALKING; VALIDATION;
D O I
10.1080/09638288.2019.1587792
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 +/- 14.0 yrs, height = 176.1 +/- 11.6 cm, weight = 87.8 +/- 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland-Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
引用
收藏
页码:3182 / 3188
页数:7
相关论文
共 50 条
  • [21] Accuracy of Heart Rate Monitoring by Some Wrist-Worn Activity Trackers RESPONSE
    Cadmus-Bertram, Lisa
    Gangnon, Ronald
    Wirkus, Emily J.
    Thraen-Borowski, Keith M.
    Gorzelitz-Liebhauser, Jessica
    ANNALS OF INTERNAL MEDICINE, 2017, 167 (08) : 607 - 608
  • [22] Comparative Accuracy of a Wrist-Worn Activity Tracker and a Smart Shirt for Physical Activity Assessment
    Montoye, Alexander H. K.
    Mitrzyk, Joe R.
    Molesky, Monroe J.
    MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2017, 21 (04) : 201 - 211
  • [23] Classification Accuracy of the Wrist-Worn Gravity Estimator of Normal Everyday Activity Accelerometer
    Welch, Whitney A.
    Bassett, David R.
    Thompson, Dixie L.
    Freedson, Patty S.
    Staudenmayer, John W.
    John, Dinesh
    Steeves, Jeremy A.
    Conger, Scott A.
    Ceaser, Tyrone
    Howe, Cheryl A.
    Sasaki, Jeffer E.
    Fitzhugh, Eugene C.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2013, 45 (10) : 2012 - 2019
  • [24] Classification Accuracy of the Wrist-Worn GENEA Accelerometer During Structured Activity Bouts
    Welch, Whitney A.
    Bassett, David R.
    Thompson, Dixie L.
    Freedson, Patty S.
    Staudenmayer, John W.
    John, Dinesh
    Steeves, Jeremy A.
    Conger, Scott A.
    Ceaser, Tyrone
    Howe, Cheryl A.
    Sasaki, Jeffer E.
    Fitzhugh, Eugene C.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (05): : 620 - 620
  • [25] Assessing Accuracy of a Wrist-Worn Wearable Device Over Changing Levels of Activity
    Flett, Isaac L.
    Su, Yunpeng
    Cameron, Chris
    Zhou, Cong
    Pearson, Lui Holder
    Chase, J. Geoffrey
    IFAC PAPERSONLINE, 2024, 58 (24): : 409 - 414
  • [26] Impact Of Placement Of Wrist-worn Activity Monitors During The Lab And Free-living Settings
    Kang, Minsoo
    Lee, Nan Hee
    Jung, Hyun Chul
    Jeon, Soeun
    Lee, Sukho
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 294 - 294
  • [27] Reliably Measuring Habitual Free-Living Physical Activity with Hip- and Wrist-Worn Activity Monitors
    Webster, Michael D.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2008, 40 (05): : S199 - S199
  • [28] Reliability Of Free-living Physical Activity Using Hip- And Wrist-worn Activity Monitors In Adolescents
    Taylor, Katelyn J.
    Heil, Daniel P.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2012, 44 : 663 - 663
  • [29] The Feasibility and Validity of a Wearable Sensor System to Assess the Stability of High-Functioning Lower-Limb Prosthesis Users
    Miller, Kyle T.
    Russell, Molly
    Jenks, Terese
    Surratt, Kaddie
    Poretti, Kelly
    Eigenbrot, Samantha S.
    Akins, Jonathan S.
    Major, Matthew J.
    JOURNAL OF PROSTHETICS AND ORTHOTICS, 2021, 33 (03) : 213 - 222
  • [30] ACCURACY OF LED-BASED HEART RATE MONITORING ON WRIST-WORN ACTIVITY TRACKERS
    Cadmus-Bertram, Lisa
    Wirkus, Emily
    Thraen-Borowski, Keith
    Gangnon, Ronald
    Gorzelitz-Liebhauser, Jessica
    ANNALS OF BEHAVIORAL MEDICINE, 2017, 51 : S1283 - S1284