The validity and accuracy of wrist-worn activity monitors in lower-limb prosthesis users

被引:9
|
作者
Smith, John D. [1 ]
Guerra, Gary [2 ]
Burkholder, Brian G. [1 ]
机构
[1] Texas A&M Univ, Dept Counseling Hlth & Kinesiol, San Antonio, TX USA
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Sirindhorn Sch Prosthet & Orthot, Bangkok, Thailand
关键词
Activity tracker; fitness tracker; amputation; amputee; validity; PATIENT ACTIVITY MONITOR; PHYSICAL-ACTIVITY; ACTIVITY TRACKERS; OMRON PEDOMETERS; CEREBRAL-PALSY; OLDER-ADULTS; GAIT; RELIABILITY; WALKING; VALIDATION;
D O I
10.1080/09638288.2019.1587792
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: To investigate the accuracy of consumer-grade wrist-worn activity monitors during over ground walking in persons using lower-limb prosthetics. Method: Thirty-two participants using lower-limb prosthetics (age = 49.7 +/- 14.0 yrs, height = 176.1 +/- 11.6 cm, weight = 87.8 +/- 21.1 kg) were fitted with a Polar Loop, Fitbit Flex, MOVEBAND, Garmin Vivofit, and a Fitbit Charge on the right and left wrists as well as an Omron HJ-113 pedometer on the right and left hip, then walked 140 m at a self-selected pace on an indoor flat surface. Results: There were no significant differences between any of the respective right and left monitors, p > 0.05. When comparing step counts with actual step counts, Polar Loop (p = 0.001), Fitbit Flex (p = 0.001), and MOVEBAND (p = 0.001) were significantly lower than actual step counts. No significant differences existed between the remaining monitors and actual step counts (p > 0.05). Omron incurred the least error (0.6%), followed by Garmin Vivofit (1.3%) and Fitbit Charge (3.6%), with greatest error in the MOVEBAND (21.4%) and Polar Loop (13.1%). Bland-Altman plots suggest Garmin Vivofit to have the least error along with tightest agreement among the wrist-worn activity monitors Conclusion: When considering the use of consumer-grade wrist-worn activity monitors for assessing step counts in persons using lower-limb prostheses, the Garmin Vivofit seems to be the best option followed by Fitbit Charge.
引用
收藏
页码:3182 / 3188
页数:7
相关论文
共 50 条
  • [1] Accuracy of Wrist-Worn Activity Monitors during Wheelchair Use
    Smith, John
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 291 - 291
  • [2] Accuracy Of Wrist-worn Activity Monitors During Walking And Swimming
    Kwon, Eun Hye
    Smith, John D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 652 - 652
  • [3] Accuracy of Wrist-Worn Heart Rate Monitors
    Wang, Robert
    Blackburn, Gordon
    Desai, Milind
    Phelan, Dermot
    Gillinov, Lauren
    Houghtaling, Penny
    Gillinov, Marc
    JAMA CARDIOLOGY, 2017, 2 (01) : 104 - 106
  • [4] 'Validity of Wrist-worn Physical Activity Monitors to Measure Heart Rate'
    Patton, Jacelyn C.
    Shay, Terri E.
    Schmidt, Martin G.
    Massey, Brook L.
    Davis, Alex S.
    Giovannitti, Nicolas
    Funk, Merrill D.
    Thiebaud, Robert S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 369 - 370
  • [5] Accuracy of Wrist-Worn Activity Monitors during Treadmill and Elliptical Ergometry
    Smith, John D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 365 - 365
  • [6] Accuracy Of Wrist-worn Activity Monitors At Three Walking Speeds On The Treadmill
    Smith, John D.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 783 - 783
  • [7] Validity Of Wrist-worn Activity Trackers
    De Lucia, Bianca J.
    Lynch, Victoria E.
    Kowalczyk, Kayla M.
    Wade, Jessica M.
    Hudak, Jonathan R.
    Stannard, Alicja B.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2020, 52 (07) : 517 - 517
  • [8] Accuracy of Wrist-Worn Activity Monitors during Wheelchair Use and Arm Ergometry
    Kressler, Jochen
    Koeplin-Day, Joshua
    Muendle, Benedikt
    Domingo, Antoinette
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 101 - 101
  • [9] <Validity of Wrist-worn Physical Activity Monitors to Measure Heart Rate>
    Patton, Jacelyn C.
    Shay, Terri E.
    Schmidt, Martin G.
    Massey, Brook L.
    Davis, Alex S.
    Giovannitti, Nicolas
    Funk, Merrill D.
    Thiebaud, Robert S.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2015, 47 (05): : 369 - 370
  • [10] Examining The Accuracy Of Two Commercially Available Wrist-Worn Heart Rate Monitors
    Rider, Brian C.
    Tucker, Anastasia
    LaBarge, Jolie
    Moore, Madeline
    Tripure, Allison
    Brumels, Kirk
    Mahoney, Sara E.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (09) : 384 - 384