Induced Voltages Ratio-Based Algorithm for Fault Detection, and Faulted Phase and Winding Identification of a Three-Winding Power Transformer

被引:15
|
作者
Lee, Byung Eun [1 ]
Park, Jung-Wook [2 ]
Crossley, Peter A. [3 ]
Kang, Yong Cheol [4 ]
机构
[1] Chonbuk Natl Univ, Wind Energy Grid Adapt Technol Res Ctr, Chonju 561756, South Korea
[2] Yonsei Univ, Sch Elect & Elect Engn, Seoul 120749, South Korea
[3] Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
[4] Chonbuk Natl Univ, Dept Elect Engn, Wind Energy Grid Adapt Technol Res Ctr, Chonju 561756, South Korea
基金
新加坡国家研究基金会;
关键词
fault detection; faulted phase and winding identification; ratio of induced voltages; transformer protection; three-winding transformer; DIFFERENTIAL PROTECTION; CLASSIFICATION; RELAY;
D O I
10.3390/en7096031
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper proposes an algorithm for fault detection, faulted phase and winding identification of a three-winding power transformer based on the induced voltages in the electrical power system. The ratio of the induced voltages of the primary-secondary, primary-tertiary and secondary-tertiary windings is the same as the corresponding turns ratio during normal operating conditions, magnetic inrush, and over-excitation. It differs from the turns ratio during an internal fault. For a single phase and a three-phase power transformer with wye-connected windings, the induced voltages of each pair of windings are estimated. For a three-phase power transformer with delta-connected windings, the induced voltage differences are estimated to use the line currents, because the delta winding currents are practically unavailable. Six detectors are suggested for fault detection. An additional three detectors and a rule for faulted phase and winding identification are presented as well. The proposed algorithm can not only detect an internal fault, but also identify the faulted phase and winding of a three-winding power transformer. The various test results with Electromagnetic Transients Program (EMTP)-generated data show that the proposed algorithm successfully discriminates internal faults from normal operating conditions including magnetic inrush and over-excitation. This paper concludes by implementing the algorithm into a prototype relay based on a digital signal processor.
引用
收藏
页码:6031 / 6049
页数:19
相关论文
共 50 条
  • [41] Integrated diagnostic system for winding fault detection of the three-phase PMSM
    Otava, Lukas
    Buchta, Ludek
    2020 12TH INTERNATIONAL CONGRESS ON ULTRA MODERN TELECOMMUNICATIONS AND CONTROL SYSTEMS AND WORKSHOPS (ICUMT 2020), 2020, : 33 - 40
  • [42] Design of a Three-Winding Transformer for Power Decoupling of a Three-Port Series Resonant Converter for an Integrated On-Board EV Charger
    Chakraborty, Surja Sekhar
    Dey, Shuvankar
    Hatua, Kamalesh
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (11) : 14262 - 14273
  • [43] Application of support vector machines algorithm for discriminating between external fault and internal winding fault in power transformer
    1600, ICIC Express Letters Office, Tokai University, Kumamoto Campus, 9-1-1, Toroku, Kumamoto, 862-8652, Japan (08):
  • [44] An improved online minor turn-turn winding fault diagnosis in a single-phase transformer based on instantaneous induced voltages and primary current locus
    Arehpanahi, Mehdi
    Orouji, Abolfazl
    Kelk, Homayoun Meshgin
    MEASUREMENT, 2024, 226
  • [45] Detection of Transformer Winding Condition Based on Optimal K-Means Algorithm
    Yang X.
    Wang F.
    Duan R.
    He M.
    Wang, Fenghua (fhwang7723@sjtu.edu.cn), 2018, Science Press (44): : 2027 - 2032
  • [46] A Novel Three-Phase Switched Multi-Winding Power Electronic Transformer
    Gupta, Ranjan K.
    Mohapatra, Krushna K.
    Mohan, Ned
    2009 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION, VOLS 1-6, 2009, : 2956 - 2963
  • [47] Trifoliate Three-Phase Contactless Power Transformer in Case of Winding-Alignment
    Matsumoto, Hirokazu
    Neba, Yasuhiko
    Iura, Hideyasu
    Tsutsumi, Daisuke
    Ishizaka, Kouichi
    Itoh, Ryozo
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2014, 61 (01) : 53 - 62
  • [48] Detection and identification of transformer winding strain based on distributed optical fiber sensing
    Liu, Yunpeng
    Tian, Yuan
    Fan, Xiaozhou
    Bu, Yanan
    Wang, Bowen
    APPLIED OPTICS, 2018, 57 (22) : 6430 - 6438
  • [49] A Winding Deformation Detection Method based on Identification of the Nonlinear Vibration System of Transformer
    Zheng Jing
    Huang Hai
    Pan Jie
    Li Lingzhi
    Hu Yiwei
    Zhang Jiangong
    PROCEEDINGS OF THE 2017 12TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS (ICIEA), 2017, : 1909 - 1914
  • [50] Detection and localization of inter-turn fault in the HV winding of a power transformer using wavelets
    Gururaj, BI
    Satish, L
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2002, 9 (03) : 479 - 479