External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector

被引:1
|
作者
Jean, Emilie [1 ,2 ,3 ,4 ,5 ]
Lambert-Girard, Simon [6 ]
Therriault-Proulx, Francois [6 ]
Beaulieu, Luc [1 ,2 ,3 ,4 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[2] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[3] Univ Laval, CHU Quebec, Dept Radiooncol, Quebec City, PQ, Canada
[4] Univ Laval, CHU Quebec, Axe Oncol CRCHU Quebec, Quebec City, PQ, Canada
[5] CHAUR Trois Rivieres, Dept Radiooncol CIUSSS MCQ, Trois Rivieres, PQ, Canada
[6] Medscint Inc, Quebec City, PQ, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 10期
基金
加拿大自然科学与工程研究理事会;
关键词
Cerenkov radiation; hybrid detector; scintillation dosimetry; irradiation angle; QUALITY-ASSURANCE; RADIATION; LIGHT; DOSIMETRY; ELECTRON; RADIOTHERAPY; EMISSION; PHOTON; IMRT;
D O I
10.1088/1361-6560/ac6b79
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In this study, we propose a novel approach designed to take advantage of the Cerenkov light angular dependency to perform a direct measurement of an external beam irradiation angle. Approach. A Cerenkov probe composed of a 10 mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1 mm diameter transport fibre. An independent plastic scintillation detector composed of 10 mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. Angular calibration curve for fixed dose irradiations and incident angle measurements using electron and photon beams where also achieved. Main results. The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86 degrees and 1.02 degrees at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97 degrees, 1.66 degrees, 1.45 degrees and 0.95 degrees at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82 degrees. Significance. The detector offers promising perspectives as a potential tool for future quality assurance applications in radiotherapy, especially for stereotactic radiosurgery (SRS), magnetic resonance image-guided radiotherapy (MRgRT) and brachytherapy applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] A Measurement of the Scintillation Light Yield in CF4 Using a Photosensitive GEM Detector
    Azmoun, Babek
    Caccavano, Adam
    Rumore, Matthew
    Sinsheimer, John
    Smirnov, Nikolai
    Stoll, Sean
    Woody, Craig
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (04) : 2376 - 2381
  • [32] Floodmap Measurement of a Pixellated Gamma Scintillation Detector Module Using Fully Integrated Readout
    Mlotok, Viacheslav
    Ritzert, Michael
    Fischer, Peter
    Peric, Ivan
    Solf, Torsten
    Schulz, Volkmar
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1980 - +
  • [33] Experimental Determination of the Effective Point of Measurement in Electron Beams Using a Commercial Scintillation Detector
    Simiele, E.
    Smith, B.
    Culberson, W.
    MEDICAL PHYSICS, 2016, 43 (06) : 3478 - 3478
  • [34] Experimental determination of the effective point of measurement in electron beams using a commercial scintillation detector
    Simiele, E. A.
    Smith, B. R.
    Culberson, W. S.
    RADIATION MEASUREMENTS, 2017, 107 : 1 - 6
  • [35] Dose rate and beam profile measurement of proton beam using a flat panel detector
    Jeong-Min Park
    Journal of the Korean Physical Society, 2015, 67 : 1410 - 1413
  • [36] Dose rate and beam profile measurement of proton beam using a flat panel detector
    Park, Jeong-Min
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2015, 67 (08) : 1410 - 1413
  • [37] EXTERNAL-BEAM ACCELERATED PARTIAL BREAST IRRADIATION USING MULTIPLE PROTON BEAM CONFIGURATIONS
    Wang, Xiaochun
    Amos, Richard A.
    Zhang, Xiaodong
    Taddei, Phillip J.
    Woodward, Wendy A.
    Hoffman, Karen E.
    Yu, Tse Kuan
    Tereffe, Welela
    Oh, Julia
    Perkins, George H.
    Salehpour, Mohammad
    Zhang, Sean X.
    Sun, Tzou Liang
    Gillin, Michael
    Buchholz, Thomas A.
    Strom, Eric A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 80 (05): : 1464 - 1472
  • [38] The Use of Hybrid PET MRI for Identifying the Presence of Cardiac Inflammation Following External Beam Irradiation
    El-Sherif, O.
    Xhaferllari, I.
    Sykes, J.
    Butler, J.
    Battista, J.
    Wisenberg, G.
    Prato, F.
    Gaede, S.
    MEDICAL PHYSICS, 2016, 43 (06) : 3828 - 3828
  • [39] Simultaneous measurement of internal and external profiles using a ring beam device
    Wakayama, Toshitaka
    Yoshizawa, Toru
    TWO- AND THREE-DIMENSIONAL METHODS FOR INSPECTION AND METROLOGY VI, 2008, 7066
  • [40] External right-angle measurement using a two-autocollimator system
    He, Yun
    Liu, Qi
    He, Jing Jing
    He, Zhi Jie
    Hu, Ze Zhu
    Duan, Hui Zong
    Yeh, Hsien Chi
    APPLIED OPTICS, 2019, 58 (04) : 1158 - 1163