External beam irradiation angle measurement using a hybrid Cerenkov-scintillation detector

被引:1
|
作者
Jean, Emilie [1 ,2 ,3 ,4 ,5 ]
Lambert-Girard, Simon [6 ]
Therriault-Proulx, Francois [6 ]
Beaulieu, Luc [1 ,2 ,3 ,4 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ, Canada
[2] Univ Laval, Ctr Rech Canc, Quebec City, PQ, Canada
[3] Univ Laval, CHU Quebec, Dept Radiooncol, Quebec City, PQ, Canada
[4] Univ Laval, CHU Quebec, Axe Oncol CRCHU Quebec, Quebec City, PQ, Canada
[5] CHAUR Trois Rivieres, Dept Radiooncol CIUSSS MCQ, Trois Rivieres, PQ, Canada
[6] Medscint Inc, Quebec City, PQ, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2022年 / 67卷 / 10期
基金
加拿大自然科学与工程研究理事会;
关键词
Cerenkov radiation; hybrid detector; scintillation dosimetry; irradiation angle; QUALITY-ASSURANCE; RADIATION; LIGHT; DOSIMETRY; ELECTRON; RADIOTHERAPY; EMISSION; PHOTON; IMRT;
D O I
10.1088/1361-6560/ac6b79
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective. In this study, we propose a novel approach designed to take advantage of the Cerenkov light angular dependency to perform a direct measurement of an external beam irradiation angle. Approach. A Cerenkov probe composed of a 10 mm long filtered sensitive volume of clear PMMA optical fibre was built. Both filtered and raw Cerenkov signals from the transport fibre were collected through a single 1 mm diameter transport fibre. An independent plastic scintillation detector composed of 10 mm BCF12 scintillating fibre was also used for simultaneous dose measurements. A first series of measurements aimed at validating the ability to account for the Cerenkov electron energy spectrum dependency by simultaneously measuring the deposited dose, thus isolating signal variations resulting from the angular dependency. Angular calibration curve for fixed dose irradiations and incident angle measurements using electron and photon beams where also achieved. Main results. The beam nominal energy was found to have a significant impact on the shapes of the angular calibration curves. This can be linked to the electron energy spectrum dependency of the Cerenkov emission cone. Irradiation angle measurements exhibit an absolute mean error of 1.86 degrees and 1.02 degrees at 6 and 18 MV, respectively. Similar results were obtained with electron beams and the absolute mean error reaches 1.97 degrees, 1.66 degrees, 1.45 degrees and 0.95 degrees at 9, 12, 16 and 20 MeV, respectively. Reducing the numerical aperture of the Cerenkov probe leads to an increased angular dependency for the lowest energy while no major changes were observed at higher energy. This allowed irradiation angle measurements at 6 MeV with a mean absolute error of 4.82 degrees. Significance. The detector offers promising perspectives as a potential tool for future quality assurance applications in radiotherapy, especially for stereotactic radiosurgery (SRS), magnetic resonance image-guided radiotherapy (MRgRT) and brachytherapy applications.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Discrimination of charged particles in a neutral beam line by using a solid scintillation detector
    Jong-Kwan Woo
    Jewou Ko
    Dong Liu
    Journal of the Korean Physical Society, 2017, 70 : 213 - 218
  • [22] A Current-Mode Scintillation-Fiber Detector for Measurement of Neutron-Beam Profiles
    Kim, C.
    Hong, B.
    Hu, R. J.
    Jo, M.
    Lee, K. S.
    Park, S.
    Sim, K. S.
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2009, 54 (05) : 2133 - 2137
  • [23] Using machine learning to separate Cherenkov and scintillation light in hybrid neutrino detector
    Bat, A.
    JOURNAL OF INSTRUMENTATION, 2024, 19 (04):
  • [24] Long Scintillation Detector Using Composite Light Guide for β-ray Survey Measurement
    Maekawa, Tatsuyuki
    Makino, Shunichiro
    Sumita, Akio
    Goto, Tetsuo
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2011, 48 (01) : 50 - 59
  • [25] Implosion neutron yield measurement for indirect drive using a plastic scintillation detector
    Hejubian Yu Dengliziti Wuli/Nuclear Fusion and Plasma Physics, 1995, 15 (04): : 53 - 56
  • [26] A New Method for Calibration and Response Measurement of a Scintillation Detector Using Radioisotope Sources
    Nakamura, Hidehito
    Ejiri, Hiroyasu
    Kitamura, Hisashi
    RADIATION RESEARCH, 2008, 170 (06) : 811 - 814
  • [27] Velocity measurement of a vertical current of air using scintillation of laser beam
    Kagawa, N
    Numano, S
    Yoshimura, H
    Wada, O
    Koga, R
    SICE 2002: PROCEEDINGS OF THE 41ST SICE ANNUAL CONFERENCE, VOLS 1-5, 2002, : 1879 - 1880
  • [28] Feasibility study of a scintillation sheet-based detector for fluence monitoring during external photon beam radiotherapy
    Seo, Jaehyeon
    Lee, Hyunho
    Ahn, Sung Hwan
    Yoon, Myonggeun
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2023, 112
  • [29] Silicon microstrip detector irradiation using a 26 MeV proton beam
    Albergo, S.
    Chiorboli, M.
    Civinini, C.
    D'Alessandro, R.
    Macchiolo, A.
    Marchettini, C.
    Meschini, M.
    Potenza, R.
    Rovelli, A.
    Tricomi, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 583 (01): : 27 - 32
  • [30] Optical Fluorescence Monitoring during External Beam Radiation Therapy Using Cerenkov Emission as Excitation Source
    Axelsson, J.
    Davis, S.
    Gladstone, D.
    Pogue, B.
    MEDICAL PHYSICS, 2011, 38 (06)