Comparison of protein separations in capillary zone electrophoresis and capillary isoelectric focusing interfacing with electrospray mass spectrometry

被引:0
|
作者
Tang, Q
Harrata, AK
Lee, CS
机构
[1] IOWA STATE UNIV SCI & TECHNOL, DEPT CHEM, AMES, IA 50011 USA
[2] IOWA STATE UNIV SCI & TECHNOL, US DOE, AMES LAB, AMES, IA 50011 USA
来源
JOURNAL OF MASS SPECTROMETRY | 1996年 / 31卷 / 11期
关键词
capillary zone electrophoresis; capillary isoelectric focusing; electrospray ionization mass spectrometry;
D O I
10.1002/(SICI)1096-9888(199611)31:11<1284::AID-JMS422>3.3.CO;2-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-line capillary zone electrophoresis/electrospray ionization mass spectrometry (CZE-ESMS) and capillary isoelectric focusing/electrospray ionization mass spectrometry (CIEF/ESMS) were employed for protein analysis. The separation mechanisms and the detection limits of CZE/ESMS and CIEF/ESMS were compared by using model proteins including cytochrome c (horse heart), ribonuclease A (bovine pancreas), myoglobin (horse heart), carbonic anhydrase I (human erythrocytes) and beta-lactoglobulin A (bovine milk). The effect of a moving ionic boundary inside the electrophoresis capillary on the separation resolution of model proteins by CZE/ESMS and CIEF/ESMS is described. In CZE/ESMS, the formation of a moving ionic boundary due to the replacement of background electrolyte counterions with sheath liquid counterions can be eliminated by using a common counterion in both the background electrolyte and the sheath liquid. Additionally, the moving ionic boundary in CIEF/ESMS is minimized by combining cathodic mobilization with a gravity-induced hydrodynamic Baiu. The concentration detection limits of model proteins in a full-scan CIEF/ESMS analysis are in the region of 10(-7) M, similar to 20-50 times lower than that achievable using CZE/ESMS. Sample preconcentration taking place during the focusing step in CIEF is responsible for the improved detection limits.
引用
收藏
页码:1284 / 1290
页数:7
相关论文
共 50 条
  • [41] Recent advances in capillary electrophoresis/electrospray/mass spectrometry
    Analytica of Branford, Inc., Branford, CT, United States
    不详
    Electrophoresis, 12-13 (2255-2266):
  • [42] CAPILLARY ELECTROPHORESIS ELECTROSPRAY IONIZATION-MASS SPECTROMETRY
    EDMONDS, CG
    LOO, JA
    BARINAGA, CJ
    UDSETH, HR
    SMITH, RD
    JOURNAL OF CHROMATOGRAPHY, 1989, 474 (01): : 21 - 37
  • [44] Recent advances in capillary electrophoresis electrospray mass spectrometry
    Banks, JF
    ELECTROPHORESIS, 1997, 18 (12-13) : 2255 - 2266
  • [45] Interfacing microchip isoelectric focusing with on-chip electrospray ionization mass spectrometry
    Nordman, Nina
    Lauren, Susanna
    Kotiaho, Tapio
    Franssila, Sami
    Kostiainen, Risto
    Sikanen, Tiina
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1398 : 121 - 126
  • [46] CAPILLARY ZONE ELECTROPHORESIS-MASS SPECTROMETRY
    OLIVARES, JA
    NGUYEN, NT
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 204 - ANYL
  • [47] COATED CAPILLARIES AND ADDITIVES FOR THE SEPARATION OF PROTEINS BY CAPILLARY ZONE ELECTROPHORESIS AND CAPILLARY ISOELECTRIC-FOCUSING
    MAZZEO, JR
    KRULL, IS
    BIOTECHNIQUES, 1991, 10 (05) : 638 - &
  • [48] Capillary isoelectric focusing-electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry for protein characterization
    Yang, LY
    Lee, CS
    Hofstadler, SA
    Pasa-Tolic, L
    Smith, RD
    ANALYTICAL CHEMISTRY, 1998, 70 (15) : 3235 - 3241
  • [49] Interfacing capillary electrophoresis with inductively coupled plasma mass spectrometry
    Karen, I
    Caruso, JA
    LC GC-MAGAZINE OF SEPARATION SCIENCE, 1999, 17 (01): : 36 - +
  • [50] Capillary zone electrophoresis electrospray ionization mass spectrometry for the characterization of drugs of forensic interest
    Curcuruto, O
    Zaramella, A
    Hamdan, M
    Turrina, S
    Tagliaro, F
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (15) : 1487 - 1491