Comparison of protein separations in capillary zone electrophoresis and capillary isoelectric focusing interfacing with electrospray mass spectrometry

被引:0
|
作者
Tang, Q
Harrata, AK
Lee, CS
机构
[1] IOWA STATE UNIV SCI & TECHNOL, DEPT CHEM, AMES, IA 50011 USA
[2] IOWA STATE UNIV SCI & TECHNOL, US DOE, AMES LAB, AMES, IA 50011 USA
来源
JOURNAL OF MASS SPECTROMETRY | 1996年 / 31卷 / 11期
关键词
capillary zone electrophoresis; capillary isoelectric focusing; electrospray ionization mass spectrometry;
D O I
10.1002/(SICI)1096-9888(199611)31:11<1284::AID-JMS422>3.3.CO;2-V
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-line capillary zone electrophoresis/electrospray ionization mass spectrometry (CZE-ESMS) and capillary isoelectric focusing/electrospray ionization mass spectrometry (CIEF/ESMS) were employed for protein analysis. The separation mechanisms and the detection limits of CZE/ESMS and CIEF/ESMS were compared by using model proteins including cytochrome c (horse heart), ribonuclease A (bovine pancreas), myoglobin (horse heart), carbonic anhydrase I (human erythrocytes) and beta-lactoglobulin A (bovine milk). The effect of a moving ionic boundary inside the electrophoresis capillary on the separation resolution of model proteins by CZE/ESMS and CIEF/ESMS is described. In CZE/ESMS, the formation of a moving ionic boundary due to the replacement of background electrolyte counterions with sheath liquid counterions can be eliminated by using a common counterion in both the background electrolyte and the sheath liquid. Additionally, the moving ionic boundary in CIEF/ESMS is minimized by combining cathodic mobilization with a gravity-induced hydrodynamic Baiu. The concentration detection limits of model proteins in a full-scan CIEF/ESMS analysis are in the region of 10(-7) M, similar to 20-50 times lower than that achievable using CZE/ESMS. Sample preconcentration taking place during the focusing step in CIEF is responsible for the improved detection limits.
引用
收藏
页码:1284 / 1290
页数:7
相关论文
共 50 条
  • [31] Application of capillary zone electrophoresis-inductively coupled plasma mass spectrometry and capillary isoelectric focusing-inductively coupled plasma mass spectrometry for selenium speciation
    Michalke, B
    Schramel, P
    JOURNAL OF CHROMATOGRAPHY A, 1998, 807 (01) : 71 - 80
  • [32] Monitoring protein refolding induced by disulfide formation using capillary isoelectric focusing electrospray ionization mass spectrometry
    Jensen, PK
    Harrata, AK
    Lee, CS
    ANALYTICAL CHEMISTRY, 1998, 70 (10) : 2044 - 2049
  • [33] Separation of nicotine metabolites by capillary zone electrophoresis and capillary zone electrophoresis/mass spectrometry
    Palmer, ME
    Smith, RF
    Chambers, K
    Tetler, LW
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (03) : 224 - 231
  • [34] Identification of a monoclonal antibody clipping variant by cross-validation using capillary electrophoresis-sodium dodecyl sulfate, capillary zone electrophoresis-mass spectrometry and capillary isoelectric focusing-mass spectrometry
    Li, Meng
    Zhao, Xueyu
    Shen, Danfeng
    Wu, Gang
    Wang, Wenbo
    Yu, Chuanfei
    Sausen, John
    Xu, Hanmei
    Wang, Lan
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1684
  • [35] IMPROVED ELECTROSPRAY IONIZATION INTERFACE FOR CAPILLARY ZONE ELECTROPHORESIS - MASS-SPECTROMETRY
    SMITH, RD
    BARINAGA, CJ
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (18) : 1948 - 1952
  • [36] Analysis of microcystins by capillary zone electrophoresis coupling with electrospray ionization mass spectrometry
    Tong, Ping
    Zhang, Lan
    He, Yu
    Tang, Shurong
    Cheng, Jintian
    Chen, Guonan
    TALANTA, 2010, 82 (04) : 1101 - 1106
  • [37] CAPILLARY ZONE ELECTROPHORESIS MASS-SPECTROMETRY USING AN ELECTROSPRAY IONIZATION INTERFACE
    SMITH, RD
    OLIVARES, JA
    NGUYEN, NT
    UDSETH, HR
    ANALYTICAL CHEMISTRY, 1988, 60 (05) : 436 - 441
  • [38] Investigation of newly synthesized peptides by capillary zone electrophoresis electrospray mass spectrometry
    Hamdan, M
    Curcuruto, O
    Vigano, S
    Rovero, P
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (09) : 1128 - 1132
  • [39] FACTORS AFFECTING FREE ZONE ELECTROPHORESIS AND ISOELECTRIC-FOCUSING IN CAPILLARY ELECTROPHORESIS
    ZHU, MD
    HANSEN, DL
    BURD, S
    GANNON, F
    JOURNAL OF CHROMATOGRAPHY, 1989, 480 : 311 - 319
  • [40] Two-dimensional capillary electrophoresis: Capillary isoelectric focusing and capillary zone electrophoresis with laser-induced fluorescence detection
    Dickerson, Jane A.
    Ramsay, Lauren M.
    Dada, Oluwatosin O.
    Cermak, Nathan
    Dovichi, Norman J.
    ELECTROPHORESIS, 2010, 31 (15) : 2650 - 2654