Biaxial cell stimulation: A mechanical validation

被引:37
|
作者
Bieler, F. H. [1 ,2 ]
Ott, C. E. [3 ]
Thompson, M. S. [4 ]
Seidel, R. [1 ,2 ]
Ahrens, S. [3 ]
Epari, D. R. [1 ,2 ]
Wilkening, U. [5 ]
Schaser, K. D. [1 ,2 ]
Mundlos, S. [3 ,5 ]
Duda, G. N. [1 ,2 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[2] Charite, Ctr Musculoskeletal Surg, Berlin Brandenburg Ctr Regenerat Therapies, D-13353 Berlin, Germany
[3] Charite, Inst Med Genet, D-13353 Berlin, Germany
[4] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[5] Max Planck Inst Mol Genet, Berlin, Germany
关键词
Biaxial tensile strain; BioFlex; Cell deformation; Digital image correlation; DIGITAL IMAGE CORRELATION; IN-VITRO; STRAIN; SYSTEM;
D O I
10.1016/j.jbiomech.2009.04.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To analyse mechanotransduction resulting from tensile loading under defined conditions, various devices for in vitro cell stimulation have been developed. This work aimed to determine the strain distribution on the membrane of a commercially available device and its consistency with rising cycle numbers, as well as the amount of strain transferred to adherent cells. The strains and their behaviour within the stimulation device were determined using digital image correlation (DIC). The strain transferred to cells was measured on eGFP-transfected bone marrow-derived cells imaged with a fluorescence microscope. The analysis was performed by determining the coordinates of prominent positions on the cells, calculating vectors between the coordinates and their length changes with increasing applied tensile strain. The stimulation device was found to apply homogeneous (mean of standard deviations approx. 2% of mean strain) and reproducible strains in the central well area. However, on average, only half of the applied strain was transferred to the bone marrow-derived cells. Furthermore, the strain measured within the device increased significantly with an increasing number of cycles while the membrane's Young's modulus decreased, indicating permanent changes in the material during extended use. Thus, strain magnitudes do not match the system readout and results require careful interpretation, especially at high cycle numbers. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1692 / 1696
页数:5
相关论文
共 50 条
  • [31] Biaxial mechanical behaviour of textile composite reinforcements
    Boisse, P
    Buet, K
    Gasser, A
    Hanklar, S
    Launay, J
    MECANIQUE INDUSTRIELLE ET MATERIAUX, 1997, 50 (03): : 140 - 144
  • [32] Uniaxial and biaxial mechanical properties of ETFE foils
    Galliot, C.
    Luchsinger, R. H.
    POLYMER TESTING, 2011, 30 (04) : 356 - 365
  • [33] Biaxial mechanical characterization of bat wing skin
    Skulborstad, A. J.
    Swartz, S. M.
    Goulbourne, N. C.
    BIOINSPIRATION & BIOMIMETICS, 2015, 10 (03)
  • [34] Biaxial tensile mechanical properties of ETFE foil
    Wu, Minger, 1600, Tongji University (17):
  • [35] Biaxial mechanical evaluation of planar biological materials
    Sacks, MS
    JOURNAL OF ELASTICITY, 2000, 61 (1-3) : 199 - 246
  • [36] Experimental study of biaxial mechanical behaviour in fabrics
    Boisse, P
    Borr, M
    COMPTES RENDUS DE L ACADEMIE DES SCIENCES SERIE II FASCICULE B-MECANIQUE PHYSIQUE CHIMIE ASTRONOMIE, 1996, 323 (08): : 503 - 509
  • [37] Mechanical Stimulation Modulates Osteocyte Regulation of Cancer Cell Phenotype
    Verbruggen, Stefaan W.
    Thompson, Clare L.
    Duffy, Michael P.
    Lunetto, Sophia
    Nolan, Joanne
    Pearce, Oliver M. T.
    Jacobs, Christopher R.
    Knight, Martin M.
    CANCERS, 2021, 13 (12)
  • [38] In vitro mesenchymal stem cell differentiation after mechanical stimulation
    Sarraf, C. E.
    Otto, W. R.
    Eastwood, M.
    CELL PROLIFERATION, 2011, 44 (01) : 99 - 108
  • [39] Mechanical-stress microfluidic device for stem cell stimulation
    Tsao, Chia-Wen
    Yeh, Li-Chiang
    Cheng, Yu-Che
    2014 IEEE INTERNATIONAL NANOELECTRONICS CONFERENCE (INEC), 2014,
  • [40] Effects of methotrexate on human bone cell responses to mechanical stimulation
    Elliot, KJ
    Millward-Sadler, SJ
    Wright, MO
    Robb, JE
    Wallace, WHB
    Salter, DM
    RHEUMATOLOGY, 2004, 43 (10) : 1226 - 1231