Biaxial cell stimulation: A mechanical validation

被引:37
|
作者
Bieler, F. H. [1 ,2 ]
Ott, C. E. [3 ]
Thompson, M. S. [4 ]
Seidel, R. [1 ,2 ]
Ahrens, S. [3 ]
Epari, D. R. [1 ,2 ]
Wilkening, U. [5 ]
Schaser, K. D. [1 ,2 ]
Mundlos, S. [3 ,5 ]
Duda, G. N. [1 ,2 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[2] Charite, Ctr Musculoskeletal Surg, Berlin Brandenburg Ctr Regenerat Therapies, D-13353 Berlin, Germany
[3] Charite, Inst Med Genet, D-13353 Berlin, Germany
[4] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[5] Max Planck Inst Mol Genet, Berlin, Germany
关键词
Biaxial tensile strain; BioFlex; Cell deformation; Digital image correlation; DIGITAL IMAGE CORRELATION; IN-VITRO; STRAIN; SYSTEM;
D O I
10.1016/j.jbiomech.2009.04.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To analyse mechanotransduction resulting from tensile loading under defined conditions, various devices for in vitro cell stimulation have been developed. This work aimed to determine the strain distribution on the membrane of a commercially available device and its consistency with rising cycle numbers, as well as the amount of strain transferred to adherent cells. The strains and their behaviour within the stimulation device were determined using digital image correlation (DIC). The strain transferred to cells was measured on eGFP-transfected bone marrow-derived cells imaged with a fluorescence microscope. The analysis was performed by determining the coordinates of prominent positions on the cells, calculating vectors between the coordinates and their length changes with increasing applied tensile strain. The stimulation device was found to apply homogeneous (mean of standard deviations approx. 2% of mean strain) and reproducible strains in the central well area. However, on average, only half of the applied strain was transferred to the bone marrow-derived cells. Furthermore, the strain measured within the device increased significantly with an increasing number of cycles while the membrane's Young's modulus decreased, indicating permanent changes in the material during extended use. Thus, strain magnitudes do not match the system readout and results require careful interpretation, especially at high cycle numbers. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1692 / 1696
页数:5
相关论文
共 50 条
  • [21] Controlled mechanical stimulation of skin cell proliferation in vivo
    Pietramaggiori, Giorgio
    Scherer, Saja S.
    Lancerotto, Luca
    Modaressi, Ali
    Orgill, Dennis P.
    Hinz, Boris
    Pittet, Brigitte
    WOUND REPAIR AND REGENERATION, 2008, 16 (06) : A74 - A74
  • [22] Cancer Cell Invasion Is Enhanced by Applied Mechanical Stimulation
    Menon, Shalini
    Beningo, Karen A.
    PLOS ONE, 2011, 6 (02):
  • [23] Biaxial Mechanical Evaluation of Planar Biological Materials
    Michael S. Sacks
    Journal of elasticity and the physical science of solids, 2000, 61 : 199 - 246
  • [24] Uniaxial and biaxial mechanical behavior of human amnion
    Oyen, ML
    Stylianopoulos, T
    Barocas, VH
    Calvin, SE
    Cook, RF
    MECHANICAL PROPERTIES OF BIOINSPIRED AND BIOLOGICAL MATERIALS, 2005, 844 : 161 - 166
  • [25] Biaxial Mechanical Characterizations of Atrioventricular Heart Valves
    Ross, Colton
    Laurence, Devin
    Wu, Yi
    Lee, Chung-Hao
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2019, (146):
  • [26] The biaxial compression mechanical properties of crushed rock
    PengCheng Wang
    JianKun Liu
    Li Liu
    Sciences in Cold and Arid Regions, 2013, 5 (04) : 433 - 439
  • [27] Uniaxial and biaxial mechanical behavior of human amnion
    Oyen, ML
    Cook, RF
    Stylianopoulos, T
    Barocas, VH
    Calvin, SE
    Landers, DV
    JOURNAL OF MATERIALS RESEARCH, 2005, 20 (11) : 2902 - 2909
  • [28] BIAXIAL MECHANICAL-BEHAVIOR OF EXCISED EPICARDIUM
    HUMPHREY, JD
    YIN, FCP
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1988, 110 (04): : 349 - 351
  • [29] Biaxial mechanical properties of the urinary bladder wall
    Sacks, Michael S.
    Gloeckner, D. Claire
    Chancellor, Michael
    DeGroat, William C.
    Schneck, Francis X.
    American Society of Mechanical Engineers, Bioengineering Division (Publication) BED, 1999, 42 : 307 - 308
  • [30] Uniaxial and biaxial mechanical behavior of human amnion
    Michelle L. Oyen
    Robert F. Cook
    Triantafyllos Stylianopoulos
    Victor H. Barocas
    Steven E. Calvin
    Daniel V. Landers
    Journal of Materials Research, 2005, 20 : 2902 - 2909