Biaxial cell stimulation: A mechanical validation

被引:37
|
作者
Bieler, F. H. [1 ,2 ]
Ott, C. E. [3 ]
Thompson, M. S. [4 ]
Seidel, R. [1 ,2 ]
Ahrens, S. [3 ]
Epari, D. R. [1 ,2 ]
Wilkening, U. [5 ]
Schaser, K. D. [1 ,2 ]
Mundlos, S. [3 ,5 ]
Duda, G. N. [1 ,2 ]
机构
[1] Charite, Julius Wolff Inst, D-13353 Berlin, Germany
[2] Charite, Ctr Musculoskeletal Surg, Berlin Brandenburg Ctr Regenerat Therapies, D-13353 Berlin, Germany
[3] Charite, Inst Med Genet, D-13353 Berlin, Germany
[4] Univ Oxford, Dept Engn Sci, Oxford OX1 3PJ, England
[5] Max Planck Inst Mol Genet, Berlin, Germany
关键词
Biaxial tensile strain; BioFlex; Cell deformation; Digital image correlation; DIGITAL IMAGE CORRELATION; IN-VITRO; STRAIN; SYSTEM;
D O I
10.1016/j.jbiomech.2009.04.013
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
To analyse mechanotransduction resulting from tensile loading under defined conditions, various devices for in vitro cell stimulation have been developed. This work aimed to determine the strain distribution on the membrane of a commercially available device and its consistency with rising cycle numbers, as well as the amount of strain transferred to adherent cells. The strains and their behaviour within the stimulation device were determined using digital image correlation (DIC). The strain transferred to cells was measured on eGFP-transfected bone marrow-derived cells imaged with a fluorescence microscope. The analysis was performed by determining the coordinates of prominent positions on the cells, calculating vectors between the coordinates and their length changes with increasing applied tensile strain. The stimulation device was found to apply homogeneous (mean of standard deviations approx. 2% of mean strain) and reproducible strains in the central well area. However, on average, only half of the applied strain was transferred to the bone marrow-derived cells. Furthermore, the strain measured within the device increased significantly with an increasing number of cycles while the membrane's Young's modulus decreased, indicating permanent changes in the material during extended use. Thus, strain magnitudes do not match the system readout and results require careful interpretation, especially at high cycle numbers. (c) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1692 / 1696
页数:5
相关论文
共 50 条
  • [1] Bioreactor for Biaxial Mechanical Stimulation to Tissue Engineered Constructs
    Wartella, Karin A.
    Wayne, Jennifer S.
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2009, 131 (04):
  • [2] Validation of mechanical, electrical and thermal nociceptive stimulation methods in horses
    Luna, S. P. L.
    Lopes, C.
    Rosa, A. C.
    Oliveira, F. A.
    Crosignani, N.
    Taylor, P. M.
    Pantoja, J. C.
    EQUINE VETERINARY JOURNAL, 2015, 47 (05) : 609 - 614
  • [3] Design, Implementation, and Validation of a Piezoelectric Device to Study the Effects of Dynamic Mechanical Stimulation on Cell Proliferation, Migration and Morphology
    Mojena-Medina, Dahiana
    Martinez-Hernandez, Marina
    de la Fuente, Miguel
    Garcia-Isla, Guadalupe
    Posada, Julio
    Luis Jorcano, Jose
    Acedo, Pablo
    SENSORS, 2020, 20 (07)
  • [4] BIOREACTOR FOR MECHANICAL CELL STIMULATION Concept and Design
    Rocha, J. G.
    Correia, V.
    Gomez Ribelles, J. L.
    Lanceros-Mendez, S.
    Pitaes, A.
    BIODEVICES 2010: PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON BIOMEDICAL ELECTRONICS AND DEVICES, 2010, : 147 - 151
  • [5] TEMPORAL CELL MORPHOLOGY RESPONSES TO MECHANICAL STIMULATION
    Wen, Shin-Min
    Chao, Pen-Hsiu Grace
    PROCEEDINGS OF THE ASME SUMMER BIOENGINEERING CONFERENCE, PTS A AND B, 2012, : 703 - 704
  • [6] Regulation of bone cell sensitivity to mechanical stimulation
    Robling, AG
    Saxon, LK
    Burr, DB
    Turner, CH
    FASEB JOURNAL, 2006, 20 (04): : A417 - A417
  • [7] Cell orientation influences the biaxial mechanical properties of fibroblast populated collagen vessels
    Wagenseil, JE
    Elson, EL
    Okamoto, RJ
    ANNALS OF BIOMEDICAL ENGINEERING, 2004, 32 (05) : 720 - 731
  • [8] Nonlinear dynamic instability of the perovskite solar cell under biaxial mechanical impacts
    Bo, Luo
    Li, Qingya
    Chen, Xiaojun
    Gao, Wei
    ENGINEERING FAILURE ANALYSIS, 2022, 139
  • [9] Cell Orientation Influences the Biaxial Mechanical Properties of Fibroblast Populated Collagen Vessels
    Jessica E. Wagenseil
    Elliot L. Elson
    Ruth J. Okamoto
    Annals of Biomedical Engineering, 2004, 32 : 720 - 731
  • [10] Biaxial mechanical modeling of the small intestine
    Bellini, Chiara
    Glass, Paul
    Sitti, Metin
    Di Martino, Elena S.
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (08) : 1727 - 1740