Control effect for 20-story benchmark building using passive or semiactive device

被引:2
|
作者
Fukukita, A [1 ]
Saito, T [1 ]
Shiba, K [1 ]
机构
[1] Shimizu Corp, Inst Technol, Koto Ku, Tokyo 1358530, Japan
关键词
bench marks; structural control; vibration control; control methods; passive control; damping;
D O I
10.1061/(ASCE)0733-9399(2004)130:4(430)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
in this paper, we study the control effect for a 20-story benchmark building and apply passive and semiactive control devices to the building. First, we take viscous damping walls as a passive control device which consists of two outer plates and one inner plate, facing each other with a small gap filled with viscous fluid.. The damping force is related to the interstory. velocity, temperature, and the shearing area. Next,We take a variable oil damper as a semiactive control device which can produce the control forces by little electrical power. We propose a damper model in which the damping coefficient changes according to the response of the damper and control forces calculated by the controller based on a linear quadratic Gaussian control theory. It is demonstrated from the results of some simulations. that both passive device and semiactive device can effectively reduce the response of the structure in various earthquake motions.
引用
收藏
页码:430 / 436
页数:7
相关论文
共 50 条
  • [41] Loop shaping control of a model story building using smart materials
    Sethi, V.
    Song, G. B.
    Franchek, M. A.
    STRUCTURAL HEALTH MONITORING AND INTELLIGENT INFRASTRUCTURE, VOLS 1 AND 2, 2006, : 1519 - 1527
  • [42] Motion Control of Passive Haptic Device Using Wires with Servo Brakes
    Hirata, Yasuhisa
    Suzuki, Keitaro
    Kosuge, Kazuhiro
    IEEE/RSJ 2010 INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS 2010), 2010, : 3123 - 3129
  • [43] Modeling of a passive distributed vibration control device using a superposition technique
    Harne, Ryan L.
    Fuller, Chris R.
    JOURNAL OF SOUND AND VIBRATION, 2012, 331 (08) : 1859 - 1869
  • [44] GA-fuzzy control of smart base isolated benchmark building using supervisory control technique
    Kim, Hyun-Su
    Roschke, Paul N.
    ADVANCES IN ENGINEERING SOFTWARE, 2007, 38 (07) : 453 - 465
  • [45] Benchmark and parametric study of a passive flow controller (fluidic device) for the development of optimal designs using a CFD code
    Lim, Sang-Gyu
    Lee, Seok-Ho
    Kim, Han-Gon
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (05) : 1139 - 1150
  • [46] Semi-Active Control for Benchmark Building Using Innovative TMD with MRE Isolators
    Guan, Xinchun
    Zhang, Jingcai
    Li, Hui
    Ou, Jinping
    INTERNATIONAL JOURNAL OF STRUCTURAL STABILITY AND DYNAMICS, 2020, 20 (06)
  • [47] Semi-active seismic control of a 9-story benchmark building using adaptive neural-fuzzy inference system and fuzzy cooperative coevolution
    Bozorgvar, Masoud
    Zahrai, Seyed Mehdi
    SMART STRUCTURES AND SYSTEMS, 2019, 23 (01) : 1 - 14
  • [48] Loop shaping control of a model-story building using smart materials
    Sethi, Vineet
    Song, Gangbing
    Franchek, Matthew A.
    JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2008, 19 (07) : 765 - 777
  • [49] Build and Control of a Continuous Passive Motion Device using Mobile Application and Arduino
    Issa, Ahmed
    Aqel, Mohammad O. A.
    Ghaben, Suad
    Abu Asad, Areej
    Eldandooh, Kawther
    Alastal, Salwa
    Bratanov, Daniel
    2019 INTERNATIONAL CONFERENCE ON PROMISING ELECTRONIC TECHNOLOGIES (ICPET 2019), 2019, : 22 - 27
  • [50] LQR Control of Wind Excited Benchmark Building Using Variable Stiffness Tuned Mass Damper
    Deshmukh, S. N.
    Chandiramani, N. K.
    SHOCK AND VIBRATION, 2014, 2014