Control effect for 20-story benchmark building using passive or semiactive device

被引:2
|
作者
Fukukita, A [1 ]
Saito, T [1 ]
Shiba, K [1 ]
机构
[1] Shimizu Corp, Inst Technol, Koto Ku, Tokyo 1358530, Japan
关键词
bench marks; structural control; vibration control; control methods; passive control; damping;
D O I
10.1061/(ASCE)0733-9399(2004)130:4(430)
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
in this paper, we study the control effect for a 20-story benchmark building and apply passive and semiactive control devices to the building. First, we take viscous damping walls as a passive control device which consists of two outer plates and one inner plate, facing each other with a small gap filled with viscous fluid.. The damping force is related to the interstory. velocity, temperature, and the shearing area. Next,We take a variable oil damper as a semiactive control device which can produce the control forces by little electrical power. We propose a damper model in which the damping coefficient changes according to the response of the damper and control forces calculated by the controller based on a linear quadratic Gaussian control theory. It is demonstrated from the results of some simulations. that both passive device and semiactive device can effectively reduce the response of the structure in various earthquake motions.
引用
收藏
页码:430 / 436