Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study

被引:8
|
作者
Kyriakopoulos, G. [1 ,7 ]
Panagopoulos, A. [2 ]
Pasiou, E. [3 ]
Kourkoulis, S. K. [3 ]
Diamantakos, I. [4 ]
Anastopoulos, G. [1 ]
Tserpes, K. [5 ]
Tatani, I. [2 ]
Lakoumentas, J. [6 ]
Megas, P. [2 ]
机构
[1] Georgios Gennimatas Gen Hosp, Dept Orthopaed, Athens, Greece
[2] Patras Univ Hosp, Dept Adult Reconstruct, Orthopaed Clin, Patras, Greece
[3] NTUA, Sch Appl Math & Phys Sci, Dept Mech, Lab Biomech & Biomed Phys, Athens, Greece
[4] Univ Peloponnese, Sch Engn, Dept Mech Engn, Patras, Greece
[5] Univ Patras, Dept Mech Engn & Aeronaut, Lab Technol & Strength Mat, Patras, Greece
[6] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
[7] Peripheral Gen Hosp Athens Giorgos Gennimatas, Orthopaed Dept 1, Athens, Greece
关键词
Intertrochanteric fractures; Pertrochanteric; Fractures; Hip fractures; Dynamic hip screw; DHS; Cephalomedullary nailing; Gamma3; Biomechanical testing; Finite element analysis; Cut-out; Mechanical failure; Implant angle; TAD; Tip-to-apex distance; Varus reduction; Valgus reduction; TIP-APEX DISTANCE; PROXIMAL FEMORAL NAIL; TROCHANTERIC FRACTURES; LAG SCREW; RISK-FACTORS; GAMMA-NAIL; FAILURE; CUTOUT; INTRAMEDULLARY; FEMUR;
D O I
10.1016/j.injury.2022.10.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite recent advances in implants and surgical techniques, catastrophic and clinical fail-ures in the treatment of intertrochanteric fractures continue to occur, with dire consequences in an over-all frail population subset. The aim of the current study is to evaluate the effect of the factors under the surgeons' control, namely fracture reduction and implant selection, on the biomechanical behavior of fracture fixation constructs.Material-Methods: An experimental protocol was conducted with the use of instrumented sawbones, in order to validate the finite element models. The implants used were the Gamma3 (R) and DHS systems. Subsequently, a series of scenaria were considered, including various reduction and implant angle combi-nations. Data were retrieved concerning the peak cancellous bone stresses around the hip screw and the volume of cancellous bone in the femoral head stressed at critical levels, as well as implant stresses and stresses on the cortical bone of the distal fragment.Results: All stable fracture models displayed significantly decreased cancellous bone stresses and implant stresses compared to their unstable counterparts, regardless of implant used. The effect of increasing im-plant angle led to a decrease in implant stresses in all models studied, but had a beneficial effect on the stresses in the cancellous bone of the proximal fragment only in the subgroups of stable fractures with both implants and unstable fractures treated with a cephalomedullary nail (CMN). In unstable fractures anatomically reduced, the use of CMN led to significantly lower peak stresses in the cancellous bone and a smaller volume of bone stressed at critical levels. Increasing the reduction angle by 5 degrees led to a signifi-cant decrease in both peak stresses and volume of bone stressed at critical levels, more prominent in the sliding hip screw (SHS) models. Decreasing the reduction angle into varus by 5 or 10 degrees led to a significant increase in bone and implant stresses regardless of implant used.Conclusions: In stable two-part (AO31.A2) fractures the use of the SHS appears to be biomechanically equivalent to CMN. In unstable, anatomically reduced fractures, the use of CMN leads to significantly reduced cancellous bone stresses and decreased rotation of the proximal fragment during loading.A reduction in varus should be avoided at all costs. In unstable fractures treated with SHS a reduction in slight valgus appears to be biomechanically beneficial. The highest implant angle that allows for proper screw position and trajectory in the femoral head should be used for stable fractures with both implants and unstable fractures treated with Gamma3 (R).(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4072 / 4085
页数:14
相关论文
共 50 条
  • [21] Dual lag screw cephalomedullary nail versus the classic sliding hip screw for the stabilization of intertrochanteric fractures. A prospective randomized study
    Kouvidis, G.
    Sakellariou, V. I.
    Mavrogenis, A. F.
    Stavrakakis, J.
    Kampas, D.
    Galanakis, J.
    Papagelopoulos, P. J.
    Katonis, P.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2012, 7 (03): : 155 - 162
  • [22] Mobility after intertrochanteric hip fracture fixation with either a sliding hip screw or a cephalomedullary nail: Sub group analysis of a randomised trial of 1000 patients
    Ong, Joshua C. Y.
    Gill, James R.
    Parker, Martyn J.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (10): : 1709 - 1714
  • [23] Traditional and bionic dynamic hip screw fixation for the treatment of intertrochanteric fracture: a finite element analysis
    Cun, Yunwei
    Dou, Chenhou
    Tian, Siyu
    Li, Ming
    Zhu, Yanbin
    Cheng, Xiaodong
    Chen, Wei
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (03) : 551 - 559
  • [24] Traditional and bionic dynamic hip screw fixation for the treatment of intertrochanteric fracture: a finite element analysis
    Yunwei Cun
    Chenhou Dou
    Siyu Tian
    Ming Li
    Yanbin Zhu
    Xiaodong Cheng
    Wei Chen
    International Orthopaedics, 2020, 44 : 551 - 559
  • [25] Biomechanical evaluation of an improved PFNA fixation devices for intertrochanteric hip fracture with finite element analysis
    Jiang, Ziwei
    Hu, Qunsheng
    Zhao, Jingtao
    Lao, Yongsheng
    Pang, Zhihui
    Dong, Hang
    Huang, Peizhen
    Zheng, Xiaohui
    Huang, Feng
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (10): : 14888 - 14894
  • [26] Study protocol: biomechanical testing, finite element analysis and prospective, randomized, clinical study of single screw cephalomedullary nailing versus integrated dual interlocking screw fixation for unstable (31A21-3) intertrochanteric fractures in patients > 70 years old
    Panagopoulos, Andreas
    Argyropoulou, Evangelia
    Kokkalis, Zinon T.
    Parchas, Nicolaos
    Tserpes, Konstantinos
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [27] A Comparative Study of Functional Outcome Following Dynamic Hip Screw and Proximal Femoral Nailing for Intertrochanteric Fractures of the Femur
    Prakash, Anil Kumar
    Nagakumar, J. S.
    Shanthappa, Arun H.
    Venkataraman, Sagar
    Kamath, Amith
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (04)
  • [28] Dynamic hip screw versus intramedullary nailing for the treatment of A1 intertrochanteric fractures: A retrospective, comparative study and cost analysis
    Alessio-Mazzola, Mattia
    Traverso, Giacomo
    Coccarello, Francesco
    Sanguineti, Francesca
    Formica, Matteo
    JOINT DISEASES AND RELATED SURGERY, 2022, 33 (02): : 314 - 322
  • [29] A Comparative Biomechanical Analysis of Fixation Devices for Unstable Femoral Neck Fractures: The Intertan Versus Cannulated Screws or a Dynamic Hip Screw
    Rupprecht, Martin
    Grossterlinden, Lars
    Ruecker, Andreas H.
    de Oliveira, Alexander Novo
    Sellenschloh, Kay
    Nuechtern, Jakob
    Pueschel, Klaus
    Morlock, Michael
    Rueger, Johannes Maria
    Lehmann, Wolfgang
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2011, 71 (03): : 625 - 634
  • [30] Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate
    Krischak, G. D.
    Augat, P.
    Beck, A.
    Arand, M.
    Baler, B.
    Blakytny, R.
    Gebhard, F.
    Claes, L.
    CLINICAL BIOMECHANICS, 2007, 22 (10) : 1112 - 1118