Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study

被引:8
|
作者
Kyriakopoulos, G. [1 ,7 ]
Panagopoulos, A. [2 ]
Pasiou, E. [3 ]
Kourkoulis, S. K. [3 ]
Diamantakos, I. [4 ]
Anastopoulos, G. [1 ]
Tserpes, K. [5 ]
Tatani, I. [2 ]
Lakoumentas, J. [6 ]
Megas, P. [2 ]
机构
[1] Georgios Gennimatas Gen Hosp, Dept Orthopaed, Athens, Greece
[2] Patras Univ Hosp, Dept Adult Reconstruct, Orthopaed Clin, Patras, Greece
[3] NTUA, Sch Appl Math & Phys Sci, Dept Mech, Lab Biomech & Biomed Phys, Athens, Greece
[4] Univ Peloponnese, Sch Engn, Dept Mech Engn, Patras, Greece
[5] Univ Patras, Dept Mech Engn & Aeronaut, Lab Technol & Strength Mat, Patras, Greece
[6] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
[7] Peripheral Gen Hosp Athens Giorgos Gennimatas, Orthopaed Dept 1, Athens, Greece
关键词
Intertrochanteric fractures; Pertrochanteric; Fractures; Hip fractures; Dynamic hip screw; DHS; Cephalomedullary nailing; Gamma3; Biomechanical testing; Finite element analysis; Cut-out; Mechanical failure; Implant angle; TAD; Tip-to-apex distance; Varus reduction; Valgus reduction; TIP-APEX DISTANCE; PROXIMAL FEMORAL NAIL; TROCHANTERIC FRACTURES; LAG SCREW; RISK-FACTORS; GAMMA-NAIL; FAILURE; CUTOUT; INTRAMEDULLARY; FEMUR;
D O I
10.1016/j.injury.2022.10.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite recent advances in implants and surgical techniques, catastrophic and clinical fail-ures in the treatment of intertrochanteric fractures continue to occur, with dire consequences in an over-all frail population subset. The aim of the current study is to evaluate the effect of the factors under the surgeons' control, namely fracture reduction and implant selection, on the biomechanical behavior of fracture fixation constructs.Material-Methods: An experimental protocol was conducted with the use of instrumented sawbones, in order to validate the finite element models. The implants used were the Gamma3 (R) and DHS systems. Subsequently, a series of scenaria were considered, including various reduction and implant angle combi-nations. Data were retrieved concerning the peak cancellous bone stresses around the hip screw and the volume of cancellous bone in the femoral head stressed at critical levels, as well as implant stresses and stresses on the cortical bone of the distal fragment.Results: All stable fracture models displayed significantly decreased cancellous bone stresses and implant stresses compared to their unstable counterparts, regardless of implant used. The effect of increasing im-plant angle led to a decrease in implant stresses in all models studied, but had a beneficial effect on the stresses in the cancellous bone of the proximal fragment only in the subgroups of stable fractures with both implants and unstable fractures treated with a cephalomedullary nail (CMN). In unstable fractures anatomically reduced, the use of CMN led to significantly lower peak stresses in the cancellous bone and a smaller volume of bone stressed at critical levels. Increasing the reduction angle by 5 degrees led to a signifi-cant decrease in both peak stresses and volume of bone stressed at critical levels, more prominent in the sliding hip screw (SHS) models. Decreasing the reduction angle into varus by 5 or 10 degrees led to a significant increase in bone and implant stresses regardless of implant used.Conclusions: In stable two-part (AO31.A2) fractures the use of the SHS appears to be biomechanically equivalent to CMN. In unstable, anatomically reduced fractures, the use of CMN leads to significantly reduced cancellous bone stresses and decreased rotation of the proximal fragment during loading.A reduction in varus should be avoided at all costs. In unstable fractures treated with SHS a reduction in slight valgus appears to be biomechanically beneficial. The highest implant angle that allows for proper screw position and trajectory in the femoral head should be used for stable fractures with both implants and unstable fractures treated with Gamma3 (R).(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4072 / 4085
页数:14
相关论文
共 50 条
  • [11] STABLE INTERTROCHANTERIC FRACTURES OF FEMUR TREATED WITH MINIMALLY INVASIVE SLIDING HIP SCREW FIXATION - OUTCOMES, PEARLS AND PITFALLS
    Reddy, B. Sanjeev
    Bharadwaj, Sanjeevi
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2014, 3 (46): : 11242 - 11248
  • [12] Intramedullary nailing confers an increased risk of medial migration compared to dynamic hip screw fixation in unstable intertrochanteric hip fractures
    Law, Gin Way
    Wong, Yoke Rung
    Gardner, Antony
    Ng, Yau Hong
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2021, 52 (11): : 3440 - 3445
  • [13] A comparative Study of Novel Extramedullary Fixation and Dynamic Hip Screw in the Fixation of Intertrochanteric Fracture: A Finite-Element Analysis
    Ding, Kai
    Zhu, Yanbin
    Wang, Haicheng
    Li, Yonglong
    Yang, Weijie
    Cheng, Xiaodong
    Zhang, Yingze
    Chen, Wei
    Zhang, Qi
    FRONTIERS IN SURGERY, 2022, 9
  • [14] COMPARATIVE STUDY OF PROXIMAL FEMORAL NAILING AND DYNAMIC HIP SCREW FOR INTERTROCHANTERIC FRACTURES IN ADULTS
    Koduru, Satya Kumar
    Potluri, Siddharth
    Rao, C. Hanumantha
    Raghav, Srinivas T.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (35): : 2018 - 2021
  • [15] Cephalomedullary Nailing has a Higher Reoperation Rate Compared to Sliding Hip Screw Fixation in the Treatment of Intertrochanteric Femur Fractures: A Systematic Literature Review and Meta-analysis
    Amer, Kamil M.
    Congiusta, Dominick, V
    Smith, Brendan
    Jain, Kunj
    Shaath, M. Kareem
    Dalcortivo, Robert L.
    Ahmed, Irfan H.
    Vosbikian, Michael M.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (10): : 595 - 604
  • [16] Biomechanical consideration of total hip arthroplasty following failed fixation of femoral intertrochanteric fractures - A finite element analysis
    Chen, Dave W.
    Lin, Chun-Li
    Hu, Chih-Chien
    Tsai, Ming-Feng
    Lee, Mel S.
    MEDICAL ENGINEERING & PHYSICS, 2013, 35 (05) : 569 - 575
  • [17] Gotfried Percutaneous Compression Plating Compared with Sliding Hip Screw Fixation of Intertrochanteric Hip Fractures A Prospective Randomized Study
    Yang, Edward
    Qureshi, Sheeraz
    Trokhan, Shawn
    Joseph, David
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2011, 93A (10): : 942 - 947
  • [18] Biomechanical comparison of dynamic hip screw and Gamma nail for the treatment of unstable trochanteric fractures: a finite element study
    Huang, Xiaowei
    Yu, Baoqing
    Gu, Yong
    Li, Zexiang
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2017, 10 (05): : 7867 - 7874
  • [19] Study protocol: biomechanical testing, finite element analysis and prospective, randomized, clinical study of single screw cephalomedullary nailing versus integrated dual interlocking screw fixation for unstable (31A21–3) intertrochanteric fractures in patients > 70 years old
    Andreas Panagopoulos
    Evangelia Argyropoulou
    Zinon T. Kokkalis
    Nicolaos Parchas
    Konstantinos Tserpes
    Journal of Orthopaedic Surgery and Research, 18
  • [20] A COMPARATIVE STUDY OF RECONSTRUCTION NAILING VERSUS DYNAMIC HIP SCREW DEVICE IN THE SURGICAL MANAGEMENT OF INTERTROCHANTERIC FRACTURES
    Reddy, Pereddy Somashekhara
    Ponugoti, Nikhil
    Jampana, Venkata S.
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (99): : 7224 - 7230