Optimizing fixation methods for stable and unstable intertrochanteric hip fractures treated with sliding hip screw or cephalomedullary nailing: A comparative biomechanical and finite element analysis study

被引:8
|
作者
Kyriakopoulos, G. [1 ,7 ]
Panagopoulos, A. [2 ]
Pasiou, E. [3 ]
Kourkoulis, S. K. [3 ]
Diamantakos, I. [4 ]
Anastopoulos, G. [1 ]
Tserpes, K. [5 ]
Tatani, I. [2 ]
Lakoumentas, J. [6 ]
Megas, P. [2 ]
机构
[1] Georgios Gennimatas Gen Hosp, Dept Orthopaed, Athens, Greece
[2] Patras Univ Hosp, Dept Adult Reconstruct, Orthopaed Clin, Patras, Greece
[3] NTUA, Sch Appl Math & Phys Sci, Dept Mech, Lab Biomech & Biomed Phys, Athens, Greece
[4] Univ Peloponnese, Sch Engn, Dept Mech Engn, Patras, Greece
[5] Univ Patras, Dept Mech Engn & Aeronaut, Lab Technol & Strength Mat, Patras, Greece
[6] Univ Patras, Sch Med, Dept Med Phys, Patras, Greece
[7] Peripheral Gen Hosp Athens Giorgos Gennimatas, Orthopaed Dept 1, Athens, Greece
关键词
Intertrochanteric fractures; Pertrochanteric; Fractures; Hip fractures; Dynamic hip screw; DHS; Cephalomedullary nailing; Gamma3; Biomechanical testing; Finite element analysis; Cut-out; Mechanical failure; Implant angle; TAD; Tip-to-apex distance; Varus reduction; Valgus reduction; TIP-APEX DISTANCE; PROXIMAL FEMORAL NAIL; TROCHANTERIC FRACTURES; LAG SCREW; RISK-FACTORS; GAMMA-NAIL; FAILURE; CUTOUT; INTRAMEDULLARY; FEMUR;
D O I
10.1016/j.injury.2022.10.006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: Despite recent advances in implants and surgical techniques, catastrophic and clinical fail-ures in the treatment of intertrochanteric fractures continue to occur, with dire consequences in an over-all frail population subset. The aim of the current study is to evaluate the effect of the factors under the surgeons' control, namely fracture reduction and implant selection, on the biomechanical behavior of fracture fixation constructs.Material-Methods: An experimental protocol was conducted with the use of instrumented sawbones, in order to validate the finite element models. The implants used were the Gamma3 (R) and DHS systems. Subsequently, a series of scenaria were considered, including various reduction and implant angle combi-nations. Data were retrieved concerning the peak cancellous bone stresses around the hip screw and the volume of cancellous bone in the femoral head stressed at critical levels, as well as implant stresses and stresses on the cortical bone of the distal fragment.Results: All stable fracture models displayed significantly decreased cancellous bone stresses and implant stresses compared to their unstable counterparts, regardless of implant used. The effect of increasing im-plant angle led to a decrease in implant stresses in all models studied, but had a beneficial effect on the stresses in the cancellous bone of the proximal fragment only in the subgroups of stable fractures with both implants and unstable fractures treated with a cephalomedullary nail (CMN). In unstable fractures anatomically reduced, the use of CMN led to significantly lower peak stresses in the cancellous bone and a smaller volume of bone stressed at critical levels. Increasing the reduction angle by 5 degrees led to a signifi-cant decrease in both peak stresses and volume of bone stressed at critical levels, more prominent in the sliding hip screw (SHS) models. Decreasing the reduction angle into varus by 5 or 10 degrees led to a significant increase in bone and implant stresses regardless of implant used.Conclusions: In stable two-part (AO31.A2) fractures the use of the SHS appears to be biomechanically equivalent to CMN. In unstable, anatomically reduced fractures, the use of CMN leads to significantly reduced cancellous bone stresses and decreased rotation of the proximal fragment during loading.A reduction in varus should be avoided at all costs. In unstable fractures treated with SHS a reduction in slight valgus appears to be biomechanically beneficial. The highest implant angle that allows for proper screw position and trajectory in the femoral head should be used for stable fractures with both implants and unstable fractures treated with Gamma3 (R).(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:4072 / 4085
页数:14
相关论文
共 50 条
  • [1] Biomechanical Investigation of an Integrated 2-Screw Cephalomedullary Nail Versus a Sliding Hip Screw in Unstable Intertrochanteric Fractures
    Santoni, Brandon G.
    Diaz, Miguel A.
    Stoops, T. Kyle
    Lannon, Sean
    Ali, Ashley
    Sanders, Roy W.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2019, 33 (02) : 82 - 87
  • [2] Cephalomedullary nail versus sliding hip screw for unstable intertrochanteric fractures in elderly patients
    Chua, Ivan Tjun Huat
    Rajamoney, Ganesan Naidu
    Kwek, Ernest Beng Kee
    JOURNAL OF ORTHOPAEDIC SURGERY, 2013, 21 (03) : 308 - 312
  • [3] Keyhole Sliding Hip Screw Fixation for Stable Intertrochanteric Hip Fractures: A Novel Technique
    Shivashankar, B.
    Shah, Sudhir
    Kumar, Gunasekaran
    Kumar, Sandeep
    INDIAN JOURNAL OF ORTHOPAEDICS, 2022, 56 (06) : 1101 - 1107
  • [4] Keyhole Sliding Hip Screw Fixation for Stable Intertrochanteric Hip Fractures: A Novel Technique
    B. Shivashankar
    Sudhir Shah
    Gunasekaran Kumar
    Sandeep Kumar
    Indian Journal of Orthopaedics, 2022, 56 : 1101 - 1107
  • [5] Helical blade versus sliding hip screw for treatment of unstable intertrochanteric hip fractures: A biomechanical evaluation
    Strauss, Eric
    Frank, Joshua
    Lee, Jason
    Kummer, Frederick J.
    Tejwani, Nirmal
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2006, 37 (10): : 984 - 989
  • [6] Minimally Invasive Dynamic Hip Screw Fixation in Stable and Unstable Intertrochanteric Fractures
    Jana, Kanailal
    Jha, Dipak Kumar
    Chakraburtty, Tapas
    Mullick, Sunny Kumar
    Duttagupta, Swarnava
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (07) : 71 - 74
  • [7] Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: A Cadaver study
    Bong, MR
    Patel, V
    Iesaka, K
    Egol, KA
    Kummer, FJ
    Koval, KJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 56 (04): : 791 - 794
  • [8] A Biomechanical Study Comparing Helical Blade with Screw Design for Sliding Hip Fixations of Unstable Intertrochanteric Fractures
    Luo, Qiang
    Yuen, Grace
    Lau, Tak-Wing
    Yeung, Kelvin
    Leung, Frankie
    SCIENTIFIC WORLD JOURNAL, 2013,
  • [9] Design of Improved Intertrochanteric Fracture Treatment (DRIFT) Study: Protocol for Biomechanical Testing and Finite Element Analysis of Stable and Unstable Intertrochanteric Fractures Treated With Intramedullary Nailing or Dynamic Compression Screw
    Panagopoulos, Andreas
    Kyriakopoulos, Giorgos
    Anastopoulos, Giorgos
    Megas, Panagiotis
    Kourkoulis, Stavros K.
    JMIR RESEARCH PROTOCOLS, 2019, 8 (07):
  • [10] Complication Rates in Intertrochanteric Fractures: A Database Analysis Comparing Sliding Hip Screw and Cephalomedullary Nail
    Amer, Kamil M.
    Congiusta, Dominick V.
    Jain, Kunj
    Dalcortivo, Robert L.
    Benevenia, Joseph
    Vosbikian, Michael M.
    Ahmed, Irfan H.
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2024, 12 (07): : 506 - 514