Patient-specific quality assurance using machine log files analysis for stereotactic body radiation therapy (SBRT)

被引:11
|
作者
Chow, Vivian U. Y. [1 ]
Kan, Monica W. K. [1 ,2 ]
Chan, Anthony T. C. [1 ,2 ]
机构
[1] Prince Wales Hosp, Dept Clin Oncol, Hong Kong, Peoples R China
[2] Chinese Univ Hong Kong, Dept Clin Oncol, Hong Kong, Peoples R China
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2020年 / 21卷 / 11期
关键词
patient-specific QA; log file analysis; stereotactic body radiation therapy; volumetric-modulated arc therapy; plan delivery accuracy; TRAJECTORY LOG; DELIVERY; IMRT; ERRORS; IMPLEMENTATION;
D O I
10.1002/acm2.13053
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
An in-house trajectory log analysis program (LOGQA) was developed to evaluate the delivery accuracy of volumetric-modulated arc therapy (VMAT) for stereotactic body radiation therapy (SBRT). Methods have been established in LOGQA to provide analysis on dose indices, gantry angles, and multi-leaf collimator (MLC) positions. Between March 2019 and May 2020, 120 VMAT SBRT plans of various treatment sites using flattening filter-free (FFF) mode were evaluated using both LOGQA and phantom measurements. Gantry angles, dose indices, and MLC positions were extracted from log and compared with each plan. Integrated transient fluence map (ITFM) was reconstructed from log to examine the deviation of delivered fluence against the planned one. Average correlation coefficient of dose index versus gantry angle and ITFM for all patients were 1.0000, indicating that the delivered beam parameters were in good agreement with planned values. Maximum deviation of gantry angles and monitor units (MU) of all patients were less than 0.2 degree and 0.03 % respectively. Regarding MLC positions, maximum and root-mean-square (RMS) deviations from planned values were less than 0.6 mm and 0.3 mm respectively, indicating that MLC positions during delivery followed planned values in precise manner. Results of LOGQA were consistent with measurement, where all gamma-index passing rates were larger than 95 %, with 2 %/2 mm criteria. Three types of intentional errors were introduced to patient plan for software validation. LOGQA was found to recognize the introduced errors of MLC positions, gantry angles, and dose indices with magnitudes of 1 mm, 1 degree, and 5 %, respectively, which were masked in phantom measurement. LOGQA was demonstrated to have the potential to reduce or even replace patient-specific QA measurements for SBRT plan delivery provided that the frequency and amount of measurement-based machine-specific QA can be increased to ensure the log files record real values of machine parameters.
引用
收藏
页码:179 / 187
页数:9
相关论文
共 50 条
  • [31] Machine Log File and Calibration Errors-based Patient-specific Quality Assurance (QA) for Volumetric Modulated Arc Therapy (VMAT)
    Ma, Yangguang
    Mou, Xuanqin
    Beeraka, Narasimha M.
    Guo, Yuexin
    Liu, Junqi
    Dai, Jianrong
    Fan, Ruitai
    CURRENT PHARMACEUTICAL DESIGN, 2023, 29 (34) : 2738 - 2751
  • [32] Comparing log file to measurement-based patient-specific quality assurance
    Ting, Chan Li
    Inn, Tan Yun
    Wee, Tan Poh
    Leong, Leong Yuh
    Shin, Khor Jong
    Woan, Teh Mun
    Cruz, Joan Faith Loria
    Baggarley, Shaun Peter
    Huat, Ooi Kiat
    Leong, Leong Yiat
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 303 - 311
  • [33] Using an EPID for patient-specific VMAT quality assurance
    Bakhtiari, M.
    Kumaraswamy, L.
    Bailey, D. W.
    de Boer, S.
    Malhotra, H. K.
    Podgorsak, M. B.
    MEDICAL PHYSICS, 2011, 38 (03) : 1366 - 1373
  • [34] Development of pretreatment 'truly' patient-specific quality assurance procedure for stereotactic body radiotherapy using volumetric modulated arc radiotherapy
    Tachiiri, S.
    Tanaka, K.
    Tanaka, K.
    Yanagawa, M.
    Kosuga, T.
    Onishi, Y.
    Miyai, A.
    Otsu, S.
    EUROPEAN JOURNAL OF CANCER, 2013, 49 : S229 - S229
  • [35] Development of a High-Resolution End-to-End Patient-Specific Quality Assurance Tool for Rotational Stereotactic Body Radiation Therapy Deliveries Using an Electronic Portal Imaging Device
    Yang, Y.
    Han, B.
    Xing, L.
    Wang, L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E605 - E605
  • [36] Pretreatment Quality Assurance for Stereotactic Body Radiation Therapy (SBRT): Feasibility of Weekly "SBRT Rounds" in a High-Volume, Multicenter Academic Practice
    Parks, J.
    Esiashvili, N.
    Patel, P. R.
    Shelton, J. W.
    Dhabaan, A. H.
    Elder, E.
    Ghavidel, S.
    Whitaker, D.
    Higgins, K. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E546 - E546
  • [37] A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy
    Saenz, Daniel L.
    Astorga, Nestor Rodrigo
    Kirby, Neil
    Fakhreddine, Mohamad
    Rasmussen, Karl
    Stathakis, Sotirios
    Papanikolaou, Niko
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2018, 19 (05): : 625 - 631
  • [38] Verifying institutionally developed hybrid 3D-printed coaxial cylindrical phantom for patient-specific quality assurance in stereotactic body radiation therapy of hepatocellular carcinoma
    M. P. Arun Krishnan
    M. Ummal Momeen
    Radiological Physics and Technology, 2024, 17 : 230 - 237
  • [39] Verifying institutionally developed hybrid 3D-printed coaxial cylindrical phantom for patient-specific quality assurance in stereotactic body radiation therapy of hepatocellular carcinoma
    Krishnan, M. P. Arun
    Momeen, M. Ummal
    RADIOLOGICAL PHYSICS AND TECHNOLOGY, 2024, 17 (01) : 230 - 237
  • [40] Stereotactic Body Radiation Therapy (SBRT) for a Patient with a Myocardial Metastasis: A Case Report
    Dhar, Aneesh
    Donovan, Elysia
    Leong, Darryl
    Hotte, Sebastien J.
    Swaminath, Anand
    CURRENT ONCOLOGY, 2021, 28 (01) : 390 - 395