On the efficiency calibration of Si(Li) detector in the low-energy region using thick-target bremsstrahlung

被引:14
|
作者
An, Z [1 ]
Liu, MT [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Minist Educ, Key Lab Radiat Phys & Technol, Chengdu 610064, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 2002年 / 194卷 / 04期
关键词
efficiency calibration; bremsstrahlung; Si(Li) detector;
D O I
10.1016/S0168-583X(02)01033-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the efficiency calibration of a Si(Li) detector in the low-energy region down to 0.58 keV has been performed using thick-carbon-target bremsstrahlung by 19 keV electron impact. The shape of the efficiency calibration curve was determined from the thick-carbon-target bremsstrahlung spectrum, and the absolute value for the efficiency calibration was obtained from the use of(241) Am radioactive standard source. The modified Wentzel's formula for thick-target bremsstrahlung was employed and it was also compared with the most recently developed theoretical model based upon the doubly differential cross-sections for bremsstrahlung of Kissel, Quarles and Pratt. In the present calculation of theoretical bremsstrahlung, the self-absorption correction and the convolution of detector's response function with the bremsstrahlung spectrum have simultaneously been taken into account. The accuracy for the efficiency calibration in the low-energy region with the method described here was estimated to be about 6%. Moreover, the self-absorption correction calculation based upon the prescription of Wolters et al. has also been presented as an analytical factor with the accuracy of similar to1%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 50 条
  • [31] LOW-ENERGY ANGULAR DISTRIBUTION OF BREMSSTRAHLUNG FROM THICK TARGETS (T/E)
    TSIPENYUK, YM
    SOVIET ATOMIC ENERGY-USSR, 1969, 27 (05): : 1255 - +
  • [32] ABSOLUTE LOW-ENERGY PHOTOPEAK EFFICIENCY VALUES FOR NAI(TL) AND SI(LI) DETECTORS
    RIEPPO, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (08): : 839 - 844
  • [33] THICK-TARGET BOMBARDMENTS WITH HIGH-ENERGY CHARGED-PARTICLES - EXPERIMENTAL IMPROVEMENTS AND SPATIAL-DISTRIBUTION OF LOW-ENERGY SECONDARY NEUTRONS
    ENGLERT, P
    REEDY, RC
    ARNOLD, JR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 262 (2-3): : 496 - 502
  • [34] SI(LI) SPECTROMETERS FOR ELECTRONS AND LOW-ENERGY PHOTONS
    WOOD, RE
    RAO, PV
    PUCKETT, OH
    PALMS, JM
    NUCLEAR INSTRUMENTS & METHODS, 1971, 94 (02): : 245 - &
  • [35] EFFICIENCY CALIBRATION OF A SI(LI) DETECTOR AT PHOTON ENERGIES BELOW 5 KEV
    HUBRICHT, G
    KNAF, B
    PRESSER, G
    STAHLER, J
    NUCLEAR INSTRUMENTS & METHODS, 1977, 144 (02): : 359 - 360
  • [36] RELATIVE DETECTION EFFICIENCY CALIBRATION OF AGE(LI) DETECTOR AT LOW ENERGIES
    DONNELLY, DP
    WIEDENBECK, ML
    NUCLEAR INSTRUMENTS & METHODS, 1968, 64 (01): : 26 - +
  • [37] SI(LI)-DETECTOR EFFICIENCY FOR 0.7-6 KEV X-RAY-ENERGY REGION
    SHIMA, K
    NUCLEAR INSTRUMENTS & METHODS, 1979, 165 (01): : 21 - 26
  • [38] LOW-ENERGY PROTONS AS A TOOL FOR HIGH-ENERGY VERTEX DETECTOR CALIBRATION
    CACCIA, M
    CASOLI, L
    GUAZZONI, P
    MARIOLI, D
    MERONI, C
    REDAELLI, N
    TORRETTA, D
    VEGNI, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 254 (02): : 327 - 332
  • [39] Low-energy Li plus d reactions with Li target in various phases
    Yonemura, H.
    Kasagi, J.
    Honmo, M.
    Ishikawa, Y.
    Wang, T.
    Zhang, Y.
    FUSION06: REACTION MECHANISMS AND NUCLEAR STRUCTURE AT THE COULOMB BARRIER, 2006, 853 : 372 - +
  • [40] POSITION-SENSITIVE SURFACE-BARRIER SI(LI) DETECTOR FOR LOW-ENERGY GAMMA-RAYS
    BIEBL, U
    PARAK, F
    NUCLEAR INSTRUMENTS & METHODS, 1973, 112 (03): : 455 - 461