On the efficiency calibration of Si(Li) detector in the low-energy region using thick-target bremsstrahlung

被引:14
|
作者
An, Z [1 ]
Liu, MT [1 ]
机构
[1] Sichuan Univ, Inst Nucl Sci & Technol, Minist Educ, Key Lab Radiat Phys & Technol, Chengdu 610064, Peoples R China
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS | 2002年 / 194卷 / 04期
关键词
efficiency calibration; bremsstrahlung; Si(Li) detector;
D O I
10.1016/S0168-583X(02)01033-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, the efficiency calibration of a Si(Li) detector in the low-energy region down to 0.58 keV has been performed using thick-carbon-target bremsstrahlung by 19 keV electron impact. The shape of the efficiency calibration curve was determined from the thick-carbon-target bremsstrahlung spectrum, and the absolute value for the efficiency calibration was obtained from the use of(241) Am radioactive standard source. The modified Wentzel's formula for thick-target bremsstrahlung was employed and it was also compared with the most recently developed theoretical model based upon the doubly differential cross-sections for bremsstrahlung of Kissel, Quarles and Pratt. In the present calculation of theoretical bremsstrahlung, the self-absorption correction and the convolution of detector's response function with the bremsstrahlung spectrum have simultaneously been taken into account. The accuracy for the efficiency calibration in the low-energy region with the method described here was estimated to be about 6%. Moreover, the self-absorption correction calculation based upon the prescription of Wolters et al. has also been presented as an analytical factor with the accuracy of similar to1%. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:513 / 518
页数:6
相关论文
共 50 条
  • [21] BREMSSTRAHLUNG SPECTRA FROM THICK-TARGET ELECTRON-BEAMS WITH NONCOLLISIONAL ENERGY-LOSSES
    BROWN, JC
    MACKINNON, AL
    ASTROPHYSICAL JOURNAL, 1985, 292 (01): : L31 - L34
  • [22] Accurate efficiency calibration of a low-energy HPGe detector using a monochromatic x-ray source
    Plagnard, Johann
    Bobin, Christophe
    Lepy, Marie-Christine
    X-RAY SPECTROMETRY, 2007, 36 (03) : 191 - 198
  • [23] THICK-TARGET BOMBARDMENTS WITH HIGH ENERGY CHARGED PARTICLES: EXPERIMENTAL IMPROVEMENTS AND SPATIAL DISTRIBUTION OF LOW-ENERGY SECONDARY NEUTRONS.
    Englert, P.
    Reedy, R.C.
    Arnold, J.R.
    Nuclear instruments and methods in physics research, 1987, A262 (2-3): : 496 - 502
  • [24] CALIBRATION SOURCE EFFECTS IN SI(LI) DETECTOR EFFICIENCY DETERMINATIONS
    CIPOLLA, SJ
    HEWITT, MJ
    BENNIE, AG
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1976, 21 (01): : 108 - 109
  • [25] CALIBRATION SOURCE EFFECTS IN SI(LI) DETECTOR EFFICIENCY DETERMINATIONS
    CIPOLLA, SJ
    HEWITT, MJ
    NUCLEAR INSTRUMENTS & METHODS, 1976, 136 (02): : 347 - 348
  • [26] Thick-target method in the measurement of inner-shell ionization cross-sections by low-energy electron impact
    An, Z.
    Wu, Y.
    Liu, M. T.
    Duan, Y. M.
    Tang, C. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2006, 246 (02): : 281 - 287
  • [27] Measurements of the efficiency of a Si(Li) detector in the 5.5-60 keV energy region
    Budak, G
    Karabulut, A
    Simsek, Ö
    Ertugrul, M
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1999, 27 (05) : 357 - 366
  • [28] CALIBRATION OF EFFICIENCY OF A SI(LI) PHOTON SPECTROMETER IN ENERGY REGION 5 TO 125 KEV
    GEHRKE, RJ
    LOKKEN, RA
    NUCLEAR INSTRUMENTS & METHODS, 1971, 97 (02): : 219 - &
  • [29] Absolute calibration of low energy, thick target bremstrahlung
    von Neumann-Cose, P.
    Huxel, N.
    Richter, A.
    Spieler, C.
    Carroll, J.J.
    Collins, C.B.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1994, A338 (2-3) : 425 - 431
  • [30] Stopping power measurements of low-energy protons using backscattering on the thick target
    Shevchenko, VA
    METALLOFIZIKA I NOVEISHIE TEKHNOLOGII, 1995, 17 (10): : 27 - 29