A Monitoring Method of Inter-turn Insulation Fault for Dry-type Air-core Shunt Reactor

被引:0
|
作者
Zhuang, Yu [1 ]
Wang, Yonghong [1 ]
机构
[1] Harbin Univ Sci & Technol, Key Lab Engn Dielect & Its Applicat, Minist Educ, Harbin 150080, Heilongjiang, Peoples R China
关键词
dry-type air-core shunt reactor; inter-turn insulation fault; real current; impedance variation; on-line monitoring;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to solve the problem that the existing protective devices could not cut timely and accurately the dry-type air-core shunt reactor with inter-turn insulation fault, which caused the accident expanding, a new method of inter-turn insulation fault on-line monitoring based on impedance variation was proposed. Circuit model and voltage equations of inter-turn insulation fault were established and numerical analysis method was applied to analyze variation of electrical parameters in different positions. Based on these, impedance variation was determined as the monitored object and the test platform was set up to verify the test. Research results indicate that, total current basically remains unchanged, but real current increases dramatically after inter-turn insulation fault occurs. Equivalent resistance increases and equivalent reactance decreases, the change rule and the magnitude of variation are consistent between equivalent resistance and real current. The test results prove that this monitoring method is true and effective.
引用
收藏
页码:700 / 703
页数:4
相关论文
共 50 条
  • [21] Diagnostic Criterion of Turn-to-turn Overvoltage Test in Dry-type Air-core Reactor
    Guo S.
    Niu Z.
    Li H.
    Mao T.
    Ma J.
    Long K.
    Gaodianya Jishu/High Voltage Engineering, 2018, 44 (03): : 804 - 811
  • [22] Field test on the turn-to-turn insulation for 35 kV dry-type air-core reactors
    Nie, H.-Y., 1600, Editorial Department of Electric Machines and Control (18):
  • [23] High voltage dry-type air-core shunt reactors
    Papp, K.
    Sharp, M. R.
    Peelo, D. F.
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2014, 131 (08): : 349 - 354
  • [24] Diagnostic Method of Dry-type Air-core Reactors Overheating Fault Based on Monitoring TVOC
    Wang Z.
    Liu M.
    Zou J.
    Zhou W.
    Zheng D.
    Zhou, Wenjun (wjzhou@whu.edu.cn), 1600, Science Press (43): : 3756 - 3762
  • [25] Inter-Turn Fault Detection of Dry-Type Transformers Using Core-Leakage Fluxes
    Athikessavan, Subash Chandar
    Jeyasankar, Elango
    Manohar, Sai Srinivas
    Panda, Sanjib Kumar
    IEEE TRANSACTIONS ON POWER DELIVERY, 2019, 34 (04) : 1230 - 1241
  • [26] Fault Diagnosis of Dry-type Air-Core Reactor Based on Hierarchical Neural Networks
    He, Lin
    Huang, Zhengyi
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 4715 - 4719
  • [27] Research and Application of On-line Monitoring Device for Dry-type Air-core Reactor
    Zhu, Yongcan
    Xue, Zhipeng
    Zhou, Yan
    Hu, Jie
    Liu, Junjun
    Li, Zhiwen
    2019 IEEE INTERNATIONAL CONFERENCE ON ELECTRON DEVICES AND SOLID-STATE CIRCUITS (EDSSC), 2019,
  • [28] Air-core dry-type shunt reactor protection based on an alternative current alpha plane
    Silva de Almeida, Maria Leonor
    Peres, Larissa Marques
    dos Santos, Guilherme Gomes
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (01) : 34 - 44
  • [29] Breaking Overvoltage of Dry-Type Air-Core Shunt Reactors and Its Cumulative Effect on the Interturn Insulation
    Nie, Hongyan
    Liu, Xiaosheng
    Wang, Yonghong
    Yao, Yuanhang
    Gu, Zheyi
    Zhang, Chaohai
    IEEE ACCESS, 2019, 7 : 55707 - 55720
  • [30] Structure optimal design of 500 kV dry-type air-core shunt reactor based on response surface method
    Zhu, Yanjing
    Kou, Jiajun
    Zhang, Zhiyu
    Liu, Gang
    Hu, Wei
    Xie, Liang
    Zhou, Guangdong
    AIP ADVANCES, 2024, 14 (10)