Feasibility study of optimizing PET/CT acquisition protocol between image quality and radiation dose

被引:0
|
作者
Wu, TH [1 ]
Chu, TC [1 ]
Huang, YH [1 ]
Chen, CL [1 ]
Wang, SY [1 ]
Lee, JS [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu 300, Taiwan
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
D O I
10.1109/NSSMIC.2003.1352381
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In current combined PET/CT systems, high-quality CT images not only increase the diagnostic values by providing anatomic delineation of hyper- and hypo-metabolic tissues but also offer shorter transmission scanning times compared to standard PET imaging. However, this approach potentially introduces radiation burden due to the higher radiation exposure. Ideally operation protocols for routine PET/CT imaging take diagnostic values, image quality, clinical practicability, scanning time and radiation doses into consideration, but the question of how to reconcile all these factors is made debated topic in nuclear medicine today. In this study, the radiation doses delivered from a typical germanium-based and CT-based transmission scan were measured by means of an anthropomorphic Rando Alderson phantom with insertion of thermoluminescent dosimeters and the image effects of the attenuation correction with various CT acquisition protocols were compared. From the results, we found that image properties and allenuation correction data did not differ significantly by adjusted CT acquisition parameters in PET/CT imaging for reduced patient exposure about 1/26 compared to the currently used while maintaining the advantages of short scanning time and clinical practicability.
引用
收藏
页码:2410 / 2414
页数:5
相关论文
共 50 条
  • [31] CT protocols: balancing radiation dose and image quality
    Fotter, Richard
    PEDIATRIC RADIOLOGY, 2011, 41 : S215 - S216
  • [32] RADIATION DOSE AND IMAGE QUALITY IN PEDIATRIC HEAD CT
    Spampinato, Maria Vittoria
    Stalcup, Seth
    Matheus, Maria Gisele
    Byington, Kathleen
    Tyler, Michael
    Bickley, Stetson
    Tipnis, Sameer
    RADIATION PROTECTION DOSIMETRY, 2018, 182 (03) : 310 - 316
  • [33] Image quality/radiation dose considerations in pediatric CT
    Hernanz-Schulman, M
    Reese, M
    Price, RR
    Stein, SM
    Heller, RM
    Holburn, GE
    Stabin, MG
    RADIOLOGY, 2001, 221 : 246 - 246
  • [34] CT Image Quality and Radiation Dose Survey in Taiwan
    Tsai, H. Y.
    Liu, H. L.
    Chen, C. C.
    Hwang, Y. S.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [35] Advanced CT Techniques for Decreasing Radiation Dose, Reducing Sedation Requirements, and Optimizing Image Quality in Children
    Gottumukkala, Ravi V.
    Kalra, Mannudeep K.
    Tabari, Azadeh
    Otrakji, Alexi
    Gee, Michael S.
    RADIOGRAPHICS, 2019, 39 (03) : 709 - 726
  • [36] Low-Radiation Heart Inflammation PET-CT Acquisition Protocol
    Vojo, L.
    Weyermann, C.
    Hofbauer, M.
    Oblaser, T.
    Zeimpekis, K.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S771 - S772
  • [37] Estimates of the image quality and the radiation dose for head and abdomen phantom image acquisition by using dual-energy CT
    Dae-Hong Kim
    Hee-Joung Kim
    Chang-Lae Lee
    Pil-Hyun Jeon
    Won-Hyung Lee
    Sung-Soo Jeon
    Journal of the Korean Physical Society, 2012, 60 : 1150 - 1156
  • [38] Estimates of the Image Quality and the Radiation Dose for Head and Abdomen Phantom Image Acquisition by Using Dual-energy CT
    Kim, Dae-Hong
    Kim, Hee-Joung
    Lee, Chang-Lae
    Jeon, Pil-Hyun
    Lee, Won-Hyung
    Jeon, Sung-Soo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 60 (07) : 1150 - 1156
  • [39] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [40] Dependence of image quality on acquisition time for the PET/CT Biograph mCT
    Molina-Duran, Flavia
    Dinter, Dietmar
    Schoenahl, Frederic
    Schoenberg, Stefan O.
    Glatting, Gerhard