Feasibility study of optimizing PET/CT acquisition protocol between image quality and radiation dose

被引:0
|
作者
Wu, TH [1 ]
Chu, TC [1 ]
Huang, YH [1 ]
Chen, CL [1 ]
Wang, SY [1 ]
Lee, JS [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu 300, Taiwan
来源
2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5 | 2004年
关键词
D O I
10.1109/NSSMIC.2003.1352381
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In current combined PET/CT systems, high-quality CT images not only increase the diagnostic values by providing anatomic delineation of hyper- and hypo-metabolic tissues but also offer shorter transmission scanning times compared to standard PET imaging. However, this approach potentially introduces radiation burden due to the higher radiation exposure. Ideally operation protocols for routine PET/CT imaging take diagnostic values, image quality, clinical practicability, scanning time and radiation doses into consideration, but the question of how to reconcile all these factors is made debated topic in nuclear medicine today. In this study, the radiation doses delivered from a typical germanium-based and CT-based transmission scan were measured by means of an anthropomorphic Rando Alderson phantom with insertion of thermoluminescent dosimeters and the image effects of the attenuation correction with various CT acquisition protocols were compared. From the results, we found that image properties and allenuation correction data did not differ significantly by adjusted CT acquisition parameters in PET/CT imaging for reduced patient exposure about 1/26 compared to the currently used while maintaining the advantages of short scanning time and clinical practicability.
引用
收藏
页码:2410 / 2414
页数:5
相关论文
共 50 条
  • [21] Optimizing CT Dose and Image Quality for Different Patient Sizes
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2010, 37 (06) : 3333 - +
  • [22] Optimizing CT Dose and Image Quality for Different Patient Sizes
    Cody, D.
    McNitt-Gray, M.
    MEDICAL PHYSICS, 2009, 36 (06)
  • [23] Coronary CT angiography using a prospective protocol. Comparison of image quality and radiation dose between dual source CT and single source CT
    Duarte, R.
    Miranda, D.
    Fernandez-Perez, G.
    Costa, J. C.
    RADIOLOGIA, 2013, 55 (04): : 315 - 322
  • [24] Radiation dose reduction in extremity multi-detector CT: A comparison of image quality with a standard dose protocol
    Kim, Ji Na
    Park, Hee Jin
    Kim, Myung Sub
    Kook, Shin Ho
    Ham, Soo Youn
    Kim, Eugene
    Park, Se Jin
    EUROPEAN JOURNAL OF RADIOLOGY, 2021, 135
  • [25] Feasibility of a radiation dose conserving CT protocol for myocardial function assessment
    Pursnani, A.
    Lee, A.
    Mayrhofer, T.
    Panagia, M.
    Sharma, U.
    Abbara, S.
    Hoffmann, U.
    Ghoshhajra, B. B.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1040):
  • [26] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    Larson, David B.
    PEDIATRIC RADIOLOGY, 2014, 44 : 501 - 505
  • [27] Optimizing CT radiation dose based on patient size and image quality: the size-specific dose estimate method
    David B. Larson
    Pediatric Radiology, 2014, 44 : 501 - 505
  • [28] Radiation dose and image quality in head CT examinations
    Huda, W
    Chang, J
    Lieberman, KA
    Roskopf, ML
    RADIOLOGY, 2001, 221 : 160 - 160
  • [29] CT protocols: balancing radiation dose and image quality
    Richard Fotter
    Pediatric Radiology, 2011, 41 : 215 - 216
  • [30] Radiation Dose and Image Quality in Pediatric Neck CT
    Tipnis, S. V.
    Rieter, W. J.
    Patel, D.
    Stalcup, S. T.
    Matheus, M. G.
    Spampinato, M. V.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (06) : 1067 - 1073