Feasibility study of optimizing PET/CT acquisition protocol between image quality and radiation dose

被引:0
|
作者
Wu, TH [1 ]
Chu, TC [1 ]
Huang, YH [1 ]
Chen, CL [1 ]
Wang, SY [1 ]
Lee, JS [1 ]
机构
[1] Natl Tsing Hua Univ, Dept Nucl Sci, Hsinchu 300, Taiwan
关键词
D O I
10.1109/NSSMIC.2003.1352381
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In current combined PET/CT systems, high-quality CT images not only increase the diagnostic values by providing anatomic delineation of hyper- and hypo-metabolic tissues but also offer shorter transmission scanning times compared to standard PET imaging. However, this approach potentially introduces radiation burden due to the higher radiation exposure. Ideally operation protocols for routine PET/CT imaging take diagnostic values, image quality, clinical practicability, scanning time and radiation doses into consideration, but the question of how to reconcile all these factors is made debated topic in nuclear medicine today. In this study, the radiation doses delivered from a typical germanium-based and CT-based transmission scan were measured by means of an anthropomorphic Rando Alderson phantom with insertion of thermoluminescent dosimeters and the image effects of the attenuation correction with various CT acquisition protocols were compared. From the results, we found that image properties and allenuation correction data did not differ significantly by adjusted CT acquisition parameters in PET/CT imaging for reduced patient exposure about 1/26 compared to the currently used while maintaining the advantages of short scanning time and clinical practicability.
引用
收藏
页码:2410 / 2414
页数:5
相关论文
共 50 条
  • [1] Comparison of PET/CT acquisition protocols in lung carcinoma: effective radiation dose and image quality
    Eckhart, H.
    v. Langen, A.
    Vleeming, E.
    Lazarenko, S.
    Gommans, G.
    Knol, R.
    v. d. Zant, F.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2013, 40 : S151 - S151
  • [2] Optimizing CT image protocols with respect to quality and radiation dose
    Cody, D.
    Kofler, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2539 - 2539
  • [3] Influence of BMI on image quality and acquisition protocol for digital PET/CT
    Quak, E.
    Zimmerman, P.
    Lasnon, C.
    Ciappuccini, R.
    Bardet, S.
    Savigny, F.
    Foucras, G.
    Licaj, I.
    Jaudet, C.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S721 - S721
  • [4] Effect of CT acquisition parameters of spiral CT on image quality and radiation dose
    Manmadhachary, A.
    Kumar, Y. Ravi
    Krishnanand, L.
    MEASUREMENT, 2017, 103 : 18 - 26
  • [5] Optimizing CT Examination Protocols with Respect to Image Quality and Radiation Dose
    Kofler, J.
    Cody, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [6] A positron emission tomography/computed tomography (PET/CT) acquisition protocol for CT radiation dose optimization
    Wu, TH
    Chu, TC
    Huang, YH
    Chen, LK
    Mok, SP
    Lee, JK
    Yeu-Sheng, T
    Lee, JJS
    NUCLEAR MEDICINE COMMUNICATIONS, 2005, 26 (04) : 323 - 330
  • [7] Reduction of radiation dose in PET-CT: Low dose protocols and image quality
    Kim, Hyeon Sik
    Sheen, Heesoon
    Jung, Sung Pil
    Hong, Seon Pyo
    Byun, Byung-Hyun
    Min, Jung-Joon
    Lee, Byeong-il
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [8] Investigation of acquisition time for harmonization of image quality between PET/CT and PET/MRI systems: A phantom study
    Yoon, Seok Hwan
    Park, Chan Rok
    OPTIK, 2021, 244
  • [9] Optimization of the CT acquisition protocol to reduce patient dose without compromising the diagnostic quality for PET-CT: a phantom study
    Kumar, Sunil
    Pandey, Anil Kumar
    Sharma, Punit
    Malhotra, Arun
    Kumar, Rakesh
    NUCLEAR MEDICINE COMMUNICATIONS, 2012, 33 (02) : 164 - 170
  • [10] CT radiation dose and image quality
    Payne, JT