A low-cost high-fidelity ultrasound simulator with the inertial tracking of the probe pose

被引:7
|
作者
Farsoni, Saverio [1 ]
Bonfe, Marcello [1 ]
Astolfi, Luca [2 ]
机构
[1] Univ Ferrara, Dept Engn, I-44100 Ferrara, Italy
[2] Univ Ferrara, Dept Morphol Surg & Expt Med, Inst Anesthesia & Intens Care, I-44100 Ferrara, Italy
关键词
Inertial tracking; Ultrasound simulator; Sensor fusion; Medical training; Real-time algorithms; PHYSICIAN-PERFORMED ULTRASOUND; KALMAN FILTER; ROUTINE USE; ORIENTATION; TIME;
D O I
10.1016/j.conengprac.2016.11.002
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The authors developed a versatile ultrasound simulator. The proposed system achieves the main features of a high-fidelity device exploiting low-cost rapid prototyping hardware. The hand-guided ultrasound simulator probe includes a RFID reader, a 9-DOF inertial sensor unit, consisting of an accelerometer, a magnetometer and a gyroscope, and a microcontroller that performs the real-time data acquisition, the processing and the transmission of the estimated pose information to the visualization system, so that the proper ultrasound view can be generated. Since the probe orientation is the main information involved in the pose reconstruction, this work presents and investigates several tracking methods for the probe orientation, exploiting a sensor fusion technique to filter the noisy measurements coming from inertial sensors. The performances of a Kalman filter, a nonlinear complementary filter and a quaternion-based filter as inertial trackers have been tested by means of a robot manipulator, in terms of readiness, accuracy and stability of the estimated orientation signal. The results show that the nonlinear complementary filter and the quaternion-based filter match all the application requirements (RMSE <3 deg, variance <1deg(2), and settling time <0.3 s), and they involve a lower computational time with respect to the Kalman filter.
引用
收藏
页码:183 / 193
页数:11
相关论文
共 50 条
  • [21] In-utero stenting: development of a low-cost high-fidelity task trainer
    Nitsche, J. F.
    McWeeney, D. T.
    Schwendemann, W. D.
    Rose, C. H.
    Davies, N. P.
    Watson, W.
    Brost, B. C.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (06) : 720 - 723
  • [22] High-Fidelity, Low-Cost, Automated Method to Assess Laparoscopic Skills Objectively
    Gray, Richard J.
    Kahol, Kanav
    Islam, Gazi
    Smith, Marshall
    Chapital, Alyssa
    Ferrara, John
    JOURNAL OF SURGICAL EDUCATION, 2012, 69 (03) : 335 - 339
  • [23] Low-cost, high-fidelity, adaptive cancellation of periodic 60 Hz noise
    Wesson, Kyle D.
    Ochshorn, Robert M.
    Land, Bruce R.
    JOURNAL OF NEUROSCIENCE METHODS, 2009, 185 (01) : 50 - 55
  • [24] DESIGN AND VALIDATION OF A LOW-COST, HIGH-FIDELITY MODEL FOR RALP URETHROVESICAL ANASTOMOSIS
    Johnson, Brett
    Timberlake, Matthew
    Sorokin, Igor
    Cadeddu, Jeffrey
    Gahan, Jeffrey
    JOURNAL OF UROLOGY, 2018, 199 (04): : E822 - E822
  • [25] High-Fidelity Low-Cost Electronic Current Sensor for Utility Power Metering
    McNeill, Neville
    Dymond, Harry
    Mellor, Philip H.
    IEEE TRANSACTIONS ON POWER DELIVERY, 2011, 26 (04) : 2309 - 2317
  • [26] Special Issue on Credible High-Fidelity and Low-Cost Simulations in Computational Engineering
    Giacomini, Matteo
    Veroy, Karen
    Diez, Pedro
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2020, 121 (23) : 5151 - 5152
  • [27] A high-fidelity low-cost aerodynamic model using proper orthogonal decomposition
    Mifsud, M. J.
    Shaw, S. T.
    MacManus, D. G.
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN FLUIDS, 2010, 63 (04) : 468 - 494
  • [28] Development of a Low-Cost, High-Fidelity, Reusable Model to Simulate Clamshell Thoracotomy
    Clifford, Ethan
    Stourton, Frederick
    Willers, Johann
    Colucci, Gianluca
    SURGICAL INNOVATION, 2023, 30 (06) : 739 - 744
  • [29] Nursing and midwifery simulation training with a newly developed low-cost high-fidelity placenta simulator: a collaboration between Italy and Ethiopia
    Ferrari, Amerigo
    Maglio, Sabina
    Tamirat, Selamawit
    Tesfaye, Moges
    Wolde, Melaku
    Manenti, Fabio
    Facci, Enzo
    Corazza, Ilaria
    Tognarelli, Selene
    Vainieri, Milena
    Menciassi, Arianna
    BMC MEDICAL EDUCATION, 2024, 24 (01)
  • [30] Three-dimensional printing of a low-cost, high-fidelity laryngeal dissection station
    Maguire, Sharon K.
    Razavi, Christopher
    Sevimli, Yunus
    Akst, Lee M.
    LARYNGOSCOPE, 2018, 128 (04): : 944 - 947