High-Fidelity Low-Cost Electronic Current Sensor for Utility Power Metering

被引:12
|
作者
McNeill, Neville [1 ]
Dymond, Harry [1 ]
Mellor, Philip H. [1 ]
机构
[1] Univ Bristol, Dept Elect & Elect Engn, Bristol BS8 1UB, Avon, England
关键词
Current sensor; current transformer (CT); smart meter; COMPENSATION; BANDWIDTH;
D O I
10.1109/TPWRD.2011.2159998
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The design of a high-fidelity electronic current sensor for utility power-metering applications is described. The sensor is based around a current transformer with a low-permeability core material in order to yield a high dc tolerance and improved immunity to extraneous dc magnetic fields. The transformer is configured with a flux-change sense winding and feedforward of the voltage developed across the secondary winding and burden resistances. This minimizes the error due to magnetizing current which would otherwise be high with a low-permeability core material. Experimental results are given for a 60-A sensor designed for single-phase 50- and 60-Hz systems. Measured phase error is less than 0.6 at 50 Hz with 60-A dc current superimposed onto the current under measurement. No Hall-effect sensors or core-gapping operations are required. Combined with simple analog electronic circuitry, this provides a low-cost solution.
引用
收藏
页码:2309 / 2317
页数:9
相关论文
共 50 条
  • [1] A High-Fidelity, Low-Cost Visuotactile Sensor for Rolling Tactile Perception
    Xie, Lintao
    Yu, Guitao
    Tong, Tianhong
    He, Yang
    Liang, Dongtai
    IEEE SENSORS LETTERS, 2024, 8 (11)
  • [2] Low-cost high-fidelity anaesthetic simulation
    Hartwell, D. A.
    Grayling, M.
    Kennedy, R. R.
    ANAESTHESIA AND INTENSIVE CARE, 2014, 42 (03) : 371 - 377
  • [3] A low-cost high-fidelity model for abscess simulation
    Done, Aaron J.
    Fairres, Marshall J.
    Heiler, Joseph C.
    Smith, Cody J.
    Rappaport, William
    AMERICAN JOURNAL OF SURGERY, 2020, 219 (04): : 628 - 631
  • [4] A versatile low-cost, high-fidelity cystoscopy simulation
    Igeh, A.
    Maldonado, P. A.
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2022, 226 (03) : S1345 - S1345
  • [5] Development of a Low-cost, High-fidelity Skin Model for Suturing
    Williams, Taylor P.
    Snyder, Clifford L.
    Hancock, Kevin J.
    Iglesias, Nicholas J.
    Sommerhalder, Christian
    DeLao, Shannon C.
    Chacin, Aisen C.
    Perez, Alexander
    JOURNAL OF SURGICAL RESEARCH, 2020, 256 : 618 - 622
  • [6] Low cost actuator and sensor for high-fidelity haptic interfaces
    Lawrence, DA
    Pao, LY
    White, AC
    Xu, WB
    12TH INTERNATIONAL SYMPOSIUM ON HAPTIC INTERFACES FOR VIRTUAL ENVIRONMENT AND TELEOPERATOR SYSTEMS, PROCEEDINGS, 2004, : 74 - 81
  • [7] A Low-Cost, High-Fidelity Simulator for Transabdominal Chorionic Villus Sampling
    Lord, Megan G.
    Esposito, Matthew A.
    Gimovsky, Alexis C.
    Carr, Stephen R.
    Russo, Melissa L.
    FETAL DIAGNOSIS AND THERAPY, 2024, 51 (02) : 101 - 111
  • [8] Creating a high-fidelity, low-cost cricoid pressure training device
    Duke, N.
    Parson, M.
    ANAESTHESIA, 2016, 71 : 78 - 78
  • [9] Development of a Low-cost High-fidelity Simulator for Search and Rescue Robot
    Han, Zhenfeng
    Zhao, Jie
    2009 WRI WORLD CONGRESS ON SOFTWARE ENGINEERING, VOL 3, PROCEEDINGS, 2009, : 217 - 221
  • [10] HIGH-FIDELITY DIGITAL AUDIO CONVERSION USING LOW-COST COMPONENTS
    WOOD, KJ
    HAWKSFORD, MJ
    JOURNAL OF THE AUDIO ENGINEERING SOCIETY, 1980, 28 (05): : 372 - &