Experimental Verification of Reinforced Concrete Pile Caps

被引:0
|
作者
Abdul-Razzaq, Khattab Saleem [1 ]
Farhood, Mustafa A. [1 ]
Jalil, Ali Mustafa [1 ]
机构
[1] Univ Diyala, Khan Bani Saad, Diyala, Iraq
关键词
Experimental verification; Reinforced concrete; Pile caps; STM;
D O I
10.1007/978-3-030-32816-0_65
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper deals with the experimental verification of the conventional design of pile caps, ACI 318-14, chapter thirteen. Six reinforced concrete pile cap specimens were designed according to the conventional theory, constructed, tested till failure, and then, compared to the theoretical design ones. The six specimens were divided into two groups; group A in which the spacing between piles was 270 mm, and group B; in which the spacing between piles was 410 mm. Every group contained three pile cap specimens, which were; two pile-cap specimens, three pile-cap specimens and four pile-cap specimens. The two pile-caps were 700 mm in length, 270 mm in height and 240 mm in width, while the three pile-caps were 586 mm in length, 270 mm in height and 700 mm in width. The four pile-caps were 700 mm in length, 270 mm in height and 700 mm in width. It is found that the experimental loads were higher than the design theoretical loads by (180-220)%. That takes place because the conventional method deals with Bernoulli region, while the pile cap is deep. In addition, ACI-318 procedures do not take into consideration the longitudinal reinforcement amount and overemphasize the role of the effective depth.
引用
收藏
页码:879 / 895
页数:17
相关论文
共 50 条
  • [31] STRUCTURAL ASSESSMENT OF THICK REINFORCED-CONCRETE PILE CAPS USING 1/5 SCALE MODELS
    SABNIS, GM
    DAGHER, RE
    LIFE OF STRUCTURES: PHYSICAL TESTING, 1989, : 172 - 180
  • [32] Three-dimensional nonlinear finite element analysis for steel reinforced concrete five pile caps
    Chen, Xizi
    Sun, Chengfang
    Peng, Shaomin
    Wuhan Ligong Daxue Xuebao/Journal of Wuhan University of Technology, 2002, 24 (12):
  • [33] Flexural stiffness of reinforced concrete columns and beams: Experimental verification
    Khuntia, M
    Ghosh, SK
    ACI STRUCTURAL JOURNAL, 2004, 101 (03) : 364 - 374
  • [34] Experimental Verification of Reinforced Concrete Member under Cyclic Loading
    Cavojcova, Alena
    Moravcik, Martin
    Bahleda, Frantisek
    Jost, Jozef
    XXIII R-S-P SEMINAR, THEORETICAL FOUNDATION OF CIVIL ENGINEERING (23RSP) (TFOCE 2014), 2014, 91 : 262 - 267
  • [35] Study on the Influence Factors of Bearing Capacity of the Fiber Reinforced High Strength Concrete Three-Pile Caps
    Lei, Jie
    Gao, DanYing
    Fan, Hua
    ADVANCES IN STRUCTURES, PTS 1-5, 2011, 163-167 : 1586 - 1591
  • [36] FINITE ELEMENT ANALYSIS OF LOAD-TRANSFERRED MODEL OF THE REINFORCED CONCRETE TWO-PILE THICK CAPS
    Sun, Cheng-Fang
    Gu, Qian
    Zhang, Yuan-Yuan
    Qin, Huai-Quan
    Peng, Shao-Min
    PROCEEDINGS OF THE TENTH INTERNATIONAL SYMPOSIUM ON STRUCTURAL ENGINEERING FOR YOUNG EXPERTS, VOLS I AND II, 2008, : 292 - 297
  • [37] AN EXPERIMENTAL INVESTIGATION OF THE EARTH-RESISTANCE RESPONSE OF A REINFORCED-CONCRETE PILE
    MCCARTER, WJ
    WHITTINGTON, HW
    FORDE, MC
    PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS PART 2-RESEARCH AND THEORY, 1981, 71 (DEC): : 1101 - 1129
  • [38] Experimental study of failure mechanism of thick pile caps
    Wang, Tan
    Dou, Lijun
    Yin, Kun
    4TH INTERNATIONAL CONFERENCE ON ADVANCED COMPOSITE MATERIALS AND MANUFACTURING ENGINEERING 2017, 2017, 207
  • [39] Experimental study on four-pile caps with taper
    Suzuki, Kuniyasu
    Otsuki, Kazuo
    Tsubata, Takuya
    Transactions of the Japan Concrete Institute, 1999, 21 : 327 - 334
  • [40] Experimental verification of functionality of fibre-reinforced concrete submersible piers
    Buchlak, J.
    Matejka, J.
    Ryjacek, P.
    Bily, P.
    Prochazka, J.
    Pollert, J.
    Fabel, J.
    FIBRE CONCRETE 2019, 2019, 596