Experimental Verification of Reinforced Concrete Pile Caps

被引:0
|
作者
Abdul-Razzaq, Khattab Saleem [1 ]
Farhood, Mustafa A. [1 ]
Jalil, Ali Mustafa [1 ]
机构
[1] Univ Diyala, Khan Bani Saad, Diyala, Iraq
关键词
Experimental verification; Reinforced concrete; Pile caps; STM;
D O I
10.1007/978-3-030-32816-0_65
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper deals with the experimental verification of the conventional design of pile caps, ACI 318-14, chapter thirteen. Six reinforced concrete pile cap specimens were designed according to the conventional theory, constructed, tested till failure, and then, compared to the theoretical design ones. The six specimens were divided into two groups; group A in which the spacing between piles was 270 mm, and group B; in which the spacing between piles was 410 mm. Every group contained three pile cap specimens, which were; two pile-cap specimens, three pile-cap specimens and four pile-cap specimens. The two pile-caps were 700 mm in length, 270 mm in height and 240 mm in width, while the three pile-caps were 586 mm in length, 270 mm in height and 700 mm in width. The four pile-caps were 700 mm in length, 270 mm in height and 700 mm in width. It is found that the experimental loads were higher than the design theoretical loads by (180-220)%. That takes place because the conventional method deals with Bernoulli region, while the pile cap is deep. In addition, ACI-318 procedures do not take into consideration the longitudinal reinforcement amount and overemphasize the role of the effective depth.
引用
收藏
页码:879 / 895
页数:17
相关论文
共 50 条
  • [21] Locking beam influence on behavior of reinforced concrete two pile caps with embedded socket
    Barros, Rodrigo
    Giongo, Jose Samuel
    ACTA SCIENTIARUM-TECHNOLOGY, 2014, 36 (02) : 211 - 220
  • [22] Experimental Analyses of Dynamic Damage of the Reinforced Concrete Pile
    Li, RongJian
    Yan, Rui
    Li, HaiTao
    PROGRESS IN INDUSTRIAL AND CIVIL ENGINEERING, PTS. 1-5, 2012, 204-208 : 3182 - 3185
  • [23] Analysis of two reinforced concrete pile caps with embedded sockets in the presence of a locking beam
    Barros, Rodrigo
    REM-REVISTA ESCOLA DE MINAS, 2010, 63 (03) : 597 - 598
  • [24] Experimental study on restoring force of reinforced concrete pile
    Maki, Takeshi
    Mutsuyoshi, Hiroshi
    Sasaki, Mitsunori
    Transactions of the Japan Concrete Institute, 2000, 22 : 279 - 286
  • [25] Experimental study and theoretic analysis of steel fiber reinforced concrete six-pile thick caps with double-column
    Li, Jixiang
    Zhang, Yuanyuan
    Liu, Xiaofan
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2009, 30 (02): : 149 - 157
  • [26] Transfer Mechanism of Steel Fiber Reinforced High Strength Concrete Three-pile Caps
    Gao, Danying
    Hai, Hui
    Lei, Jie
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 981 - 987
  • [27] NONLINEAR FINITE-ELEMENT ANALYSIS OF REINFORCED-CONCRETE 4-PILE CAPS
    SAM, C
    IYER, PK
    COMPUTERS & STRUCTURES, 1995, 57 (04) : 605 - 622
  • [28] Softened Strut-and-Tie Model for Shear and Flexural Strengths of Reinforced Concrete Pile Caps
    Mogili, Srinivas
    Hwang, Shyh-Jiann
    JOURNAL OF STRUCTURAL ENGINEERING, 2021, 147 (11)
  • [29] Flexural modeling of reinforced concrete walls - Experimental verification
    Orakcal, K
    Wallace, JW
    ACI STRUCTURAL JOURNAL, 2006, 103 (02) : 196 - 206
  • [30] Cracking in reinforced concrete bent caps
    Young, BS
    Bracci, JM
    Keating, PB
    Hueste, MBD
    ACI STRUCTURAL JOURNAL, 2002, 99 (04) : 488 - 498