MEASUREMENT AND COMPARISON OF MULTI-ELECTRODE PLACEMENT FOR BIOELECTRICAL IMPEDANCE ANALYSIS

被引:0
|
作者
West, Daniel [1 ]
Choi, JungHun [1 ]
机构
[1] Georgia Southern Univ, Dept Mech Engn, Statesboro, GA 30459 USA
关键词
Bioelectrical Impedance Spectroscopy; Cole-Cole Plot; Body Composition; Electrical Impedance Myography;
D O I
10.1115/DMD2019-3265
中图分类号
Q813 [细胞工程];
学科分类号
摘要
The purpose of this examination was to determine a) how bioimpedance scanning generates data about the human body and b) compare the Bodystat Multiscan 5000 and the Skulpt Chisel. The Bodystat Multiscan 5000 is bioelectrical impedance spectroscopy (BIS) device that performs a scan of 50 measurements, from 5 kHz to 1000 kHz. This scan generates a 2d Cole analysis plot that compares the resistance and reactance of the scanned muscle group. Higher frequencies measure the amount of intracellular fluid (ICF), and lower frequencies measure the amount of extracellular fluid (ECF). Lower values for the resistance and reactance relate to a greater level of fitness for the scanned area. The Skulpt Chisel is an electrical impedance myography (EIM) that performs a single 50 kHz measurement. This scan determines the muscle quality and percent body fat of the scanned muscle group. The test subject was scanned with each device. Each plane was scanned three times with the Bodystat Multiscan 5000, and scanned five times with the Skulpt Chisel. The data was recorded to Excel and analyzed using MATLAB. The Bodystat Multiscan measurements for the surfaces were examined at a frequency of 50 kHz to be comparable to the Skulpt Chisel data. The surfaces are recorded in descending order of magnitude for resistance: medial, 22.14 Omega; anterior, 20.31 Omega; posterior, 17.89 Omega, lateral, 12.6 Omega. The Cole Analysis for the right thigh at 45-degree intervals are recorded in descending order of magnitude for resistance: medial/posterior, 23.89 Omega; posterior/lateral, 23.06 Omega; anterior/medial, 21.09 Omega, lateral/anterior, 16.13 Omega. The Skulpt Chisel surfaces are recorded in an increasing order of magnitude, the first value being muscle quality and the second value being percent body fat: lateral, 81.12, 13.1%; posterior, 62.22, 16.46%; anterior, 50.88, 19.24%; medial, 42.16, 23.16%. The data display an inverse relationship between resistance/reactance and muscle quality, and a direct relationship between resistance/reactance and percent body fat. The larger the magnitude of the resistance/reactance recorded for a muscle group, the lower the level of muscle quality will be. This leads to a larger percent body fat value.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] ELECTRODE PLACEMENT IN NEONATAL BIOELECTRICAL-IMPEDANCE ANALYSIS
    SIDHU, JS
    TRIGGS, EJ
    CHARLES, BG
    TUDEHOPE, DI
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1994, 32 (04) : 456 - 459
  • [2] Simultaneous measurement of the botanical tissue impedance and the electrode impedance by the multi-electrode method
    Fukuma, H
    Tanaka, K
    Yamaura, I
    IMTC/2000: PROCEEDINGS OF THE 17TH IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE: SMART CONNECTIVITY: INTEGRATING MEASUREMENT AND CONTROL, 2000, : 956 - +
  • [3] Electrode placement for multifrequency bioelectrical impedance analysis: Proximal or distal electrodes?
    Meister, D
    Keller, W
    Ghosh, S
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2000, 59 : 139A - 139A
  • [5] Field analysis and electrical models of multi-electrode impedance sensors
    Szczepanik, Zdzislaw
    Rucki, Zbigniew
    SENSORS AND ACTUATORS A-PHYSICAL, 2007, 133 (01) : 13 - 22
  • [6] Validation Of A Multi-electrode Bioelectrical Impedance Analyzer With A Dual-energy X-ray Absorptiometer
    Meier, Nathan
    Bai, Yang
    Lee, Duck-chul
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 1050 - 1050
  • [7] Salt and moisture content determination of fish by bioelectrical impedance and a needle-type multi-electrode array
    Curic, Tomislav
    Radovcic, Nives Marusic
    Janci, Tibor
    Lackovic, Igor
    Vidacek, Sanja
    INTERNATIONAL JOURNAL OF FOOD PROPERTIES, 2017, 20 (11) : 2477 - 2486
  • [8] Performance evaluation of the electrode configuration in bioelectrical impedance analysis for visceral fat measurement
    Kim, Kwangsoo
    Lee, Mi-hee
    Kim, Jungchae
    Jung, Seok Myung
    Jee, Sun Ha
    Yoo, Sun K.
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 892 - +
  • [9] Multi-Electrode Impedance Method for Detection of Regional Ventilation
    Furuya, Norio
    Sakamoto, Katsuyuki
    XV INTERNATIONAL CONFERENCE ON ELECTRICAL BIO-IMPEDANCE (ICEBI) & XIV CONFERENCE ON ELECTRICAL IMPEDANCE TOMOGRAPHY (EIT), 2013, 434
  • [10] IMPORTANCE OF ELECTRODE POSITION IN BIOELECTRICAL IMPEDANCE ANALYSIS
    GARTNER, A
    MAIRE, B
    DELPEUCH, F
    SARDA, P
    DUPUY, RP
    RIEU, D
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1992, 56 (06): : 1067 - 1068