Study of water accumulation dynamics in the channels of an open-cathode fuel cell through electro-thermal characterisation and droplet visualisation

被引:38
|
作者
Obeisun, Oluwamayowa A. [1 ]
Meyer, Quentin [1 ]
Engebretsen, Erik [1 ]
Finegan, Donal P. [1 ]
Robinson, James B. [1 ]
Hinds, Gareth [2 ]
Shearing, Paul R. [1 ]
Brett, Daniel J. L. [1 ]
机构
[1] UCL, Dept Chem Engn, Electrochem Innovat Lab, London WC1E 7JE, England
[2] Natl Phys Lab, Teddington TW11 0LW, Middx, England
基金
英国工程与自然科学研究理事会;
关键词
Open-cathode fuel cell; Fuel cell orientation; Temperature mapping; Electrochemical impedance spectroscopy; Fuel cell gravimetric analysis; Water management; PRINTED-CIRCUIT BOARD; LIQUID WATER; TEMPERATURE DISTRIBUTION; RELATIVE-HUMIDITY; DIFFUSION LAYERS; FLOW CHANNELS; 2-PHASE FLOW; PEMFC; EXCHANGE; PERFORMANCE;
D O I
10.1016/j.ijhydene.2015.07.066
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Open-cathode polymer electrolyte fuel cells have the advantage of simplified construction and the potential for cost reduction. However, effective water and temperature management calls for a different approach to conventional fuel cells. Improved understanding of the link between current density, temperature, water formation and hydration of the membrane is required to optimise cell design. This work uses thermal imaging, optical visualisation, gravimetric analysis and electrochemical impedance spectroscopy to study the links between these factors and also examines the effect of cell orientation on performance. The results reinforce the importance of cell temperature for water management, which is a function of current density. Regions of the cell with higher temperature avoid flooding by promoting vapour phase water; however, this can lead to higher membrane resistance due to dehydration. The results reveal that transition in the water balance regime from continuous hydration and flooding to drying with increasing current density occurs between 34 degrees C-40 degrees C (at 250 mA cm(-2)) and water generation is balanced with evaporation at similar to 50 degrees C (550 mA cm(-2)). Finally, fuel cell orientation affects performance after extended operation due to the effect of water accumulation and evaporation, with the cathode in a 'flat upwards' orientation found to be most resistant to flooding and cathode in a flat downwards orientation the most likely to flood. Copyright (C) 2015, Hydrogen Energy Publications, LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:16786 / 16796
页数:11
相关论文
共 44 条
  • [41] Cell and stack-level study of steady-state and transient behaviour of temperature uniformity of open-cathode proton exchange membrane fuel cells
    Huang, Bi
    Jian, Qifei
    Luo, Lizhong
    Zhao, Jing
    Huang, Zipeng
    Wang, Xiaojun
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (14) : 8148 - 8163
  • [42] Development and experimental validation of a dynamic thermal and water distribution model of an open cathode proton exchange membrane fuel cell
    Strahl, Stephan
    Husar, Attila
    Serra, Maria
    JOURNAL OF POWER SOURCES, 2011, 196 (09) : 4251 - 4263
  • [43] Liquid water quantification in the cathode side gas channels of a proton exchange membrane fuel cell through two-phase flow visualization
    Banerjee, Rupak
    Kandlikar, Satish G.
    JOURNAL OF POWER SOURCES, 2014, 247 : 9 - 19
  • [44] Effect of gas diffusion layer properties on water distribution across air-cooled, open-cathode polymer electrolyte fuel cells: A combined ex-situ X-ray tomography and in-operando neutron imaging study
    Meyer, Quentin
    Ashton, Sean
    Boillat, Pierre
    Cochet, Magali
    Engebretsen, Erik
    Finegan, Donal P.
    Lu, Xuekun
    Bailey, Josh J.
    Mansor, Noramalina
    Abdulaziz, Rema
    Taiwo, Oluwadamilola O.
    Jervis, Rhodri
    Torija, Sergio
    Benson, Paul
    Foster, Simon
    Adcock, Paul
    Shearing, Paul R.
    Brett, Dan J. L.
    ELECTROCHIMICA ACTA, 2016, 211 : 478 - 487